HP e-Commerce / XML director server appliance sa8250 - Users Guide

C H A P T E R 3 HP e-Commerce/XML Director Server Appliance SA8250 User Guide
62
System
Requirements
You can use any terminal or workstation with a terminal emulator to
run Boot Monitor, provided the terminal has the following features:
9600 bits per second, 8 data bits, 1 stop bit no parity, no flow
control (9600-8-N-1)
A terminal emulation program, such as HyperTerminal*
Cable and connector to match the male DTE connector (DB-9)
Accessing the
Boot Monitor
You can access the Boot Monitor in either of the two ways described
below.
Interrupting the Bootup Sequence
1. Interrupt the SA8250's bootup sequence by pressing a key at the
following prompt:
Press any key to stop autoboot.
In a few seconds the following prompt displays, confirming that
the Boot Monitor is running:
monitor>
Using the Run Time CLI
1. Type this command at the prompt:
HP SA8250#config sys autoboot disable
2. Type this command at the prompt:
HP SA8250#reboot
The monitor> prompt displays, confirming that the Boot
Monitor is running.