53-1002149-01 29 April 2011 Fabric OS Message Reference Supporting Fabric OS v7.0.
Copyright © 2002-2011 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCFM, DCX, Fabric OS, FastIron, IronView, NetIron, SAN Health, ServerIron, TurboIron, and Wingspan are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One, Extraordinary Networks, MyBrocade, VCS, and VDX are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
Title Publication number Summary of changes Date Diagnostic and System Error Message Reference v4.2.0 53-0000515-08 Update software and hardware support March 2004 Fabric OS System Error Message Reference Manual 53-0000515-09 Updated for v4.4.
Title Publication number Summary of changes Date Fabric OS Message Reference 53-1001116-01 Updated for Fabric OS v6.1.1_enc: -Revised and added new messages to AG -Added new chapters: CNM, CTAP, CVLC, CVLM, KAC, RKD, SPC, SPM -Added new Audit chapters: AG, FCIP, FICU, IPAD, PORT, SWCH, UCST -Updated Introductory chapters. Aug 2008 Fabric OS Message Reference 53-1001157-01 November 2008 Updated for Fabric OS v6.2.
Title Publication number Summary of changes Date Fabric OS Message Reference 53-1001767-01 Updated for Fabric OS v6.4.0: -Modified messages to FICU and FW -Deleted messages to BL, FCOE and FW -Added new messages to AG, AN, AUTH, BL, C2, CNM, CONF, CVLC, CVLM, FABR, FICU, FW, HAM, HIL, MQ, MS, MSTP, NS, NSM, ONM, PS, PSWP, RKD, SEC, SPM, SS, SSM, SULB, SWCH and ZONE. -Updated Introductory chapters. March 2010 Fabric OS Message Reference 53-1002149-01 April 2011 Updated for Fabric OS v7.0.
vi Fabric OS Message Reference 53-1002149-01
Contents About This Document In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxxi Document conventions . . . . .
System module descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Section I Chapter 2 RASLog Messages AG System Messages AG-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 AG-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 AG-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AG-1033. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 AG-1034. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AG-1035. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AG-1036. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 AG-1037 . . . .
AUTH-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 AUTH-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 AUTH-1007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 AUTH-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 AUTH-1010. . . . . . . . .
AUTH-1047. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Chapter 6 BKSW System Messages BKSW-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Chapter 7 BL System Messages BL-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 BL-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BL-1032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 BL-1033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 BL-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 BL-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 BL-1036 . .
BM-1054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 BM-1055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 BM-1056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 BM-1058 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C3-1016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 C3-1017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 C3-1018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 C3-1019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 C3-1020. . .
CCFG-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 CCFG-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 CCFG-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 CCFG-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 CCFG-1012 . . . . . . . . . . . . .
CNM-1023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 CNM-1024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 CNM-1025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 CNM-1026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 CNM-1027 . . . . . . . . . . . .
CNM-1060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CNM-1061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CNM-1062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CNM-3001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CNM-3002 . . . . . . . . . . . .
CVLC-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 CVLC-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 CVLC-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 CVLC-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 CVLC-1007 . . . . . . . . . . .
CVLM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 CVLM-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 CVLM-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 CVLM-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154 CVLM-1006 . . . . . . . . . . . . .
CVLM-3027 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162 CVLM-3028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 Chapter 23 DAUTH System Messages DOT1-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165 DOT1-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EM-1019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 EM-1020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 EM-1028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 EM-1029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 EM-1031 . . . . . . . .
Chapter 26 ESS System Messages ESS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189 ESS-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189 ESS-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189 ESS-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FABR-1015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 FABR-1016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204 FABR-1017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204 FABR-1018. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204 FABR-1019. . . . . . . . . . .
Chapter 30 FABS System Messages FABS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215 FABS-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215 FABS-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215 FABS-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCOE-1010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229 FCOE-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229 FCOE-1013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229 FCOE-1014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229 FCOE-1015. . . . . . . . . . . .
Chapter 35 FCPD System Messages FCPD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239 FCPD-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239 FCPD-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239 Chapter 36 FCPH System Messages FCPH-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCR-1027. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 FCR-1028. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 FCR-1029. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 FCR-1030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251 FCR-1031. . . . . . . . . .
FCR-1071 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260 FCR-1072. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260 FCR-1073. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261 FCR-1074 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261 FCR-1075. . . . . . . . .
FICN-1017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 FICN-1018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272 FICN-1019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272 FICN-1020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272 FICN-1021 . . . . . . . . .
FICN-1054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282 FICN-1055 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282 FICN-1056 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .283 FICN-1057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .283 FICN-1058 . . . . . . . . .
FICN-1091 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293 FICN-1092 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .294 FICN-1093 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .294 FICN-1094 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .294 FICN-1095 . . . . . . . . .
FICU-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304 FICU-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304 FICU-1017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305 FICU-1018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305 FICU-1019 . . . . . . . . .
FSS-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 FSS-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 FSS-1009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 FSS-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 FSS-1011 . . . . . . .
FW-1050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .328 FW-1051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329 FW-1052 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329 FW-1053 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .329 FW-1054 . . . . . . . . . .
FW-1164 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340 FW-1165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341 FW-1166 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341 FW-1167 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341 FW-1168 . . . . . . . . . .
FW-1201 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .351 FW-1202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352 FW-1203 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352 FW-1204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352 FW-1205 . . . . . . . . . .
FW-1341 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .363 FW-1342 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .363 FW-1343 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364 FW-1349 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .364 FW-1350 . . . . . . . . . .
FW-1408 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375 FW-1424 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375 FW-1425 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376 FW-1426 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376 FW-1427 . . . . . . . . .
FW-1518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .386 FW-1519 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387 FW-1520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387 FW-1521 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .387 FW-1522 . . . . . . . . . .
HAM-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398 HAM-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399 HAM-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399 HAM-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399 HAM-1010 . . . . . . . . . . . .
HIL-1306 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 HIL-1307 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 HIL-1308 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 HIL-1309 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .412 HIL-1310 . . . . . .
Chapter 51 HSL System Messages HSL-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425 HSL-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425 HSL-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425 HSL-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IPAD-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .440 Chapter 57 IPS System Messages IPS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .441 IPS-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .441 IPS-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAC-1013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451 KAC-1014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .451 KAC-1015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .452 KAC-1016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LFM-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .466 LFM-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .466 Chapter 67 LOG System Messages LOG-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .467 LOG-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MCAST_SS-1020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .475 Chapter 70 MFIC System Messages MFIC-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 477 MFIC-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 477 MFIC-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MSTP-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .489 MSTP-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .489 MSTP-2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .489 MSTP-2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .490 MSTP-2003 . . . . . . . . . . . . .
NSM-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501 NSM-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501 NSM-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .501 NSM-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .502 NSM-1014 . . . . . . . . . . . .
PDM-1020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .511 PDM-1021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .511 PDM-1022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512 PDM-1023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512 PDM-1024 . . . . . . . . . . . .
PORT-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .524 PORT-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .524 PORT-1010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .525 Chapter 84 PS System Messages PS-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 87 RCS System Messages RCS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537 RCS-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537 RCS-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .537 RCS-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 92 RTWR System Messages RTWR-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549 RTWR-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549 RTWR-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .550 Chapter 93 SAS System Messages SAS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC-1040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .562 SEC-1041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .563 SEC-1042. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .563 SEC-1043. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .563 SEC-1044. . . . . . . . . .
SEC-1086. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .573 SEC-1087. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .573 SEC-1088. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .573 SEC-1089. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574 SEC-1090. . . . . . . . . .
SEC-1130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .583 SEC-1135. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .584 SEC-1136. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .584 SEC-1137. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .584 SEC-1138. . . . . . . . . .
SEC-1187. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .594 SEC-1188. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .594 SEC-1189. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .595 SEC-1190. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .595 SEC-1191. . . . . . . . . .
SEC-1317 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .605 SEC-1318. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .605 SEC-1319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .605 SEC-1320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .606 SEC-1321. . . . . . . . . .
SFLO-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .615 SFLO-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .615 SFLO-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .615 SFLO-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .616 SFLO-1006. . . . . . . . . . . .
SPC-2040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627 SPC-2041. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627 SPC-2042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .628 SPC-2043 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .628 SPC-2044 . . . . . . . . . . .
SPM-1016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .638 SPM-3001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SPM-3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SPM-3003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SPM-3004 . . . . . . . . . . . .
SS-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .648 SS-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .648 SS-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .649 SS-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .649 SS-1009. . . . . . . .
SSMD-1304 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659 SSMD-1305 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659 SSMD-1306 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659 SSMD-1307 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659 SSMD-1308 . . . . . . . . . . . . .
SULB-1030 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674 SULB-1031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674 SULB-1032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .675 SULB-1033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .675 SULB-1034 . . . . . . . . . . . .
SWCH-1021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .684 SWCH-1022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .685 Chapter 104 SYSC System Messages SYSC-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .687 SYSC-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRCK-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .697 TRCK-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .697 TRCK-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .698 TRCK-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .698 TRCK-1006 . . . . . . . . . . . . .
Chapter 113 WEBD System Messages WEBD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 WEBD-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 WEBD-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 WEBD-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XTUN-2025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .720 Chapter 115 ZEUS System Messages ZEUS-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .721 ZEUS-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .721 ZEUS-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZONE-1031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .734 ZONE-1032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .734 ZONE-1033 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .734 ZONE-1034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .735 ZONE-1035 . . . . . . . . . . . . .
AG-1036. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746 AG-1037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746 Chapter 119 AUDIT AN System Messages AN-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 747 AN-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CNM-3003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .759 CNM-3004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .760 CNM-3005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .760 CNM-3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .760 CNM-3007 . . . . . . . . . . . .
CVLM-3018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .769 CVLM-3019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .770 CVLM-3020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .770 CVLM-3021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .770 CVLM-3022 . . . . . . . . . . . . .
Chapter 130 AUDIT HTTP System Messages HTTP-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .783 HTTP-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .783 Chapter 131 AUDIT IPAD System Messages IPAD-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .785 Chapter 132 AUDIT MS System Messages MS-1027 . . . . . . . . . . . .
SEC-3009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .798 SEC-3010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .798 SEC-3011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .798 SEC-3012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .799 SEC-3013. . . . . . . . . . .
SEC-3050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .808 SEC-3051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .809 SEC-3061. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .809 SEC-3062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .809 SEC-3063 . . . . . . . . . . .
