Power-on firmware checksum test
FIPS requires the checksums of the executables and libraries on the filesystem to be validated before Fabric
OS modules are launched. This is to make sure these files have not been changed after they are installed.
When firmware RPM packages are installed during firmwareDownload, the MD5 checksums of the
firmware files are stored in the RPM database on the filesystem. This will go through all of the files in the
RPM database. Every file compares its current checksum with the checksum that is in the RPM database. If
they are different, the command will tell you.
Because the validation may take up to a few minutes, it will not be performed during hot code load. It is
only performed after a cold reboot of the switch.
For more information on FIPS, see ”Configuring advanced security features” on page 17.
Testing and restoring firmware on switches
Typically, users downgrade firmware after briefly evaluating a newer (or older) version and then restore the
original version of the firmware. Testing a new version of firmware in this manner ensures that you do not
replace existing firmware because the evaluated version occupies only one partition on the switch.
TIP: When you evaluate new firmware, make sure you disabled all features that are not supported by the
original firmware before restoring to the original version.
To test a different firmware version on a switch:
1. Verify that the FTP or SSH server is running on the host server and that you have a user ID on that
server.
2. Obtain the firmware file from the HP website at http://www.hp.com
and store the file on the FTP or
SSH server.
3. Unpack the compressed files preserving directory structures.
The firmware is in the form of RPM packages with names defined in a .plist file, that contains specific
firmware information and the names of packages of the firmware to be downloaded.
4. Connect to the switch and log in as admin.
5. Enter the firmwareShow command to view the current firmware.
6. Enter the firmwareDownload -s command to update the firmware and respond to the prompts as
follows:
switch:admin> firmwareDownload -s
Type of Firmware (FOS, SAS, or any application) [FOS]:
Server Name or IP Address: 192.168.32.10
Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]:
User Name: userfoo
File Name: /home/userfoo/5.3.0
Password:
Do Auto-Commit after Reboot [Y]: n
Reboot system after download [N]: y
Firmware is being downloaded to the switch. This step may take up to 30 minutes.
Checking system settings for firmwaredownload...
The switch will perform a reboot and come up with the new firmware to be tested. Your current switch
session will automatically disconnect.
7. Connect to the switch, log in as admin, and enter the firmwareShow command to confirm that the
primary partition of the switch contains the new firmware.
You are now ready to evaluate the new version of firmware.