HP Designjet T2500 eMFP - Image-quality troubleshooting guide
Clean the scanner’s glass plates
You are recommended to clean the scanner's glass plates periodically, depending on how often you use the
scanner.
1. Turn off the product using the Power key at the front, then also turn off the power switch at the rear
and disconnect the power cable.
2. There is a small lever at the rear left of the scanner. Slide the lever up and open the scanner cover.
WARNING! Do not lift the scanner while the scanner cover is open. Your fingers or hand may be
trapped or crushed.
3. Gently wipe the glass plates and the surrounding area with a lint-free cloth dampened with water and
then wrung dry. A suitable cloth is provided with the printer.
CAUTION: Do not use abrasives, acetone, benzene or fluids that contain these chemicals. Do not spray
liquids directly onto the scanner glass plates or anywhere else in the scanner.
Do not worry about tiny droplets of water left on the glass: they will evaporate.
4. Optionally, for more thorough cleaning:
●
Remove the glass plates and clean them on both sides. See users guide Replace the scanner’s glass
plates.
40 Chapter 4 Scanner maintenance ENWW