Stored port connectivity configuration
19
Resolve any conflicts identified by the Analyze Zone Conflicts tool and repeat this step until no
further conflicts are identified.
4. Click Refresh to receive up-to-date information
5. Choose one of the following options.
Click Activate to activate the configuration that is currently displayed.
A confirmation dialog box displays.
a. Check the Active=Saved Mode check box if you want to save the FICON CUP port
connectivity configuration as an IPL file, in addition to activating the configuration. The
next time the switch reboots, it loads the configuration from this IPL file.
b. Click Yes to activate the displayed configuration.
Click No to close the dialog box without activating the configuration.
Click Save As to save the configuration as a file.
The configuration name must consist of only upper-case letters, digits, hyphen, and
underscore. If you use lower-case letters, they are converted to upper-case.
Click Cancel to close the dialog box.
Stored port connectivity configuration
This section describes how to view and edit stored port connectivity configurations. It also
describes how to activate a stored port connectivity configuration.
NOTE
You can activate a stored port connectivity configuration only for FMS-enabled switches running
Fabric OS v4.4.0 or later.
Users with roles of user or basicswitchadmin can only view the port connectivity configuration. Users
with the role of zoneadmin cannot access the port connectivity configuration. All other user roles can
view and modify the port connectivity configuration.
Editing a stored port connectivity configuration
1. In the View panel or Information panel, right-click a switch that has FMS mode enabled and
select PDCM Management > Stored from the context menu.
The FICON CUP Port Connectivity Configurations dialog box displays (see Figure 168).