A P P E N D I X E Running Diagnostics on the SA8250
327
Boot-time LED Diagnostics
The front panels Status, Act 1 and Act 2 LEDs display the transition
through a sequence of codes at boot time indicating the SA8250s
progress through the boot process. If the boot process aborts,
terminates, or hangs before the SA8250 is online and functional, the
state of the LEDs can help in diagnosing the problem. This table
describes the restart sequence and conditions.
After restart completes, the Status LED begins to blink and LED
activity begins as described in the next section, Run time LED
Diagnostics.
Run time LED Diagnostics
At run time, the LEDs provide this information about unit activity:
Status LED
Blinks on and off quickly when serving as the active or
standalone SA8250.
Blinks on and off slowly when configured for serial cable
failover and serving as the backup SA8250.
Continuous on or off indicates a unit that has stopped responding
(hung).
Status Act 1 Act 2 Condition
Off Off Off BIOS boot failed
On Off Off OS boot process failed
Off On Off OS boot stage 1 failed
On On Off OS boot stage 2 failed
Off Off On OS boot stage 3 failed
On Off On Application never started up
Off On On Application restart stage 1 failed
On On On Application restart stage 2 failed