HP StorageWorks Fabric OS 6.x administrator guide (5697-7344, March 2008)

Fabric OS 6.x administrator guide 285
Configuring the server database
The Management Server database can be viewed or cleared. The command msPlClearDB is allowed
only in AD0 and AD255.
To view the contents of the Management Server database:
1. Connect to the switch and log in as admin.
2. Enter the msPlatShow command.
The contents of the Management Server platform database are displayed.
switch:admin> msplatshow
--------------------------------------------------
Platform Name: [9] "first obj"
Platform Type: 5 : GATEWAY
Number of Associated M.A.: 1
[35] "http://java.sun.com/products/plugin"
Number of Associated Node Names: 1
Associated Node Names:
10:00:00:60:69:20:15:71
--------------------------------------------------
Platform Name: [10] "second obj"
Platform Type: 7 : HOST_BUS_ADAPTER
Number of Associated M.A.: 1
Associated Management Addresses:
[30] "http://java.sun.com/products/1"
Number of Associated Node Names: 1
Associated Node Names:
10:00:00:60:69:20:15:75
To clear the Management Server database:
1. Connect to the switch and log in as admin.
2. Enter the msplClearDb command.
3. Enter y to confirm the deletion.
The Management Server platform database is cleared.
Controlling topology discovery
The topology discovery feature can be displayed, enabled, and disabled; it is disabled by default. The
commands mstdEnable and mstdDisable are allowed only in AD0 and AD255.
To display topology discovery status:
1. Connect to the switch and log in as admin.
2. Enter the mstdReadConfig command.
switch:admin> mstdreadconfig
*MS Topology Discovery is Enabled.
To enable topology discovery:
1. Connect to the switch and log in as admin.
2. Enter the mstdEnable command to enable the discovery feature locally.
3. Enter the mstdEnable all command to enable the discovery feature on the entire fabric.
switch:admin> mstdenable