3.7.0 HP StorageWorks HP Scalable NAS File Serving Software upgrade guide HP Scalable NAS for Linux (AG513-96005, October 2009)

Upgrade to the 3.7.0 release
Upgrade the first node
The server with the highest IP address should be upgraded first. Use this procedure
to upgrade the server.
NOTE:
Before starting the upgrade, back up any customizations, supporting application
settings, scripts (Samba scripts, event notifier scripts, and so on), and local changes
made to cluster configuration files. HP also recommends backing up all PSFS
filesystems.
1. Disable the server on the Management Console. (Select the server, right-click,
and select Disable.)
2. Back up the FS Option for Linux configuration and any quotas information on
PSFS filesystems. See Back up the cluster configuration, page 15.
3. Stop HP Clustered File System on the server:
# /etc/init.d/pmxs stop
4. Back up the cluster configuration on the server, as described under Back up the
cluster configuration, page 15. Also save the Samba configuration files (see
Samba configuration, page 16).
5. Perform a Quick Restore of the 3.7.0 release using the Quick Restore DVD. See
the HP StorageWorks X5500 Network Storage Gateway for Linux setup guide
for more information.
6. Configure the network interfaces on the server as they were before the upgrade.
7. The Quick Restore provides two versions of the fc_pcitable file, one for
ProLiant DL380 G4 servers and one for ProLiant DL380 G5 servers, with the
default being the G5 version. If this server is a ProLiant DL380 G4, rename the
files as follows:
# mv /etc/opt/hpcfs/fc_pcitable /etc/opt/hpcfs/fc_pcitable-G5
# mv /etc/opt/hpcfs/fc_pcitable-G4 /etc/opt/hpcfs/fc_pcitable
Upgrade HP Clustered Gateway/HP 4400 Scalable NAS systems74