FICON and CUP
In this chapter
•Introduction to FICON and CUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
•Identification of switches with FMS mode enabled . . . . . . . . . . . . . . . . . . 262
•Current port connectivity configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
•Stored port connectivity configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
•Port zone conflicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
•Insistent Domain ID mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
•Ports that completed the RNID exchange . . . . . . . . . . . . . . . . . . . . . . . . . . 268
•Link incidents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
•Cascaded FICON setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Introduction to FICON and CUP
FICON is a protocol used between IBM (and compatible) mainframes and storage.
FICON Control Unit Port (CUP) is a protocol for managing FICON directors. CUP is used by IBM
mainframe management applications to provide in-band management for ESCON and FICON. CUP
is an optional, license-based feature.
Host-based management programs manage the switches using CUP protocol by sending
commands to the emulated Control Device implemented by Fabric OS. A Brocade switch or director
that supports CUP can be controlled by one or more host-based management programs or director
consoles, such as Web Tools or Fabric Manager. The director allows control to be shared between
host-based management programs and director consoles.
To monitor a FICON CUP environment in Fabric Manager, you must have the following (all can be
performed through Web Tools):
• A CUP license installed on a FICON director
• FICON Management Server (FMS) mode enabled on the FICON director
• CUP attributes (FMS Parameters) configured for the FICON director
The following FICON Emulation features can be configured in Fabric Manager in the FCIP Tunnel
Configuration wizard:
• FICON XRC Emulation
• FICON Tape Write Emulation
• FICON Tape Read Emulation