HP StorageWorks Clustered File System 3.6.0 Windows Storage Server Edition Administration Guide (403103-005, January 2008)

Table Of Contents
Chapter 7: Configure the SAN 71
The options are:
Following are some examples of these options.
Show Partition Information
The -a option also lists the partitions on each disk. When combined with
-u, it displays partition information for unimported disks.
sandiskinfo -a
Disk: \\.\Global\psd1 (Membership Disk)
Uid: 20:00:00:04:cf:13:38:18::0 SAN info: fcswitch5:7
Vendor: SEAGATE Capacity: 34733M
partition 01: size 16M type (PSMP/Active)
partition 02: size 9398M type (PSMP/Inactive)
partition 03: size 16M type (PSMP/Inactive)
partition 04: size 9421M type
partition 05: size 16M type
partition 06: size 9421M type (PSFS Filesystem)
partition 07: size 1028M type
partition 08: size 1028M type (unknown)
Disk: \\.\Global\psd2
Uid: 20:00:00:04:cf:13:38:3a::0 SAN info: fcswitch5:7
Vendor: SEAGATE Capacity: 34733M
partition 01: size 9M type (PSMP/Active)
partition 02: size 097M type (PSFS Filesystem)
partition 03: size 97M type (PSFS Filesystem)
partition 04: size 9220M type (unknown)
-i Display information for imported disks (the default).
-u Display information for unimported disks.
-v Display available volumes.
-f Display PSFS filesystem volumes.
-a Display all information; for -v, display all known volumes.
-l Additionally display host-local device name.
-r Additionally display local device route information.
-U Display output in the format used by the HP Management
Console. This option is used internally by HP Clustered File
System and does not produce human-readable output.
-q Suppress output of all log messages.