HP StorageWorks Enterprise Modular Library E-Series Getting Started (AD560-96069, May 2010)

7 LTO3 tape drives only
If your library contains LTO3 tape drives and a second host is available,
plug an FC cable (not included) into the FC1 port on the interface
controller and plug the other end into the HBA port on the host or into
an FC switch that is connected to the host. Attach labels to each end of
the cable.
8 Connect ethernet cable
Plug one end of an Ethernet cable (not included) into the NETWORK
port on the Interface Manager card and plug the other end into the
Ethernet port on the customer LAN.
9 LTO4 and LTO5 tape drives only
For each LTO4 and LTO5 tape drive, plug one end of an FC cable (not
included) into Port A on the tape drive and plug the other end into your
SAN.
10 Plug in the power cable
If you have more than one power distribution unit (PDU), plug each PDU
power cable into a different AC power circuit to establish redundancy.
11 Cabling checklist
Verify that all cabling is correct. Look at the back of the library and
compare to one of the following drawings.
CAUTION:
Do not connect this switch to your local LAN. It is for internal
library communication only. Connecting this switch to a LAN
could cause library components to perform incorrectly or report
failures.
2. Library robotics controller1. Switch for the internal network
4. To host
3. e2400FC 2Gb interface con-
troller
6. To management station, via
customer LAN
5. Interface manager card
8. Tape drives7. Port A to SAN
10. To port 2 on the switch9. To port 1 on the switch
12. To port 4 on the switch11. To port 3 on the switch
Figure 1 LTO4 tape drives
.
Page 3