HP StorageWorks Clustered File System 3.6.0 Windows Storage Server Edition Administration Guide (403103-005, January 2008)
Table Of Contents
- Contents
- HP Technical Support
- Quick Start Checklist
- Introduction to HP Clustered File System
- Cluster Administration
- Administrative Considerations and Restrictions
- Tested Configuration Limits
- Volume and Filesystem Limits
- User Authentication
- Start the Management Console
- Cluster Management Applications
- The HP CFS Management Console
- View Installed Software
- Start HP Clustered File System
- Stop HP Clustered File System
- Back Up and Restore the Cluster Configuration
- HP Clustered File System Network Port Numbers
- Configure Servers
- Configure Network Interfaces
- Configure the SAN
- Configure Dynamic Volumes
- Configure PSFS Filesystems
- Manage Disk Quotas
- Manage Hardware Snapshots
- Configure Security Features
- Configure Event Notifiers and View Events
- Overview
- Install and Configure the Microsoft SNMP Service
- Cluster Event Viewer
- Configure Event Notifier Services
- Select Events for a Notifier Service
- Configure the SNMP Notifier Service
- Configure the Email Notifier Service
- Configure the Script Notifier Service
- View Configurations from the Command Line
- Test Notifier Services
- Enable or Disable a Notifier Service
- Restore Notifier Event Settings to Default Values
- Import or Export the Notifier Event Settings
- Using Custom Notifier Scripts
- Cluster Operations on the Applications Tab
- Configure Virtual Hosts
- Configure Service Monitors
- Configure Device Monitors
- Advanced Monitor Topics
- SAN Maintenance
- Other Cluster Maintenance
- Management Console Icons
- Index
Chapter 17: Configure Device Monitors 223
Probe Type. The servers on which the monitor probe will occur. Select
Single-Probe to conduct the probe only on the server where the monitor is
active. Select Multi-Probe to conduct the probe on all servers configured
for the monitor.
Activity Type. Where the monitor can be active. The options are:
• Single-Active. The monitor is active on only one of the selected
servers. Upon server failure, the monitor will fail over to an active
server unless all associated service and device monitors are down.
(“Associated” service and device monitors are those monitors that are
associated with the same virtual host as this device monitor.)
• Single-Always-Active. The monitor is active on only one of the
selected servers. Upon server failure, the monitor will fail over to an
active server even if all associated service and device monitors are
down. (“Associated” service and device monitors are those monitors
that are associated with the same virtual host as this device monitor.)
• Multi-Active. The monitor is active simultaneously on all selected
servers. This option sets the probe type to Multi-Probe. The Selected
Servers column will not display P or B (for primary or backup).