SPM-3020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .820 SPM-3021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .820 SPM-3022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .820 SPM-3023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .820 SPM-3024 . . . . . . . . . . . .
Chapter 140 AUDIT SWCH System Messages SWCH-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .837 SWCH-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .837 SWCH-1014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .837 Chapter 141 AUDIT UCST System Messages UCST-1021. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZONE-3023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .849 ZONE-3024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .849 ZONE-3025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lxxviii Fabric OS Message Reference 53-1002149-01
About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix • Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix • What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxxi • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxxiii • Notice to the reader . . . . . . . . . . . . .
• • • • • • • • • • • Brocade 5410 Brocade 5424 Brocade 5450 Brocade 5460 Brocade 5470 Brocade 5480 Brocade 6510 Brocade 7800 Brocade 8000 Brocade Encryption Switch Brocade DCX Backbone and Brocade DCX-4S Backbone - FC8-16 port blade FC8-32 port blade FC8-48 port blade FC8-64 port blade FC10-6 port blade FCOE10-24 DCX Blade FR4-18i router blade FS8-18 Encryption Blade FX8-24 DCX Extension Blade • Brocade DCX 8510-8 Backbone and Brocade DCX 8510-4 Backbone - FC8-64 port blade - FC16-32 port blade - FC16-
• FC4-16 • FC4-32 • FC4-48 What’s new in this document The following changes have been made since this document was last released: • Information that was added: - “AG System Messages” - “AN System Messages” - “ANV System Messages” - “BL System Messages” - “C2 System Messages” - “C3 System Messages” - “CAL System Messages” - “CDR System Messages” - “CEE CONFIG System Messages” - “ECC System Messages” - “EM System Messages” - “ESS System Messages” - “FABR System Messages” - “FCOE System Messages” - “FCPH Sy
- “PDM System Messages” “PS System Messages” “RAS System Messages” “RCS System Messages” “RTE System Messages” “SCN System Messages” “SEC System Messages” “SNMP System Messages” “SPM System Messages” “SS System Messages” “SSMD System Messages” “SULB System Messages” “SWCH System Messages” “VS System Messages” “XTUN System Messages” “ZEUS System Messages” “ZONE System Messages” “AUDIT ESS System Messages” “AUDIT MS System Messages” “AUDIT PMGR System Messages” “AUDIT RAS System Messages” • Information that
- “NSM System Messages” For further information about new features and documentation updates for this release, refer to the release notes. Document conventions This section describes text formatting conventions and important notice formats used in this document.
Command examples This book describes how to perform configuration tasks using the Fabric OS command line interface, but does not describe the commands in detail. For complete descriptions of all Fabric OS commands, including syntax, operand description, and sample output, see the Fabric OS Command Reference. Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
These references are made for informational purposes only. Corporation Referenced Trademarks and Products Microsoft Corporation Windows, Windows NT, Internet Explorer Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover Additional information This section lists additional Brocade and industry-specific documentation that you might find helpful. Brocade resources To get up-to-the-minute information, go to http://my.brocade.com to register at no cost for a user ID and password.
• Error numbers and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2. Switch Serial Number The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below.
Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
lxxxviii Fabric OS Message Reference 53-1002149-01
Chapter Introduction to System Messages 1 In this chapter • Overview of system messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Viewing and configuring system message logs . . . . . . . . . . . . . . . . . . . . . . . . 4 • Reading a RAS system message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 • Responding to a system message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 • System module descriptions. . . . . . . .
1 Overview of system messages • Trace dump, first-time failure detection capture (FFDC), and core dump files can be uploaded to the FTP server using the supportSave command. • It is recommended to configure the syslogd facility as a management tool for error logs. This is particularly important for dual-domain switches because the syslogd facility saves messages from two logical switches as a single file and in sequential order. Refer to “System logging daemon (syslogd)” on page 3 for more information.
Overview of system messages 1 Event auditing is a configurable feature, set to off by default. You must enable event auditing by configuring the syslog daemon to send the events to a configured remote host using the syslogIpAdd command. You can set up filters to screen out particular classes of events using the auditCfg command (the classes include zone, security, configuration, firmware, and fabric).
1 Viewing and configuring system message logs Port logs The Fabric OS maintains an internal log of all port activity. Each switch or logical switch maintains a log file for each port. Port logs are circular buffers that can save up to 8000 entries per logical switch. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device A-to-device B, and control information.
Viewing and configuring system message logs TABLE 2 1 Commands for viewing or configuring the system parameters and logs (Continued) Command Description errDump Displays the entire error log, without page breaks. Use the -r option to show the messages in reverse order, from newest to oldest. errFilterSet Sets an error severity filter for the system console. errShow Displays the entire error log, with page breaks. Use the -r option to show the messages in reverse order, from newest to oldest.
1 Viewing and configuring system message logs TABLE 2 Commands for viewing or configuring the system parameters and logs (Continued) Command Description traceDump Displays, initiates, or removes a Fabric OS module trace dump. traceTrig Sets, removes, or displays trace triggers. Viewing system messages from Web Tools To view the system message log for a switch from Web Tools, perform the following steps. 1. Launch Web Tools. 2. Select the desired switch from the Fabric Tree.
Viewing and configuring system message logs 1 Type to continue, Q to stop: 2004/07/28-17:04:59, [FSSM-1003], 2,, WARNING, switch, HA State out of sync Type to continue, Q to stop: 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: Clearing the system message log To clear the system message log for a particular switch instance, perform the following steps. 1.
1 Reading a RAS system message syslog.1 syslog.2 192.168.163.234 10.128.128.160 Reading a RAS system message This section provides information about reading system messages.
Reading a RAS system message TABLE 3 1 System message field description (Continued) Example Variable name Description (blank) Audit and/or FFDC/SLOT/CHASS IS/FID Flags For most messages, this field contains a space character (null value) indicating that the message is neither an AUDIT or FFDC message. Messages may contain the following values: AUDIT indicates that this message is for a security issue.
1 Reading a RAS system message The fields in the error message are described in Table 4. 10 TABLE 4 Audit message field description Example Variable name Description AUDIT Audit flag Identifies the message as an Audit message. 2005/12/10-09:54:03 Date and Time Stamp The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized time stamp format based on the “LOCAL” setting.
Responding to a system message 1 Message severity levels There are four levels of severity for messages, ranging from Critical (1) to Info (4). In general, the definitions are wide ranging and are to be used as general guidelines for troubleshooting. For all cases, you should look at each specific error message description thoroughly before taking action. System messages have the following severity levels.
1 Responding to a system message • Is the switch operational? • Assess impact and urgency: - Is the switch down? - Is it a standalone switch? - How large is the fabric? - Is the fabric redundant? • Run the errDump command on each logical switch. • Run the supportFtp command (as needed) to set up automatic FTP transfers, and then run the supportSave command.
System module descriptions 1 If a daemon fails to ping the SWD within the defined interval, or if the daemon terminates unexpectedly, then the SWD dumps information to the panic dump files, which helps to diagnose the root cause of the unexpected failure. Run the pdShow command to view these files or the supportSave command to send them to a host workstation using FTP. The panic dump files and core files are intended for support personnel use only.
1 System module descriptions TABLE 6 14 System module descriptions (Continued) System module Description BLL Bloom is the name of the application specific integrated circuit (ASIC) used as the building block for third-generation hardware platforms. BLS Fibre Channel over IP port configuration message over Brocade 7800 and FX8-24 blade. BM Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP).
System module descriptions TABLE 6 1 System module descriptions (Continued) System module Description FBC Firmware blade compatibility errors with the control processor (CP). FCIP Fibre Channel over IP port configuration messages over the Brocade 7500 and FR4-18i blade. FCMC Fibre Channel miscellaneous messages relate to problems with the physical layer used to send Fibre Channel traffic to and from the switch. FCOE FCoE error messages indicate problems with the FCoE module of the Fabric OS.
1 System module descriptions TABLE 6 16 System module descriptions (Continued) System module Description HMON Health monitor. HSL HSL error messages indicate problems with the Hardware Subsystem Layer of the Fabric OS. HTTP HTTP error messages. IBD This RASLog generates messages related to port restart failure. IBPD IBPD stands for iSCSI gateway daemon on a blade processor (BP). It manages iSCSI initiator access control, session authentication, and session/connection statistics.
System module descriptions TABLE 6 1 System module descriptions (Continued) System module Description KSWD (continued) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • KTRC Kernel RAS trace module. L2SYS L2SYS error messages indicate problems with the Layer 2 System manager that controls the Layer 2 forwarding engine and controls the learning/aging/forwarding functionality.
1 System module descriptions TABLE 6 18 System module descriptions (Continued) System module Description MCAST_SS The Multicast Sub-System messages indicate any problems associated with the Layer 2 and Layer 3 Multicast platform support, including allocation of global platform resources such as MGIDs, hardware acceleration resources for Multicast, and route programming into the hardware (Layer 2 EXM for IGMP Snooping for Fabric OS v7.0.0).
System module descriptions TABLE 6 1 System module descriptions (Continued) System module Description RCS The reliable commit service daemon generates log entries when it receives a request from the zoning, security, or management server for passing data messages to switches in the fabric. RCS then requests reliable transport write and read (RTWR) to deliver the message. RCS also acts as a gatekeeper, limiting the number of outstanding requests for the Zoning, Security, or Management Server modules.
1 System module descriptions TABLE 6 20 System module descriptions (Continued) System module Description SYSC System controller is a daemon that starts up and shuts down all Fabric OS modules in the proper sequence. SYSM General system messages. TAPE A kernel-space driver that handles all I/O operations aimed at Tape containers. TRCE RAS TRACE error messages.
Section RASLog Messages I This section provides the RASLog messages, including: • AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 • AN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 • ANV System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 • AUTH System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• FCPD System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FCPH System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FCR System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FICON System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FICU System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• MSTP System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • NBFS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • NS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • NSM System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • ONMD System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• WEBD System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • XTUN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • ZEUS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • ZOLB System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • ZONE System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter AG System Messages 2 AG-1001 Message , [AG-1001], ,, ERROR, , N_Port ID virtualization (NPIV) is not supported by fabric port connected to port . Probable Cause N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access Gateway is connected. Recommended Action • On switches running Fabric OS 6.
2 AG-1004 Severity WARNING AG-1004 Message , [AG-1004], ,, ERROR, , Invalid response to fabric login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch.
