Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

2-10 Fabric OS Message Reference
Publication Number: 53-1000242-01
AUTH-1031
2
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
AUTH-1031
Message
Probable
Cause
Indicates that the secret value was not set properly for the authenticated entity.
Recommended
Action
Reset the secret value by using secAuthSecret command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
Severity ERROR
AUTH-1032
Message
Probable
Cause
Indicates that the authentication process failed to generate a particular data (that is, challenge, nonce, or
response data) for an authentication payload. This usually relates to internal failure.
A nonce is a single-use, usually random value used in authentication protocols to prevent replay attacks.
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
<timestamp>, [AUTH-1031], <sequence-number>,, ERROR, <system-name>,
Failed to retrieve secret value: port <port number>
<timestamp>, [AUTH-1032], <sequence-number>,, ERROR, <system-name>,
Failed to generate <data type> for <message payload> payload:
length <data length>, error code <error code>, port <port number>