HP e-Commerce / XML director server appliance sa8250 - Users Guide
C H A P T E R 3 HP e-Commerce/XML Director Server Appliance SA8250 User Guide
72
load Loads a previously saved configuration file into memory.
Example:
monitor>load
Select a configuration file to load from the
following files.
File name
--------------
active.cfg
backup.cfg
cris.cfg
‘active.cfg’ is the last booted configuration.
Enter the configuration filename to load
(- to cancel): [active.cfg] --->
Configuration loaded: active.cfg
netmask Sets the netmask.
Example:
monitor>netmask
Enter Netmask for Network side NIC
[255.255.255.0] --->
Enter Netmask for Service side NIC
[255.255.255.0] --->
rich-bias Optimizes RICH_HTTP service performance. If your RICH_HTTP
service responses consist mostly of files greater than 8K, the enabled
(default) setting of
rich_bias will optimize performance. If your
site is experiencing performance problems and the RICH_HTTP
service responses are less than 8K, you should disable
rich_bias.
This command has no effect on SSL terminated connections.
Example:
monitor>rich_bias
Unit is currently ‘RICH_Biased’, change it
(yes, no) [no] --->
yes
RICH_Biased (enable, disable) [enable]
--->
disable