AG-1008 Recommended Action Severity 2 Check the connectivity between the Access Gateway N_Port and the fabric switch port. WARNING AG-1008 Message , [AG-1008], ,, WARNING, , Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates the fabric switch management server did not accept the N_Port Login (PLOGI) request sent by the Access Gateway.
2 AG-1011 AG-1011 Message , [AG-1011], ,, WARNING, , Sending FDISC failed on N_Port . Probable Cause Indicates there was a failure sending discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected to the Access Gateway.
AG-1015 Severity 2 INFO AG-1015 Message , [AG-1015], ,, WARNING, , Unable to find online N_Ports to connect to the fabric. Probable Cause Indicates either no other N_Port is configured or all N_Ports are currently offline. Recommended Action Check whether or not any other N_Port is configured.
2 AG-1019 Recommended Action Severity Run the switchShow command to display the status of all ports in the system. Run the portCfgShow command to display a list of ports currently configured as N_Ports. Ensure that the host is connected to an F_port. ERROR AG-1019 Message , [AG-1019], ,, WARNING, , Unable to failover N_Port . No other N Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported.
AG-1022 2 AG-1022 Message , [AG-1022], ,, INFO, , F_Port is failed over to its preferred N_Port . Probable Cause Indicates the specified F_Port is failing over to its preferred N_Port. Recommended Action Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping.
2 AG-1026 AG-1026 Message , [AG-1026], ,, WARNING, , Unable to handle the login request on port due to insufficient resources. Probable Cause Indicates there are insufficient resources. Recommended Action Run configure CLI on AG switch and increase the number of allowed logins on this port.
AG-1030 Severity 2 WARNING AG-1030 Message , [AG-1030], ,, WARNING, , N_Port ID: has been determined to be unreliable. Probable Cause Indicates that the port goes online and offline very often. Recommended Action No action is required.
2 AG-1034 Severity INFO AG-1034 Message , [AG-1034], ,, INFO, CFG, ,F_Port cannot accept any more logins () . Probable Cause Indicates that the F_Port has already logged in the maximum number of devices. Recommended Action No action is required. Severity INFO AG-1035 Message , [AG-1035], ,, INFO, CFG, ,Device cannot login as ALPA value not available ().
AG-1038 Recommended Action Severity 2 If the switchshow command on the connected fabric switch port displays 'Persistently disabled: Area has been acquired', then check the cabling on the AG. All trunked ports in a single trunk should belong to the same ASIC Port Group. INFO AG-1038 Message , [AG-1038], ,, ERROR, ,Elara Ports going to different fabrics, Check N Port . Probable Cause Indicates a misconfiguration.
2 AG-1041 AG-1041 Message , [AG-1041], ,, WARNING, , Static F-Ports mapped to N-Port are disabled as Trunking is enabled on the N_Port. Probable Cause Indicates that the trunk is enbled on the static N_Port. Recommended Action Delete static mapping on the AG using the ag --staticdel N-Port F-Port[s] command or disable the trunk on N_Port.
Chapter AN System Messages 3 AN-1001 Message , [AN-1001], ,, ERROR, , Failed to allocate memory: Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Restart or power cycle the switch.
3 AN-1004 AN-1004 Message , [AN-1004], ,, WARNING, FABRIC, , Congestion bottleneck on port /. pct. of secs. affected. Probable Cause Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
AN-1012 Recommended Action Severity 3 The port is recovered. No action is required. WARNING AN-1012 Message , [AN-1012], ,, WARNING, FABRIC, , Credits did not return from other end. Complete loss of credits on a VC on slot port . Probable Cause Indicates a credit loss. Recommended Action The port is recovered. No action is required.
3 40 AN-1013 Fabric OS Message Reference 53-1002149-01
Chapter ANV System Messages 4 ANV-1001 Message , [ANV-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between peer ports. Recommended Action Verify if you are using compatible SFPs on the peer ports. Verify that the SFPs have not deteriorated and the Fibre Channel cable is not faulty.
4 ANV-1004 ANV-1004 Message , [ANV-1004], ,, ERROR, , S,C: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x. Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Action Restart the system at the next maintenance window. If the problem persists, replace the blade.
ANV-1008 Severity 4 CRITICAL ANV-1008 Message , [ANV-1008], ,, ERROR, , S,C: MAC-VID classifier table is full. No space for new entry. Probable Cause Indicates that the MAC-VID classifier table is full and no more entries can be added. Recommended Action Delete some of the existing unused rules to add new entries.
4 44 ANV-1016 Fabric OS Message Reference 53-1002149-01
Chapter AUTH System Messages 5 AUTH-1001 Message , [AUTH-1001], ,, INFO, , has been successfully completed. Probable Cause Indicates that the secret database operation has been updated using the secAuthSecret command. The values for Operation type can be “set” or “remove”. Recommended Action No action is required.
5 AUTH-1004 AUTH-1004 Message , [AUTH-1004], ,, ERROR, , Failed to set type to . Probable Cause Indicates that the authUtil command has failed to set the authentication configuration value. The data type is either authentication type, DH group type, or policy type. Recommended Action Retry the authUtil command.
AUTH-1008 Recommended Action Severity 5 Run the authUtil command to make sure the local switch supports the specified protocols: Fibre channel authentication protocol (FCAP) or Diffie Hellman - challenge handshake authentication protocol (DH-CHAP). ERROR AUTH-1008 Message , [AUTH-1008], ,, ERROR, , No security license, operation failed. Probable Cause Indicates that the switch does not have a security license.
5 AUTH-1012 AUTH-1012 Message , [AUTH-1012], ,, WARNING, , Authentication is rejected: port explain reason . Probable Cause Indicates that an authentication is rejected because the remote entity does not support authentication. Recommended Action Make sure the entity at the other end of the link supports authentication.
AUTH-1016 5 AUTH-1016 Message , [AUTH-1016], ,, ERROR, , Invalid value to start HBA authentication port: , . Probable Cause This may relate to an internal failure. Recommended Action Copy the message, collect switch information using the supportShow command, and contact your switch service provider.
5 AUTH-1022 Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
AUTH-1025 5 If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1025 Message , [AUTH-1025], ,, ERROR, , Failed to get during : port . Probable Cause Indicates that the authentication process failed to get the expected information during the specified authentication phase.
5 AUTH-1028 Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message Probable Cause , [AUTH-1028], ,, ERROR, , Failed to allocate for : port .
AUTH-1030 5 AUTH-1030 Message , [AUTH-1030], ,, ERROR, , Invalid message code for message: port . Probable Cause Indicates the receiving payload does not have valid message code for a particular authentication phase. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands.
5 AUTH-1033 AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch . Probable Cause Indicates that an entity was not configured in the switch connection control (SCC) policy and tried to connect to the port.
AUTH-1036 5 AUTH-1036 Message , [AUTH-1036], ,, ERROR, , Invalid state for : port . Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands.
5 AUTH-1039 AUTH-1039 Message , [AUTH-1039], ,, ERROR, , Neighboring switch has conflicting authentication policy: Port disabled. Probable Cause Indicates that the neighboring switch has a conflicting authentication policy enabled. The_E-Port has been disabled, because the neighboring switch rejected the authentication negotiation, and the local switch has a strict switch authentication policy.
AUTH-1042 5 AUTH-1042 Message , [AUTH-1042], ,, ERROR, , Port has been disabled, because authentication failed with code '' and explanation ''. Probable Cause The specified port has been disabled, because the connecting switch/device failed to authenticate. The error might indicate that an invalid entity attempted to connect to the switch.
5 AUTH-1045 AUTH-1045 Message , [AUTH-1045], ,, ERROR, SECURITY, , Certificate not present in this switch in port . Probable Cause Indicates that the public key infrastructure (PKI) certificate is not installed in this switch. Recommended Action Check the certificate availability using the pkiShow command.
Chapter BKSW System Messages 6 BKSW-1003 Message Probable Cause , [BKSW-1003], , FFDC, WARNING, , kSWD: . Indicates a warning state within the system. A critical application error was reported in the watchdog subsystem. This message is used to convey information regarding the state of the system. Refer to the string at the end of the error message for specific information.
6 60 BKSW-1003 Fabric OS Message Reference 53-1002149-01
Chapter BL System Messages 7 BL-1000 Message , [BL-1000], ,, INFO, , Initializing ports... Probable Cause Indicates that the switch has started initializing the ports. Recommended Action No action is required. Severity INFO BL-1001 Message , [BL-1001], ,, INFO, , Port initialization completed. Probable Cause Indicates that the switch has completed initializing the ports.
7 BL-1003 Severity CRITICAL BL-1003 Message , [BL-1003], , FFDC, CRITICAL, , Faulting blade in slot . Probable Cause Indicates a faulty blade in the specified slot number. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade. Run the systemVerification command to verify that blade does not have hardware problems. To run this command root access is required.
BL-1007 7 BL-1007 Message , [BL-1007], ,, WARNING, , blade #: blade state is inconsistent with EM. bl_cflags 0x, slot_on , slot_off , faulty , status . Probable Cause Indicates that a failover occurred while a blade was initializing on the previously active control processor (CP). Recommended Action No action is required. The blade is reinitialized.
7 BL-1010 If the message persists, replace the blade. Severity CRITICAL BL-1010 Message , [BL-1010], ,, WARNING, , Blade in slot inconsistent with the hardware settings. Probable Cause Indicates that a failover occurred while some hardware changes were being made on the previously active control processor (CP) (such as changing the domain ID). Recommended Action No action is required. This blade has been reinitialized.
BL-1013 7 Probable Cause Indicates that the port generated an excessive number of interrupts that might prove unrecoverable to the switch operation. The port is disabled to prevent the control processor (CP) from becoming too busy. The bport is the blade port; this number might not correspond to a user port number. Recommended Action Make sure to capture the console output during this process. Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port.
7 BL-1015 Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the Brocade 3900, replace the motherboard FRU. • On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500, AP7600, and 5000, replace the switch.
BL-1017 7 Run the systemVerification command to verify that the blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1017 Message , [BL-1017], ,, INFO, , Slot Initializing...
7 BL-1020 BL-1020 Message , [BL-1020], , FFDC, CRITICAL, , Switch timed out initializing the chips. Probable Cause Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Restart or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is required.
BL-1023 Severity 7 CRITICAL BL-1023 Message , [BL-1023], ,, CRITICAL, , Blade in slot was reset before blade init completed. As a result the blade is faulted. Probable Cause Indicates that the blade was reset before the initialization completed. Recommended Action Restart or power cycle the blade. Severity If the message persists, replace the blade.
