HP StorageWorks Fabric OS 6.x administrator guide (5697-7344, March 2008)

Fabric OS 6.x administrator guide 459
FICON performance statistics
You can use the portShow fcipTunnel command to view the performance statistics and monitor the
behavior of an online FCIP tunnel. This additional information is reported in the details of the command
output.
portshow ficon [Slot/]ge0|ge1 all|tunnel_id [arguments]
Where:
The following is an example.
Sprint113:root> portshow ficon ge0 all
Port: ge0
VE_STATUS
TunnelId vePort vePortStatus veFeatureBitMap veHashEntryCount
0 ff DOWN 0 0
1 ff DOWN 0 0
2 ff DOWN 0 0
3 ff DOWN 0 0
4 ff DOWN 0 0
5 ff DOWN 0 0
6 ff DOWN 0 0
7 ff DOWN 0 0
FEATURES
TunnelId XRC TapeWrt TapeRd TinTir DvcLack RdBlkId
0 OFF OFF OFF OFF OFF OFF
1 OFF OFF OFF OFF OFF OFF
slot The slot number of a blade in a multi-slot chassis. Does not apply to
the 400 Multi-protocol Router.
ge0|ge1 The Ethernet port (ge0 or ge1).
tunnel_id Tunnel number (0-7).
arguments are
as follows:
-globals General FICON Controls/Statistics.
-images Discovered Images (FCUB).
-emul Emulated FDCBs.
-active Active FDCBs.
-epcb Emulation Control Block (port specific).
-fhpb FICON Host Path Block.
-fdpb adrs FICON Device Path Block.
-fchb FICON Channel Control Block.
-fcub FICON Control Unit Control Block.
-fdcb adrs FICON Device Control Block.
-mem adrs Display 1250 memory in 256 byte increments.
-pools Display current data buffer pool counts.
-pmmr Displays PMMR pointers.
-clear Clears statistics.