HP StorageWorks Fabric OS 6.x administrator guide (5697-7344, March 2008)

Fabric OS 6.x administrator guide 461
Where:
Hd - Hd is the hex value for the Host Domain (the entry domain for this host port into the fabric)
Hp - is the hex value for the Host Port (the entry port of this host connection into the fabric)
Dd - is the hex value for the Device Domain (the entry domain for this device into the fabric)
Dp - is the hex value for the Device Port (the entry port for this device connection into the fabric)
Lp - is the Logical Partition (LPAR) value for the host accessing the specific device. This could also be
called CH or FICON Channel Number.
Cu - is the Control Unit number (CUADDR) for the specific FICON connection
Dv - is the Device Number of this FICON connected device.
FC fastwrite concepts
FC fastwrite operates in Fibre Channel network topologies similar to the basic topology shown in
Figure 43. FC fastwrite provides accelerated speeds for SCSI Write operations over long distance Fibre
Enable Enable traces for a tunnel.
Filter Display the active trace filters.
Help Display this menu.
HEX Display traces in HEX.
INDex xx Display traces starting at index 'xx'.
INOxid 0-FFFF Set/Reset the inbound FC OXID filter.
Lcontrol Set/Reset the FICON link control frame filter.
N Display the next trace records.
NCfg Display a new FCTRACE configuration.
OUtoxid 0-FFFF Set/Reset the outbound FC OXID filter.
OXid 0-FFFF Set/Reset the inbound and outbound FC OXID filters.
P Display the previous trace record.
PAGe n Set/Display the records per page to display.
PATh Set/Reset the path filter HdHpDdDpChCuDv
POSt 0-100 Set/Display the post trigger percentage.
RCtl 00-FF Set/Reset the FC R_CTL filter.
RECords Specify/Display the number of records per buffer.
RESet Reset all trace filters.
Rsize Specify the trace record size (80-240 bytes).
RXid 0-FFFF Set/Reset the FC frame RXID filter
SAVE n Save trace buffer n for a tunnel to non-volatile memory.
SCfg Display the FTRACE configuration saved in persistent storage.
STATS Display the FTRACE stats for a tunnel.
STATUs Set/Reset the FICON status frame filter.
T Display the top (oldest) trace records.
TImestamp Enable/Disable the timestamp display.
TOken 0-FFFFFF Set/Reset the FICON token filter.
TRAcemask Set/Display the trace mask (0-FFFFFFFF).
TRIGGER Display the first trigger point in the buffer.
TRIGGERMask Set/Display the trigger mask (0-FFFFFFFF).
TRIGGERS Set/Reset the triggered event filter.
TYpe 0-FF Set the FC frame TYPE frame filter.