7 BL-1027 Probable Cause Indicates that an internal port went offline during the warm recovery of the switch. The switch will reboot and start a cold recovery. Recommended Action Collect supportSave information, then restart the switch and run the diagPost command to ensure Power-On Self-Test (POST) is enabled. If the problem persists, replace the switch.
BL-1030 7 BL-1030 Message , [BL-1030], ,, INFO, , All GigE/FCIP Virtualization/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset.
7 BL-1034 Probable Cause Indicates that the system has timed out while waiting for disable messages from the user ports after disabling the ports. Recommended Action Restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the message persists, replace the blade.
BL-1037 7 BL-1037 Message , [BL-1037], ,, CRITICAL, , Faulting chip in slot = , miniS = , port = due to BE/BI port fault. Probable Cause Indicates a fault on the chip and that all ports on the chip have been disabled. Recommended Action No action is required.
7 BL-1045 BL-1045 Message , [BL-1045], ,, ERROR, , mini SFP+ (SN: ) is only supported in certain high port count blades, not blade in slot w/ ID . Probable Cause Indicates that the mini (form factor) SFP+ is supported only by a certain type of blade (FC8-64), but it can be inserted in other blades.
BL-1049 Recommended Action Severity 7 Try turning off the interop mode using the interopmode command. Then execute the slotPowerOff and slotPowerOn commands on the FCoE blade. WARNING BL-1049 Message , [BL-1049], ,, INFO, , Serdestunemode is turned . Probable Cause Indicates that the serdestunemode is changed for the slot. Recommended Action No action is required.
7 76 BL-1049 Fabric OS Message Reference 53-1002149-01
Chapter BLL System Messages 8 BLL-1000 Message Probable Cause , [BLL-1000], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Indicates a blade regulation problem was reported on the specified slot number. The blade is faulted.
8 BLL-1000 Recommended Action Severity 78 Make sure the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have any hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace the blade.
Chapter BLS System Messages 9 BLS-1000 Message , [BLS-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid=. Probable Cause Indicates that the hardware is not responding to a command request, possibly because it is busy. Recommended Action Retry the command.
9 BLS-1003 BLS-1003 Message , [BLS-1003], , CFG, INFO, , An IPsec/IKE policy was deleted. Probable Cause Indicates that an IPsec or IKE policy was deleted and the configuration file was updated. Recommended Action No action is required.
Chapter BM System Messages 10 BM-1001 Message Probable Cause , [BM-1001], ,, ERROR, , BM protocol version in slot . Indicates that the firmware running on the control processor (CP) cannot communicate with the application processor (AP) blade in the indicated slot and determine the AP blade's firmware version. • • Recommended Action Severity The CP blade is running a later version of firmware than the AP blade.
10 BM-1004 Recommended Action Severity Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. WARNING BM-1004 Message Probable Cause Recommended Action Severity , [BM-1004], ,, INFO, , Blade firmware on slot is not consistent with system firmware . Auto-leveling blade firmware to match system firmware.
BM-1007 10 BM-1007 Message , [BM-1007], ,, INFO, , If set, clear EX/VEX/FC Fastwrite configuration for all ports for blade in slot . Probable Cause Indicates the specified blade was detected for the first time after an FR4-18i was previously configured in the same slot. The new blade requires the specified port configurations to be cleared. Recommended Action No action is required. The blade ports are cleared automatically.
10 BM-1053 Severity INFO BM-1053 Message , [BM-1053], , FFDC, WARNING, , Failed to establish connection between CP and Application Processor. Faulting switch. Probable Cause Indicates the control processor (CP) could not establish a connection with the application processor to communicate. Recommended Action On the Brocade 7500 or 7600, switch off and switch on all the primary power to power-cycle the unit.
BM-1058 Probable Cause 10 Indicates the policy of the specified switch is to persistently disable all ports the first time the AP is detected. This may be caused by one of the following: • The AP was detected for the first time on this switch. • The switch was configured under a different mode. Recommended Action Severity Configure the switch to persistently enable all ports.
10 86 BM-1058 Fabric OS Message Reference 53-1002149-01
Chapter C2 System Messages 11 C2-1001 Message , [C2-1001], ,, ERROR, , Port port faulted due to SFP validation failure. Please check if the SFP is valid for the configuration. Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Action Verify that you are using compatible SFPs on the peer ports.
11 C2-1006 C2-1006 Message Probable Cause Message , [C2-1006], ,, WARNING, , S,C: Internal link errors reported, no hardware faults identified, continuing monitoring: fault1:, fault2: thresh1:0x. Indicates a warning that some internal link errors have been detected. These can be normal in an active running system.
C2-1009 11 C2-1009 Message Message , [C2-1009], ,, WARNING, , S,P(): portcfglongdistance vc_translation_link_init = 1 overwrites fill word IDLE. ARB will be used on the link. Probable Cause Indicates portcfglongdistance vc_translation_link_init 1 overwrites fill word IDLE. ARB will be used on the link. Recommended Action No action is required.
11 C2-1014 Probable Cause Indicates that the selected table is corrupted. Recommended Action This message must have a matching message for the other duplicate. Reset both the specified ports. If it is a trunk, reset the entire trunk. Severity WARNING C2-1014 Message Message , [C2-1014], ,, WARNING, , Link Reset on Internal Port S,P() vc_no= crd(s)lost=.
C2-1017 11 C2-1017 Message Message , [C2-1017], ,, ERROR, , Blade in Slot failed due to unavailability of ports in the internal trunk. Probable Cause Indicates that the blade failed due to unavailability of the ports in the internal trunk. Recommended Action Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, replace the blade.
11 92 C2-1019 Fabric OS Message Reference 53-1002149-01
Chapter C3 System Messages 12 C3-1001 Message , [C3-1001], ,, ERROR, , Port failed due to SFP validation failure. Check if the SFP is valid for the configuration. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between the peer ports.
12 C3-1006 C3-1006 Message , [C3-1006], ,, WARNING, , S,C: Various non critical hardware errors were observed: fault1:0x, fault2:0x thresh1:0x. Probable Cause Indicates some errors found in hardware that may or may not impact data traffic. Recommended Action No action is required.
C3-1010 Recommended Action Severity 12 No action is required. WARNING C3-1010 Message , [C3-1010], ,, CRITICAL, , S,C: Above normal hardware errors were observed: fault1:, fault2: thresh2:0x. Probable Cause Indicates above normal errors observed in hardware that may or may not impact data traffic. Recommended Action Whenever this error is observed persistently, power cycle the faulted blade.
12 C3-1013 C3-1013 Message , [C3-1013], ,, INFO, , Maximum wait cycles to recover the lost frame or credit is exceeded on the internal Port Slot ,P() m_rdy(0x)/m_frame(0x). Probable Cause Indicates that wait cycles to recover the lost frame or credit is exceeded on the specified port.
C3-1017 Severity 12 ERROR C3-1017 Message , [C3-1017], ,, ERROR, , Blade in Slot failed due to unavailability of ports in the internal trunk. Probable Cause Indicates that the blade failed due to unavailability of the ports in the internal trunk. Recommended Action Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, replace the blade.
12 C3-1021 Severity WARNING C3-1021 Message , [C3-1021], ,, WARNING, , S,P(): Port offline due to Encryption Compression Block error. Probable Cause Indicates that an internal error is observed in the ASIC hardware that may degrade the data traffic. Recommended Action Whenever this error occurs, software recovers from the error. If the problem persists, replace the blade.
Chapter CAL System Messages 13 CAL-1001 Message , [CAL-1001], ,, INFO, , Switch offline requested by remote domain . Probable Cause Indicates a remote domain has requested the local domain to be disabled. Recommended Action See remote domain raslogs for the reason.
13 100 CAL-1001 Fabric OS Message Reference 53-1002149-01
Chapter CDR System Messages 14 CDR-1001 Message , [CDR-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable between peer ports, or that the port speed configuration does not match the capability of the SFP. Recommended Action Ensure that you are using compatible SFPs on the peer ports.
14 CDR-1004 CDR-1004 Message , [CDR-1004], , ERROR, , S, C: Invalid DMA ch pointer, chan:, good_addr:0x, bad_addr:0x. Probable Cause Indicates an internal error in the Application Specific Integrated Circuit (ASIC) hardware that may degrade data traffic. Recommended Action Whenever this error occurs, restart the system at the next maintenance window. If the problem persists, replace the blade.
CDR-1008 Recommended Action Severity 14 No action is required. WARNING CDR-1008 Message , [CDR-1008], ,, WARNING, , S,C: HW ASIC Chip warning Level 1 type = 0x. Probable Cause Indicates an internal error in the ASIC hardware that may or may not degrade data traffic. Recommended Action Whenever this error occurs, restart the system at the next maintenance window.
14 CDR-1012 Probable Cause Indicates that above normal errors were observed in hardware that may or may not impact the data traffic. Recommended Action Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, replace the blade.
CDR-1016 14 CDR-1016 Message , [CDR-1016], ,, ERROR, , Port is faulted due to port re-initialization failure on internal Port S,P() with reason . Probable Cause Indicates that port is faulted due to port re-initialization failure. Recommended Action Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, replace the blade.
14 106 CDR-1019 Fabric OS Message Reference 53-1002149-01
Chapter CEE CONFIG System Messages 15 CCFG-1001 Message , [CCFG-1001], ,, ERROR, , Failed to initialize , rc = . Probable Cause Indicates that initialization of a module within the Converged Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command.
15 CCFG-1005 Probable Cause Indicates that the startup configuration has been moved or deleted, hence replaying the system configuration has failed. Recommended Action Use the copy file startup-config command to restore the startup configuration from any backup retrieved on the server. Severity ERROR CCFG-1005 Message , [CCFG-1005], ,, INFO, , Startup configuration is updated.
CCFG-1009 Probable Cause Indicates that the CMSH initialization has failed. Recommended Action No action is required. Severity 15 ERROR CCFG-1009 Message , [CCFG-1009], ,, INFO, , Successfully copied to . Probable Cause Indicates that the file has been successfully copied to the destination. Recommended Action No action is required.
15 CCFG-1012 Probable Cause Indicates that the mentioned slot has failed to reach the Online state within the specified time after system ready event. Recommended Action Run the slotpoweroff command followed by the slotpoweron command on the slot to retry bringing the slot online.
Chapter CER System Messages 16 CER-1001 Message , [CER-1001], ,, ERROR, , HA Sync broken, since standby Advanced Performance Tuning module does not support FICON Management Server (FMS). Probable Cause Indicates that the high-availability (HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP.
