Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 65-3
Publication Number: 53-1000242-01
TRCE-1006
65
TRCE-1006
Message
Probable
Cause
Indicates that a connectivity test to the FTP host has succeeded. This feature is enabled by the
supportFtp -t command.
Recommended
Action
No action is required.
Severity INFO
TRCE-1007
Message
Probable
Cause
Indicates that the active CP is unable to alert the standby CP of a change in trace status. This message is
only applicable to the SilkWorm 12000, 24000, and 48000.
Recommended
Action
This message is often transitory. Wait a few minutes and try the command again.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
TRCE-1008
Message
Probable
Cause
Indicates that the active CP is unable to read stored trace parameters.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
Run traceFtp to set up for automatic FTP transfers.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
<timestamp>, [TRCE-1006], <sequence-number>,, INFO, <system-name>,
FTP Connectivity Test succeeded to FTP site ' <FTP target configured
by users.> '.
<timestamp>, [TRCE-1007], <sequence-number>,, ERROR, <system-name>,
Notification of this CP has failed. Parameters temporarily out of
synch with other CP.
<timestamp>, [TRCE-1008], <sequence-number>, FFDC, CRITICAL,
<system-name>, Unable to load trace parameters.