Brocade Fabric Manager Administrator's Guide v6.1.0 (53-10000610-02, June 2008)

Fabric Manager Administrator’s Guide 277
53-10000610-02
About Fibre Channel routing
20
FIGURE 174 A metaSAN with edge-to-edge and backbone fabrics
For additional information about FC-FC routing, see the Fabric OS Administrator’s Guide.
Setting Up FC-FC routing
1. Ensure that the backbone fabric ID of the FC Router is the same as that of other FC Routers in
the backbone fabric.
2. On the FC Router, ensure that the ports to be configured as EX_Ports are either not connected
or are disabled.
3. Configure EX_Ports, as described in “Connect edge fabrics” on page 278. As part of this
configuration, supply a fabric ID for the fabric to which the port will be connected. You can
choose any unique fabric ID as long as it is consistent for all EX_Ports that connect to the same
edge fabric.
4. Connect the cables from the EX_Ports on the FC Router to the edge fabrics, if they are not
already connected.
5. Configure LSAN zones on the fabrics that will share devices. See “Device sharing between
fabrics” on page 280.
6. View the information in the LSAN View and the FCR Information to make sure that your
configuration has succeeded.
Edge Fabric 1
Backbone Fabric
Edge Fabric 3
Edge Fabric 2
IP Cloud
= LSAN
SilkWorm
7500
VEX_Port
VE_Port
EX_Port (2)
E_Port
E_Port
IFL
IFL IFL