16 112 CER-1001 Fabric OS Message Reference 53-1002149-01
Chapter CHASSIS System Messages 17 CHS-1002 Message , [CHS-1002], , FFDC, ERROR, , ki_gd_register_action failed with rc =. Probable Cause Indicates an internal error. Recommended Action For a bladed system, execute the slotPowerOff command and slotPowerOn commands on the blade to recover the system. For a non-bladed system, execute the fastBoot command on the switch to recover the system.
17 CHS-1005 CHS-1005 Message , [CHS-1005], ,, ERROR, , Diag attach failed during recovery, disabling slot = . Probable Cause Indicates that the Diag blade attach has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command.
Chapter CNM System Messages 18 CNM-1001 Message , [CNM-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR CNM-1002 Message , [CNM-1002], ,, ERROR, , Failed to initialize rc = .
18 CNM-1004 CNM-1004 Message , [CNM-1004], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended Action No action is required. Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [], WWN [].
CNM-1008 18 CNM-1008 Message , [CNM-1008], ,, INFO, , Posting event CNM_EVT_NODE_EJECT nodeName [], wwn []. Probable Cause Indicates that the node is ejected from the Encryption Group (EG). Recommended Action No action is required. Severity INFO CNM-1009 Message , [CNM-1009], ,, INFO, , Posting event CNM_EVT_STANDALONE_MODE. Probable Cause Indicates that the node is in standalone mode.
18 CNM-1012 CNM-1012 Message , [CNM-1012], ,, INFO, , Posting event CNM_EVT_EG_DELETED. Probable Cause Indicates that the Encryption Group (EG) is deleted. Recommended Action No action is required. Severity INFO CNM-1013 Message , [CNM-1013], ,, INFO, , Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the Encryption Group (EG) is split.
CNM-1016 18 CNM-1016 Message , [CNM-1016], ,, INFO, ,Posting event Detected a EG degrade condition. Probable Cause Indicates an Encryption Group (EG) degrade condition. Recommended Action No action is required. Severity INFO CNM-1017 Message , [CNM-1017], ,, INFO, , Got JOIN REQUEST from un-recognized GL node [], configured GL node is [].
18 CNM-1020 CNM-1020 Message , [CNM-1020], ,, INFO, , Node Admission Control failed, due to mismatch in certificates, rejecting node []. Probable Cause Indicates that the Node Admission Control has failed. Recommended Action No action is required. Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might fail.
CNM-1024 18 CNM-1024 Message , [CNM-1024], ,, INFO, , Operation not required on GL node. Probable Cause Indicates an operation is not required on a group leader (GL) node. Recommended Action No action is required. Severity INFO CNM-1025 Message , [CNM-1025], ,, INFO, , Operation not allowed, as member is active with the Cluster. Eject member node and retry.
18 CNM-1028 CNM-1028 Message , [CNM-1028], ,, INFO, , Certfile already exists. No need to sync up. Probable Cause Indicates that the certificate file for the node already exists. Recommended Action No action is required. Severity INFO CNM-1029 Message , [CNM-1029], ,, WARNING, , Certfile content does not match the cert sent by GL.
CNM-1032 18 CNM-1032 Message , [CNM-1032], ,, WARNING, , Certfile size does not match cert file size sent by GL Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended Action No action is required.
18 CNM-1036 CNM-1036 Message , [CNM-1036], ,, INFO, , All the active nodes of the cluster are in ONLINE state. Posting converged event. Probable Cause Indicates an event is being posted to indicate that the cluster is in a converged state. Recommended Action No action is required.
CNM-1040 18 CNM-1040 Message , [CNM-1040], ,, INFO, , Split-Brain Arbitration won, Majority WWN/GL Node, remote_wwn:local_wwn . Probable Cause Indicates that split arbitration is won. Recommended Action No action is required. Severity INFO CNM-1041 Message , [CNM-1041], ,, INFO, , Updating persistent Cluster DB, please avoid powering off the switch.
18 CNM-1044 CNM-1044 Message , [CNM-1044], ,, ERROR, , Cluster Create Failed as the Certificate files not found, Please do the initnode. Probable Cause Indicates that the initnode is not invoked. Recommended Action No action is required. Severity ERROR CNM-1045 Message , [CNM-1045], ,, ERROR, , Member node [] is having dual IP stack.Registering member node with dual IP in an EG with only IPV6 is not allowed.
CNM-1048 18 CNM-1048 Message , [CNM-1048], ,, INFO, , Posting . Probable Cause Indicates the event that is posted. Recommended Action No action is required. Severity INFO CNM-1049 Message , [CNM-1049], ,, ERROR, , Failed to define node, Node Name []. Probable Cause Indicates the system failed to define the node object. Recommended Action No action is required.
18 CNM-1052 CNM-1052 Message , [CNM-1052], ,, ERROR, , Member node registered with another Encryption Group. To proceed eject the member node from other EG. Probable Cause Indicates that the member node is registered with another Encryption Group (EG). Recommended Action No action is required. Severity ERROR CNM-1053 Message , [CNM-1053], ,, ERROR, , Node is already a registered member of another EG.
CNM-1056 18 CNM-1056 Message , [CNM-1056], ,, INFO, , Posting event CNM_EVT_EE_INITIALIZING Slot [], Wwn [], IP [], flags []. Probable Cause Indicates that the Encryption Engine (EE) is added into the Encryption Group (EG). Recommended Action No action is required.
18 CNM-1060 CNM-1060 Message , [CNM-1060], ,, INFO, , Local Node CP certificate pair mismatch detected. Probable Cause Indicates that the certificate pair is matched. Recommended Action No action is required. Severity INFO CNM-1061 Message , [CNM-1061], ,, INFO, , IP of the switch changed from [] to []. Probable Cause Indicates that the switch IP has changed.
CNM-3002 18 CNM-3002 Message , [CNM-3002], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: encryption group deleted. Probable Cause Indicates an encryption group was deleted. Recommended Action No action is required. Severity INFO CNM-3003 Message , [CNM-3003],,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Membernode \\ added to encryption group.
18 CNM-3006 CNM-3006 Message , [CNM-3006], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Heartbeat miss count set to . Probable Cause Indicates that the heartbeat miss value was set. Recommended Action No action is required. Severity INFO CNM-3007 Message , [CNM-3007],,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Heartbeat timeout set to .
CNM-3010 18 CNM-3010 Message , [CNM-3010],,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Membernode unregistered. Probable Cause Indicates a membernode was unregistered. Recommended Action No action is required. Severity INFO CNM-3011 Message , [CNM-3011], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Encryption group synchronized.
18 134 CNM-3012 Fabric OS Message Reference 53-1002149-01
Chapter CONF System Messages 19 CONF-1000 Message , [CONF-1000], , , INFO, CFG, , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed successfully. The statement that follows, message strings, is the description of the classes of configuration parameters that were downloaded.
19 CONF-1021 CONF-1021 Message , [CONF-1021], ,, INFO, , configUpload not permitted . Probable Cause Indicates a configUpload operation is not permitted. There are many possible causes. Recommended Action Check the error log, correct the error and rerun the configupload command.
CONF-1030 19 CONF-1030 Message , [CONF-1030], ,, WARNING, CFG, , Configuration database full, data not committed (key:. Probable Cause Indicates that the previous configuration commands have resulted in a database full condition. Configuration changes associated with the specified key have not been applied.
19 CONF-1041 CONF-1041 Message , [CONF-1041], ,, INFO, CFG, , configRemove failed. Probable Cause Indicates a configRemove error has occurred. Recommended Action Correct the error and try again. Severity INFO CONF-1042 Message , [CONF-1042], ,, INFO, CFG, , Fabric Configuration Parameter changed to . Probable Cause Indicates that the parameter value has been changed.
Chapter CTAP System Messages 20 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each pool. Recommended Action Do not start tape backup or restore operations involving tape pools until the process is complete.
20 140 CTAP-1001 Fabric OS Message Reference 53-1002149-01
Chapter CVLC System Messages 21 CVLC-1001 Message , [CVLC-1001], ,, INFO, , re-key , LUN SN: . Container: , Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed.
21 CVLC-1004 CVLC-1004 Message , [CVLC-1004], ,, INFO, , Forceful encryption LUN removal while re-key session is still active. Container: , Initiator: , LUN ID: . Probable Cause Indicates that the encryption LUN was forcefully removed while a re-key session was still active. Recommended Action No action is required.
CVLC-1008 Recommended Action 21 If you want to preserve the user data, use cryptocfg --modLUNpolicy -cleartext to convert to clear text LUN. Use cryptocfg ---modLUNpolicy -disable_allowdecrypt to disable decryption of existing data. Then try the LUN deletion again. Severity ERROR CVLC-1008 Message , [CVLC-1008], ,, ERROR, , LUN discovery failure: , Container: , Initiator: , LUN ID: .
21 CVLC-1011 CVLC-1011 Message , [CVLC-1011], ,, ERROR, , Third party license is required for encryption LUN in third party mode. Container: , Initiator: , LUN ID: . Probable Cause Indicates that the encryption LUN is configured with non-Brocade mode but there is no valid license. Recommended Action Obtain license for non-Brocade mode.
CVLC-1015 21 Probable Cause Indicates that the data state in the LUN configuration is in the encrypted state without a key ID and there is no metadata found on the LUN. Recommended Action Use cryptocfg command to add the key ID, if available. Severity ERROR CVLC-1015 Message , [CVLC-1015], ,, INFO, , LUN is set to read only mode. Reason: .
21 CVLC-1018 CVLC-1018 Message , [CVLC-1018], ,, INFO, , Event: . Container: , Initiator: , LUN ID: . Probable Cause Indicates an informational event. Recommended Action No action is required. Severity INFO CVLC-1019 Message , [CVLC-1019], ,, ERROR, , Metadata exists while data state is clear text.
CVLC-1022 Probable Cause Indicates that the key ID provided is ignored because metadata exists on the LUN. Recommended Action No action is required. Severity 21 INFO CVLC-1022 Message , [CVLC-1022], ,, INFO, , User provided key ID is ignored while data state is clear text. Container: , Initiator: , LUN ID: .
21 CVLC-1025 CVLC-1025 Message , [CVLC-1025], ,, ERROR, , Secondary Metadata exists for encrypted LUN not configured with -newLUN option . Container: , Initiator: , LUN ID: . Probable Cause Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN option. Recommended Action Use th ecryptocfg command to remove and add the LUN with --newLUN option.
