FRU monitoring
8
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [1]
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [1]
Power Supply Alarm Action: (0..17) [1]
Fan Alarm State: (0..31) [1]
Fan Alarm Action:(0..17) [1]
WWN Alarm State: (0..31) [1]
WWN Alarm Action: (0..31) [1]
SFP Alarm State: (0..31) [1]
SFP Alarm Action:(0..17) [1]
Fru configuration left unchanged
Specifying triggers for FRU alarms
You can specify triggers for any number of alarm states or alarm actions. The first prompt enables
you to select which FRU states trigger events.
1. Add the numbers beside each state (for the states you want to include).
2. Enter the total at the prompt.
For example, to trigger events using the Absent, Off, and Faulty states, add the assigned values and
enter that value at the prompt. In this case, the values are 1, 8, and 16, respectively, and the total
is 25.
Recommended FRU settings
Table 30 lists the recommended settings for field-replaceable units (FRUs).
TABLE 30 Recommended FRU settings
E=ERROR_LOG,
M=EMAIL_ALERT
Class Area Absent Inserted On Off Faulty Below Above
FRU Slot X X
Power Supply X X
Fan X X
WWN X X