Recommended settings for Fabric, SFP, Performance, Security classes
6
SFP Temperature X C None -10 85 3 X E E
RX power (RXP) X uWatts None 0 5000 25 X E E
TX power (TXP) X uWatts None 0 5000 25 X E E
Current X mA None 0 50 1 X E E
Voltage X uV None 2970 3630 10 X E E
PWR on Hours X Changes None 0 0 0 X
End-to-End
Performance
RX performance X KB/s None 0 0 0 X
TX performance X KB/s None 0 0 0 X
Filter-based
Performance
Custom filter
counter
XFrames None000X
Security Telnet violations X Violations Minute 1 2 0 X E,S
HTTP violations X Violations Minute 1 2 0 X E,S
SCC violations X Violations Minute 1 2 0 X E,S
DCC violations X Violations Minute 1 4 0 X E,S
Login violations X Violations Minute 1 2 0 X E,S
SLAP failures X Violations Minute 1 2 0 X E,S
TS out-of-sync X Violations Minute 1 2 0 X E,S
No FCS X Violations Minute 1 2 0 X E,S
Incompatible
security DB
X Violations Minute 1 2 0 X E,S
Illegal commands X Violations Minute 1 2 0 X E,S
TABLE 14 Recommended settings for Fabric, SFP, Performance, and Security classes (Continued)