CVLC-1029 Probable Cause Indicates a warning event. Recommended Action Perform a manual rekey on this LUN. Severity 21 WARNING CVLC-1029 Message , [CVLC-1029], ,, WARNING, , Mirror LUN is disabled as primary LUN is being rekeyed without splitting the mirror. Container: , Initiator: , LUN ID: . Probable Cause Indicates performing FTE or manual rekey of primary LUN without splitting the mirror.
21 CVLC-1032 3. Using host based migration application, copy data from old to new primary LUN. Severity WARNING CVLC-1032 Message , [CVLC-1032], ,, INFO, , Secondary metadata for LUN has been restored. Container: , Initiator: , LUN ID: . Probable Cause Indicates the host I/Os to secondary metadata region. Recommended Action No action is required.
CVLC-1041 Probable Cause Indicates that decommissioned LUN has been added back as encrypted LUN. Recommended Action 1. Remove LUN from container. 21 2. Add it back as a cleartext LUN. 3. Modify LUN policy to encrypt. Severity ERROR CVLC-1041 Message , [CVLC-1041], ,, WARNING, , . Container: , Initiator: , LUN ID: .
21 152 CVLC-1041 Fabric OS Message Reference 53-1002149-01
Chapter CVLM System Messages 22 CVLM-1001 Message , [CVLM-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Restart or power cycle the switch.
22 CVLM-1005 Probable Cause Indicates that EE nodes in the cluster encryption group have different configurations. Recommended Action Synchronize the configuration in the cluster group using the cryptocfg --commit command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch.
CVLM-1009 Recommended Action Severity 22 Check the ISL port connected to the fabric. WARNING CVLM-1009 Message , [CVLM-1009], ,, INFO, , The member () of HAC () is in the fabric. Probable Cause Indicates that the member of HAC is found in the fabric. Recommended Action No action is required.
22 CVLM-3001 Recommended Action Severity No action is required. INFO CVLM-3001 Message , [CVLM-3001], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates the failback mode was set. Recommended Action No action is required.
CVLM-3005 Recommended Action Severity 22 No action is required. INFO CVLM-3005 Message , [CVLM-3005], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Cluster member removed from HA cluster . Probable Cause Indicates an HA cluster member was removed from an HA cluster. Recommended Action No action is required.
22 CVLM-3009 Recommended Action Severity No action is required. INFO CVLM-3009 Message , [CVLM-3009], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended Action No action is required.
CVLM-3013 Probable Cause Indicates an initiator was removed from a cryptotarget container. Recommended Action No action is required. Severity 22 INFO CVLM-3013 Message , [CVLM-3013], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: LUN , attached through Initiator \\, added to crypto target container \\. Probable Cause Indicates a LUN was added to a cryptotarget container.
22 CVLM-3016 CVLM-3016 Message , [CVLM-3016], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Lun , attached through Initiator \\, in crypto target container \\ enabled. Probable Cause Indicates a LUN in a cryptotarget container was enabled. Recommended Action No action is required.
CVLM-3020 22 CVLM-3020 Message , [CVLM-3020], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Manual rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable Cause Indicates a manual rekey of a LUN was performed. Recommended Action No action is required.
22 CVLM-3024 Severity INFO CVLM-3024 Message , [CVLM-3024], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Transaction aborted. Probable Cause Indicates a transaction abort operation was performed. Recommended Action No action is required.
CVLM-3028 Severity 22 INFO CVLM-3028 Message , [CVLM-3028], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: SRDF mode set to . Probable Cause Indicates that the SRDF mode was set. Recommended Action No action is required.
22 164 CVLM-3028 Fabric OS Message Reference 53-1002149-01
Chapter DAUTH System Messages 23 DOT1-1001 Message , [DOT1-1001], ,, INFO, 802.1X is enabled globally. Probable Cause Indicates that the 802.1X is enabled globally. Recommended Action No action is required. Severity INFO DOT1-1002 Message , [DOT1-1002], ,, INFO, 802.1X is disabled globally. Probable Cause Indicates that the 802.1X is disabled globally. Recommended Action No action is required.
23 DOT1-1005 Recommended Action Severity No action is required. INFO DOT1-1005 Message , [DOT1-1005], ,, INFO, 802.1X Authentication is successful on port . Probable Cause Indicates that the authentication has succeeded on a particular port. Recommended Action No action is required. Severity INFO DOT1-1006 Message , [DOT1-1006], ,, WARNING, 802.1X Authentication has failed on port .
DOT1-1009 Recommended Action Severity 23 No action is required. INFO DOT1-1009 Message , [DOT1-1009], ,, INFO, 802.1X is disabled for port . Probable Cause Indicates that the 802.1X is disabled for a particular port. Recommended Action No action is required. Severity INFO DOT1-1010 Message , [DOT1-1010], ,, INFO, Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode.
23 168 DOT1-1010 Fabric OS Message Reference 53-1002149-01
Chapter ECC System Messages 24 ECC-1000 Message , [ECC-1000], ,, ERROR, , ECC Error occurrence of . Probable Cause Indicates that the processor memory controller has detected one of several types of DDR memory errors.
24 170 ECC-1001 Fabric OS Message Reference 53-1001338-01
Chapter EM System Messages 25 EM-1001 Message , [EM-1001], , FFDC, CRITICAL, , is over heating: Shutting down. Probable Cause Indicates that a field-replaceable unit (FRU) is shutting down due to overheating. This is typically due to a faulty fan but can also be caused by the switch environment. Recommended Action Verify that the location temperature is within the operational range of the switch.
25 EM-1004 Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more information on this command. On the Brocade 24000 and 48000, replace the specified FRU. For the Brocade 3900, replace the motherboard FRU. For the Brocade 200E, 300, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 6510, 7500, and AP7600, replace the switch.
EM-1006 25 EM-1006 Message , [EM-1006], , FFDC, CRITICAL, , has faulted. Sensors below minimum limits. Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade is being shut down for environmental reasons; the voltage is too low. Recommended Action If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the blade.
25 EM-1009 EM-1009 Message , [EM-1009], , FFDC, CRITICAL, , powered down unexpectedly. Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the specified field-replaceable unit (FRU). This might indicate a hardware malfunction in the FRU. Recommended Action Try reseating the FRU. If the message persists, replace the FRU.
EM-1013 25 Probable Cause Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is faulted. The specific failed target state is displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action Try reseating the indicated field-replaceable unit (FRU). If the message persists, restart or power cycle the switch.
25 EM-1016 Severity WARNING EM-1016 Message , [EM-1016], ,, WARNING, , Cold recovery failed (). Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
EM-1020 25 Probable Cause Indicates that the current chassisConfig option is not supported by the firmware on the standby control processor (CP). This is true even if the standby comes up and appears to be operational. High availability (HA) synchronization of the CPs will not be allowed. Recommended Action Either change the chassis config option to 1 with the chassisConfig command, or upgrade the firmware on the standby to the version running on the active CP.
25 EM-1031 Probable Cause Indicates that the I2C bus had problems and a timeout occurred. Recommended Action This is often a transient error. Watch for the EM-1048 message, which indicates that the problem has been resolved. If the error persists, check for loose or dirty connections. Remove all dust and debris prior to reseating the field-replaceable unit (FRU). If it continues to fail, replace the FRU.
EM-1035 25 Probable Cause Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified reason. Recommended Action Try reseating the FRU. Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace the FRU.
25 EM-1037 EM-1037 Message , [EM-1037], ,, INFO, , is no longer faulted. Probable Cause Indicates that the specified power supply has been marked as no longer being faulty, probably because its AC power supply has been turned on. Recommended Action No action is required. Severity INFO EM-1042 Message , [EM-1042], ,, WARNING, , Important FRU header data for is not valid).
EM-1045 Severity 25 WARNING EM-1045 Message , [EM-1045], ,, WARNING, , is being powered . Probable Cause Indicates that an automatic power adjustment is being made because of the (predicted) failure of a power supply or the insertion or removal of a port blade. If new_state is On, a port blade is being powered on because more power is available (either a power supply was inserted or a port blade was removed or powered down).
25 EM-1048 EM-1048 Message , [EM-1048], ,, INFO, , I2C access recovered: state Probable Cause Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available again. Recommended Action The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is displayed.
EM-1057 Severity 25 INFO EM-1057 Message , [EM-1057], ,, WARNING, , Blade: is getting reset:. Probable Cause Indicates the blade is being automatically reset because of known resetable transient errors such as an application-specific integrated circuit (ASIC) parity error. Recommended Action No action is required if the switch does not reach the reset threshold for the switch or blade.
25 EM-1060 EM-1060 Message , [EM-1060], ,, WARNING, , Stopping synchronization of the system due to blade incompatibility with software version on standby CP. Probable Cause Indicates a blade in the system is not supported by the release on the standby control processor (CP). Recommended Action Remove all blades of this type or upgrade your standby CP.
EM-1064 Recommended Action Severity 25 Remove the faulted blade. CRITICAL EM-1064 Message , [EM-1064], ,, CRITICAL, , Blade: is being powered off (based on user configuration) upon receiving a HW ASIC ERROR, reason:.
25 EM-1067 EM-1067 Message , [EM-1067], ,, WARNING, , Stopping synchronization of the system due to incompatibility with standby CP. Probable Cause Indicates that the software version on the standby CP is not compatible with this software eature enabled on this Fabric OS firmware version. Recommended Action Upgrade the software on the standby CP or disable the software feature on this CP. To disable the ethsw service, run fosconfig --disable ethsw.
EM-1070 25 EM-1070 Message , [EM-1070], ,, INFO, , Slot is being powered on. Probable Cause Indicates a blade is being intentionally powered on. Recommended Action No action is required. Severity INFO EM-1071 Message , [EM-1071], , FFDC, CRITICAL, , Unit in with ID is faulted, it is incompatible with the following blade id(s): .
25 188 EM-2003 Fabric OS Message Reference 53-1002149-01
Chapter ESS System Messages 26 ESS-1001 Message , [ESS-1001], ,, WARNING, , A few switches in the fabric do not support the Coordinated HotCode protocol. Probable Cause Indicates one or more switches in the fabric do not support the Coordinated HotCode protocol. Continuing with the firmware download may cause data traffic disruption.
26 ESS-1004 ESS-1004 Message , [ESS-1004], ,, WARNING, , The resume message is rejected by the domain . Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message. Recommended Action No action is required.
