Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 79-9
Publication Number: 53-1000242-01
SULB-1010
79
Recommended
Action
Run the firmwareDownloadStatus command for more information.
In a director, when firmwareDownload fails, the command will synchronize the firmware on the two
partitions of each CP by starting a firmware commit operation. Wait until this operation completes
(about 10 minutes) before attempting another firmwareDownload.
In a director, when firmwareDownload fails, the two CPs may end up with different versions of
firmware and they may not gain HA sync. In that case, run firmwareDownload single mode (-s) to
upgrade the firmware on the standby CP to the same version as the active CP. Then retry
firmwareDownload to download the desired version of firmware onto the CPs.
Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
Severity INFO
SULB-1010
Message
Probable
Cause
Indicates that the firmwareCommit failed. The error code provides debugging information. See
Table 79-3 for more information.
Recommended
Action
Run the firmwareCommit command with "-d" option to provide more debugging information.
Severity INFO
SULB-1017
Message
Probable
Cause
Indicates that the firmwareDownload failed in the indicated blade. The error can be caused by
inconsistent AP blade firmware stored on the active CP. It can also be caused by persistent storage
hardware failure.
SUS_PEER_FWC_BEGIN 0x32
SUS_PEER_FS_CHECK1 0x33
SUS_FINISH 0x34
SUS_COMMIT 0x35
Upgrade State Code
AUDIT, <timestamp>, [SULB-1010], INFO, FIRMWARE, <event-initiator-
details>, <event-location>, , Firmwarecommit failed
(status=0x<error code>).
AUDIT, <timestamp>, [SULB-1017], ERROR, FIRMWARE, <event-initiator-
details>, <event-location>, , Firmwaredownload failed in slot <Slot
number>.