3.7.0 HP StorageWorks HP Scalable NAS File Serving Software upgrade guide HP Scalable NAS for Linux (AG513-96005, October 2009)

19. If you installed an HBA driver in the previous step, run the following command
to load it:
# /etc/init.d/pmxs load
Then run the following command to see a list of devices and review the output
to verify that the SAN is configured as you expect.
# cat /proc/partitions
20. Check the mount points for the PSFS filesystems on the server, and recreate them
if necessary to match the other servers.
21. Start HP Scalable NAS on the node:
# /etc/init.d/pmxs start
22. Repeat this procedure on the server with the next-highest IP address. Be sure to
skip step 16.
When all servers are upgraded, complete the post-upgrade steps described in Chapter
7, page 81.
HP Scalable NAS File Serving Software upgrade guide 69