ESS-1010 Severity 26 WARNING ESS-1010 Message , [ESS-1010], ,, WARNING, FABRIC, , Duplicate Fabric Name - matching with FID . Probable Cause Indicates that the configured fabric name is already used for another partition. Recommended Action Select a different fabric name and reconfigure.
26 192 ESS-1010 Fabric OS Message Reference 53-1002149-01
Chapter ESWCH System Messages 27 ESW-1001 Message , [ESW-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates that the switch enable has failed. Recommended Action If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
27 ESW-1004 ESW-1004 Message , [ESW-1004], ,, ERROR, ,Blade attach failed during recovery, disabling slot = . Probable Cause Indicates that the blade has failed during failover or recovery. Recommended Action On a Brocade 8000 switch, restart or power cycle the switch. Severity ERROR ESW-1005 Message , [ESW-1005], ,, ERROR, ,Diag attach failed during recovery, disabling slot = .
ESW-1008 Severity 27 WARNING ESW-1008 Message , [ESW-1008], ,, WARNING, , are port swapped on ports that do not support port swap. Slot will be faulted. Probable Cause Indicates that the blade has area swapped ports on ports that do not support this feature. Recommended Action Replace the blade with ports that support port swap. Refer to the Fabric OS Administrator’s Guide for more information.
27 196 ESW-1008 Fabric OS Message Reference 53-1002149-01
Chapter EVMD System Messages 28 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = . Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy switch cannot be reached through in-band. The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band.
28 198 EVMD-1001 Fabric OS Message Reference 53-1002149-01
Chapter FABR System Messages 29 FABR-1001 Message , [FABR-1001], ,, WARNING, , port , . Probable Cause Indicates that the specified switch port is isolated because of a segmentation resulting from mismatched configuration parameters. Recommended Action Based on the segmentation reason displayed within the message, look for a possible mismatch of relevant configuration parameters in the switches at both ends of the link.
29 FABR-1004 Run the fabStateShow command on both the receiving and transmitting switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
FABR-1007 Recommended Action 29 In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], ,, WARNING, , IU free error, caller: .
29 FABR-1010 Recommended Action Severity The fabric daemon will discard the EFP. The system will recover through the EFP retrial process. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1010 Message , [FABR-1010], ,, WARNING, , .
FABR-1013 29 FABR-1013 Message , [FABR-1013], , FFDC, CRITICAL, , No Memory: pid= file= line=. Probable Cause Indicates that there is not enough memory in the switch for the fabric module to allocate. This message is rare and usually indicates a problem with the Fabric OS. Recommended Action The system will recover by failing over to the standby CP.
29 FABR-1016 FABR-1016 Message , [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended Action No action is required. Severity WARNING FABR-1017 Message , [FABR-1017], ,, WARNING, , ficonMode is disabled. Probable Cause Indicates that FICON mode is disabled on the switch through a user interface command.
FABR-1020 29 Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the number of domains. This limit is defined by your specific value-line license key. The fabric size has exceeded this specified limit, and the grace period counter has started. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled.
29 FABR-1023 Probable Cause Indicates that the fabric size has exceeded the value-line limit, and the grace period counter has started. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled. Recommended Action Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license.
FABR-1030 29 There are three types of flow control modes: • VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol. • R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control. • DUAL_CR mode: Dual-credit flow control mode. In both of the previous modes, the buffer credits are fixed, based on the port configuration information.
29 FABR-1034 Severity WARNING FABR-1034 Message , [FABR-1034], , INFO, , Area have been acquired by port . Persistently disabling port . Probable Cause Indicates you must enable Trunk Area on a port for another port to use the same area. Recommended Action Move the cable to a port area that is not in use, or disable Trunk Area.
FABR-1038 29 Probable Cause Indicates the specified port is being disabled because when the port attempts to go online, the Switch finds that Trunk Area enabled is incompatible with port configuration such as long distance, port mirror, fast write or EX_port. Recommended Action Check the port configuration to disable long distance, port mirror, fast write or EX_port.
29 FABR-1041 FABR-1041 Message , [FABR-1041], ,, ERROR, , Port is disabled due to trunk protocol error. Probable Cause Indicates a link reset was received before the completion of the trunking protocol on the port. Recommended Action Enable the port by running the portEnable command. The port may recover by re-initialization of the link.
FABR-1046 29 Probable Cause Indicates that the remote switch has a Base Switch attribute conflict with the local switch. But no ports are disabled because the remote switch is not adjacent to the local switch. Recommended Action Make sure that all the switches in the fabric have the same Base Switch attribute or disable VF mode for the conflicting switch using the fosconfig command.
29 FABR-1049 FABR-1049 Message , [FABR-1049], ,, ERROR, , Detected Fabric ID (FID inherited) conflict with neighbor switch (domain , FID ). E-ports () connected to the switch are disabled. Probable Cause Indicates that the neighbor switch has Fabric ID conflict with the inherited FID of the local switch. All E_ports directly connected to the conflicting switch are disabled.
FABR-1053 Probable Cause Indicates that the configured speed (16G/10G on non C3 blade or 1G on C3 blade) for the specified port is invalid. Recommended Action Execute the portcfgspeed command to change the port speed. Severity 29 INFO FABR-1053 Message , [FABR-1053], ,, CRITICAL, , The switch is disabled due to an inconsistency found in the interop config parameters. Probable Cause Indicates that the config keys have interopmode parameters such as switch.
29 214 FABR-1055 Fabric OS Message Reference 53-1002149-01
Chapter FABS System Messages 30 FABS-1001 Message , [FABS-1001], , FFDC, CRITICAL, , Probable Cause Indicates that the system is low on memory and cannot allocate more memory for new operations. This is usually an internal Fabric OS problem or file corruption. Description of memory need indicates how much memory was being requested. The value could be any whole number.
30 FABS-1005 FABS-1005 Message Probable Cause , [FABS-1005], ,, WARNING, , (= ) Indicates that an unsupported operation has been requested. This is usually an internal Fabric OS problem or file corruption. The possible value for function name and description of problem is: fabsys_write: Unsupported write operation: process xxx where xxx is the process ID (PID), which could be any whole number.
FABS-1008 Severity 30 WARNING FABS-1008 Message , [FABS-1008], ,, WARNING, , : Media oid mapping failed Probable Cause Indicates that the Fabric OS was unable to locate a necessary object handle. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch.
30 FABS-1012 Recommended Action Severity Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. ERROR FABS-1012 Message , [FABS-1012], ,, ERROR, , []:FRU state transition failed. Current state 0x Requested state 0x err 0x Probable Cause A FRU could not be transitioned to the requested state.
FABS-1015 Severity 30 ERROR FABS-1015 Message , [FABS-1015], ,, ERROR, , []:Request to enable FRU type 0x, unit failed. err code Probable Cause Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system.
30 220 FABS-1015 Fabric OS Message Reference 53-1002149-01
Chapter FBC System Messages 31 FBC-1001 Message , [FBC-1001], ,, ERROR, , Firmware version on AP blade is incompatible with that on the CP. Probable Cause The CP determined that the version of firmware running on the AP blade is not compatible with the version of firmware running on the CP. The AP and CP blades cannot communicate. Recommended Action The problem can be corrected by changing the version of firmware on the CP or AP blades.
31 222 FBC-1001 Fabric OS Message Reference 53-1002149-01
Chapter FCIP System Messages 32 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= Probable Cause Indicates that the hardware is not responding to a command request, possibly because it is busy. Recommended Action Retry the command.
32 FCIP-1003 FCIP-1003 Message , [FCIP-1003], , INFO, CFG, , An IPsec/IKE policy was deleted. Probable Cause Indicates that an IPsec/IKE policy was deleted and the config file was updated. Recommended Action No action is required. Severity INFO FCIP-1004 Message , [FCIP-1004], ,, INFO, , Tape Read Pipelining is being disabled slot () port () tunnel ().
Chapter FCMC System Messages 33 FCMC-1001 Message , [FCMC-1001], , FFDC, CRITICAL, , System is low on memory and has failed to allocate new memory. Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for an information unit (IU). Recommended Action A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP.
33 226 FCMC-1001 Fabric OS Message Reference 53-1002149-01
Chapter FCOE System Messages 34 FCOE-1001 Message , [FCOE-1001], ,, ERROR, , calloc failed for
34 FCOE-1005 Recommended Action Severity Remove the failed member from the logingroup. ERROR FCOE-1005 Message , [FCOE-1005], ,, ERROR, , : membership check failed in logingroup: Probable Cause Indicates that the Membership check for the device has failed. Recommended Action Check the device for failed Membership.
FCOE-1010 Recommended Action Severity 34 Remove unwanted nport mappings and try adding nport mapping. INFO FCOE-1010 Message , [FCOE-1010], ,, ERROR, , Cleanup of login failed for port:. Probable Cause Indicates an invalid port number. Recommended Action Use the supportsave command and restart the system.
34 FCOE-1015 Recommended Action Severity Request to add ports to VLAN failed. ERROR FCOE-1015 Message , [FCOE-1015], ,, ERROR, , Request to add MACs to Layer 2 for ifindex 0xx failed, rc:. Probable Cause Indicates that an add request to Layer 2 for slot or port has failed. Recommended Action Request to add MACs to Layer 2 for slot or port failed.
FCOE-1019 Recommended Action Severity 34 Request to delete MACs from Layer 2 for slot or port failed. ERROR FCOE-1019 Message , [FCOE-1019], ,, WARNING, , FLOGI ignored as FC-MAP not configured on FCOE VLAN. Probable Cause Indicates that the FC-MAP has not been configured on FCOE VLAN. Recommended Action Configure FC-MAP on FCOE VLAN.
34 FCOE-1024 Recommended Action Severity No action is required. WARNING FCOE-1024 Message , [FCOE-1024], ,, WARNING, , FDISC received from Enode without prior FLOGI. Probable Cause Indicates that no root Nport has logged in. Recommended Action No action is required. Severity WARNING FCOE-1025 Message , [FCOE-1025], ,, WARNING, , FCOE logout received on FIP VN port.
FCOE-1028 Recommended Action Severity 34 No action is required. ERROR FCOE-1028 Message , [FCOE-1028], ,, ERROR, , : . Probable Cause Indicates the FCoE device with following WWN is not a member of the login group: WWN will be printed. Recommended Action Change the FCoE login group policy on the switch for the device to login.
