HP StorageWorks Enterprise Modular Library E-Series Getting Started (AD560-96030, September 2007)

CAUTION! To avoid damaging Fibre Channel
(FC) cables, do not pinch or sharply bend the
cable tighter than a 5-centimeter (2-inch)
diameter. Allow a radial bend when attaching
an FC cable to a cable clip.
Connect the cables
At the back of the library, plug an FC cable (not
included) into the FC0 port on the interface controller
and plug the other end into either the host bus adapter
(HBA) port on the host or into an FC switch that is
connected to the host. Attach labels to each end of the
cable.
8
If your library contains LTO3 tape drives and a second
host is available, plug an FC cable (not included) into
the FC1 port on the interface controller and plug the
other end into the HBA port on the host or into an FC
switch that is connected to the host. Attach labels to
each end of the cable.
9
To host
To host
e2400-FC 2Gb
interface controller
e2400-FC 2Gb
interface controller
e2400-FC 4Gb
interface controller
e2400-FC 4Gb
interface controller
Plug one end of an Ethernet cable (not included) into
the NETWORK port on the Interface Manager card and
plug the other end into the Ethernet port on your
management station.
TO FIBRE CHANNEL CONTROLLERS NETWORK SERIAL AUX STATUS
ERROR
10
To management station
Interface Manager card
LTO4 tape drives only
LTO3 tape drives only
11
For each LTO4 tape drive, plug one end of an FC cable
(not included) into Port A on the tape drive and plug the
other end into your SAN.
To SAN