HP StorageWorks Fabric OS 6.x administrator guide (5697-7344, March 2008)

238 Using the FC-FC routing service
9. Enter the cfgShow command to verify that the zones are correct.
switch:admin> cfgshow
Defined configuration:
zone: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c; 50:05:07:61:00:5b:62:ed;
50:05:07:61:00:49:20:b4
Effective configuration:
no configuration in effect
10. Enter the cfgAdd and cfgEnable commands to create and enable the LSAN configuration.
switch:admin> cfgadd "zone_cfg", "lsan_zone_fabric2"
switch:admin> cfgenable "zone_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'zone_cfg' configuration (yes, y, no, n): [no] y
zone config "zone_cfg" is in effect
Updating flash ...
11. Log in as an admin and connect to the 4/256 SAN Director or DC Director with a FR4-18i blade.
12. Enter the following commands to display information about the LSANs.
lsanZoneShow -s shows the LSAN.
switch:admin> lsanzoneshow -s
Fabric ID: 2 Zone Name: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c Imported
50:05:07:61:00:5b:62:ed EXIST
50:05:07:61:00:49:20:b4 EXIST
Fabric ID: 75 Zone Name: lsan_zone_fabric75
10:00:00:00:c9:2b:c9:0c EXIST
50:05:07:61:00:5b:62:ed Imported
fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin> fcrphydevshow
Device WWN Physical
Exists PID
in Fabric
-----------------------------------------
75 10:00:00:00:c9:2b:c9:0c c70000
2 50:05:07:61:00:5b:62:ed 0100ef
2 50:05:07:61:00:5b:62:ed 0100e8
Total devices displayed: 3
fcrProxyDevShow shows the proxy devices in the LSAN.
switch:admin> fcrproxydevshow
Proxy WWN Proxy Device Physical State
Created PID Exists PID
in Fabric in Fabric
----------------------------------------------------------------------------
75 50:05:07:61:00:5b:62:ed 01f001 2 0100e8 Imported
2 10:00:00:00:c9:2b:c9:0c 02f000 75 c70000 Imported
Total devices displayed: 2
On the 4/256 SAN Director or DC Director with an FR4-18i blade, the host and Target A are imported,
because both are defined by lsan_zone_fabric2 and lsan_zone_fabric75. However, target B defined by
lsan_zone_fabric75 is not imported because lsan_zone_fabric2 does not allow it.
When a PLOGI, PDISC, or ADISC arrives at the 4/256 SAN Director or DC Directory with an FR4-18i
blade, the SID and DID of the frame are checked. If they are LSAN-zoned at both SID and DID edge
fabrics, the frame will be forwarded to the DID. If they are not zoned, only the PLOGI is dropped; for the
remaining frames zoning enforcement takes place in the edge fabrics.