34 FCOE-1032 Recommended Action Severity No action is required. WARNING FCOE-1032 Message , [FCOE-1032], ,, WARNING, , We are in WARM RECOVERING state. Probable Cause Indicates that a HA failover or reboot may be in progress. Recommended Action No action is required. Severity WARNING FCOE-1033 Message , [FCOE-1033], ,, WARNING, , FIP v1 FLOGI received - VF port in use.
FCOE-1038 Recommended Action Severity 34 Create a logingroup for the switch WWN with another name that will not lead to a name conflict. WARNING FCOE-1038 Message , [FCOE-1038], ,, INFO, , logingroup# ()created. Probable Cause Indicates that the logingroup is added in the switch logingroup table. Recommended Action No action is required.
34 FCOE-1042 Recommended Action Severity No action is required. INFO FCOE-1042 Message , [FCOE-1042], ,, INFO, , FCoE login configuration transaction saved fabric-wide. Probable Cause Indicates that the FCoE login configuration transaction is saved fabric-wide. Recommended Action No action is required. Severity INFO FCOE-1043 Message , [FCOE-1043], ,, INFO, , FCoE login configuration management disabled.
FCOE-1046 Recommended Action Severity 34 No action is required. INFO FCOE-1046 Message , [FCOE-1046], ,, INFO, , fcoed.conf file is truncated. Please reconfigure FCoE ports. Probable Cause Indicates the magic number in the fcoed.conf file does not match. The fcoed.conf file is truncated and updated with a new magic number. Recommended Action Reconfigure the FCoE ports as all the port configurations will be lost.
34 238 FCOE-1048 Fabric OS Message Reference 53-1002149-01
Chapter FCPD System Messages 35 FCPD-1001 Message Probable Cause , [FCPD-1001], ,, WARNING, , Probing failed on . Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing failed on the L_Port, AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF.
35 240 FCPD-1003 Fabric OS Message Reference 53-1002149-01
Chapter FCPH System Messages 36 FCPH-1001 Message Probable Cause , [FCPH-1001], , FFDC, CRITICAL, , : failed, out of memory condition Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed function call kmalloc_wrapper has failed.
36 FCPH-1004 Severity WARNING FCPH-1004 Message , [FCPH-1004], ,, WARNING, , NPIV port has same Port WWN with old port with pid 0x as part of duplicate Port WWN detection policy. Probable Cause Indicates that this port is older port of same port name of NPV device. Recommended Action No action is required.
Chapter FCR System Messages 37 FCR-1001 Message , [FCR-1001], ,, INFO, , FC router proxy device in edge created at port . Probable Cause Indicates that a proxy device at the port in the edge fabric has been imported at the specified port. Recommended Action No action is required. Severity INFO FCR-1002 Message , [FCR-1002], ,, INFO, , FC router proxy device in edge deleted at port .
37 FCR-1005 Recommended Action Severity Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary. INFO FCR-1005 Message , [FCR-1005], ,, INFO, , FC router LSAN zone device removed at port .
FCR-1008 37 FCR-1008 Message , [FCR-1008], ,, INFO, , FC router LSAN zone created at port . Probable Cause Indicates that a logical storage area network (LSAN) zone was created at the specified port in the edge fabric. Recommended Action No action is required. Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN zone enabled at port : .
37 FCR-1012 Severity INFO FCR-1012 Message , [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended Action No action is required. Severity INFO FCR-1013 Message , [FCR-1013], ,, INFO, , Phantom FSPF database exchange completed on port .
FCR-1018 Recommended Action Severity 37 No action is required. INFO FCR-1018 Message , [FCR-1018], ,, ERROR, , FC router proxy device entries exhausted on port . Probable Cause Indicates that the number of proxy devices is greater than allowed by the port resource. Recommended Action Remove excess logical storage area network (LSAN) zones or devices until the number of proxy devices exported is within the range allowed by the port resource.
37 FCR-1021 To do that, perform the following steps: 1. Run the portDisable command to disable all the EX_Ports that got this error message. 2. Run the portDisable command to disable all the other EX_Ports on that FCR connected to the same edge fabrics the EX_ports disabled in step 1 are connected to. 3. Use Zoning commands on the edge fabrics, to reduce the LSAN zone entries on the edge fabrics. 4. Run portEnable on each EX_Port, one at a time, and verify that this error is not reported again.
FCR-1024 Severity 37 WARNING FCR-1024 Message , [FCR-1024], ,, WARNING, , Local LSAN zone device entries for edge LSAN exhausted. Probable Cause Indicates that the number of devices in a logical storage area network (LSAN) defined in the edge fabric exceeds the local LSAN zone database limitations.
37 FCR-1027 FCR-1027 Message , [FCR-1027], ,, INFO, , In slot port WWN roll over. Probable Cause Indicates that the port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed.
FCR-1030 Severity 37 INFO FCR-1030 Message , [FCR-1030], ,, INFO, , Physical device came online at fabric . Probable Cause Indicates that the physical device world wide name (WWN) came online in the specified fabric. Recommended Action No action is required. Severity INFO FCR-1031 Message , [FCR-1031], ,, INFO, , Physical device went offline in fabric .
37 FCR-1034 FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric. Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone fabric. Recommended Action No action is required. Severity INFO FCR-1035 Message , [FCR-1035], ,, INFO, , LSAN zone device added in the backbone fabric.
FCR-1038 37 FCR-1038 Message , [FCR-1038], ,, WARNING, , Total zone entries exceeded local fabric limits by entries, in zone: , zone limit: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch&apos zone database limitations.
37 FCR-1042 Severity INFO FCR-1042 Message , [FCR-1042], ,, INFO, , LSAN zone removed in the backbone fabric. Probable Cause Indicates that a logical storage area network (LSAN) zone within the backbone fabric was removed. Recommended Action No action is required. Severity INFO FCR-1043 Message , [FCR-1043], ,, INFO, , Proxy device created in the backbone fabric.
FCR-1053 Recommended Action Severity 37 Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port was disabled, . Probable Cause Indicates that the specified port was disabled because of a mismatched configuration parameter.
37 FCR-1056 Severity INFO FCR-1056 Message , [FCR-1056], ,, INFO, , Switch with front domain ID does not support backbone to edge imports. Probable Cause Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN. Recommended Action No action is required if backbone-to-edge routing is not needed. Otherwise replace the switch with one that supports backbone to edge routing.
FCR-1059 37 FCR-1059 Message , [FCR-1059], ,, INFO, , EX_Port was disabled due to an authentication failure. Probable Cause Indicates that the authentication, which uses the Diffie Hellman - challenge handshake authentication Protocol (DH-CHAP), failed on the EX_Port. Recommended Action Verify that the shared secrets on both sides of the link match.
37 FCR-1062 FCR-1062 Message , [FCR-1062], ,, INFO, , Port disabled, system only supports EX/VEX_ports. Probable Cause Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Recommended Action No action is required.
FCR-1066 Recommended Action Severity 37 Change the port fabric ID to same value as the other ports connected to the edge fabric using the portCfgExport or portCfgVexport commands. ERROR FCR-1066 Message , [FCR-1066], ,, ERROR, , Fabric on port has the same fabric ID as another fabric.
37 FCR-1069 FCR-1069 Message , [FCR-1069], ,, INFO, , The FC Routing service is enabled. Probable Cause Indicates that the FC Routing service is enabled. This is caused by either fosConfig –-enable fcr, or a configDownload with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended Action No action is required.
FCR-1073 37 FCR-1073 Message , [FCR-1073], ,, INFO, , Switch with domain ID in fabric has lower limit of LSAN Zones supported. Probable Cause Indicates that an earlier version of the switch in the backbone or edge that supports a different limit of logical storage area network (LSAN) zones was detected.
37 FCR-1076 FCR-1076 Message , [FCR-1076], ,, INFO, , Port disabled, system only supports front domains. Probable Cause Indicates that the maximum number of supported front domains was exceeded. To enable the specified port, disable any other operational front domain and then re-enable the port. Recommended Action Make sure to remain within the maximum of supported front domains.
FCR-1080 Recommended Action Severity 37 Change the matrix database. WARNING FCR-1080 Message , [FCR-1080], ,, WARNING, , The pause response timer for domain expired. Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has not responded to the pause message which prevented the protocol from completing.
37 FCR-1083 FCR-1083 Message , [FCR-1083], ,, WARNING, , The resume message is rejected by the domain . Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message. Recommended Action No action is required.
FCR-1087 Recommended Action Severity 37 Disable Condor2-based EX_ports or upgrade the remote CP. ERROR FCR-1087 Message , [FCR-1087], ,, ERROR, , ExPort connects to fabric with capability to use XISL domain . Probable Cause Indicates that the EX_Port connects to logical fabric containing a domain has the capability to use XISL. Recommended Action Disable the ‘Allow to use XISL’ mode of the domain by using the configure command.
37 FCR-1092 Recommended Action Severity No action is required. INFO FCR-1092 Message , [FCR-1092], ,, ERROR, , FCR ELS trap entries exhausted. Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Action Collect supportsave data and send it to support.
Chapter FICON System Messages 38 The FICON messages in this chapter include in many of the messages. The FICON Path is a string that includes, VEHDHPDDDPLPCUDV where: VE - VE Port Number: This number represents the FCIP Tunnel number through its VE Port number. HD - Host switch Domain number: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to.
38 FICN-1004 Severity WARNING FICN-1004 Message , [FICN-1004], ,, WARNING, , FICON XRC Emulation License Key is not installed. Probable Cause Indicates FICON XRC Emulation requires a License Key. Recommended Action Use the appropriate License Key.
FICN-1007 38 FICN-1007 Message , [FICN-1007], ,, ERROR, , DevDiskEgr:FICON Selective Reset:Path= State=0x stat_array=0x. Probable Cause Indicates a Selective Reset from the channel was received as either a normal part of path recovery or starting sequence in an error case.
38 FICN-1011 Probable Cause Indicates a Device Level Exception frame was received from the FICON Channel. Recommended Action If there was a job or IO failure associated with this event, contact your vendor's customer support for assistance.
FICN-1014 Severity 38 INFO FICN-1014 Message , [FICN-1014], ,, INFO, , DevEgr:Device level exception flag found for Path=0x : Oxid=0x. Probable Cause Indicates a frame was received that indicated device level exception.
38 FICN-1018 Probable Cause Indicates the FICON Control Unit sent an LPE frame to the FICON channel. Recommended Action This is an informational message and does not require any action. Severity INFO FICN-1018 Message , [FICN-1018], ,, ERROR, , DevIng:FCUB Lookup failed for Path=0x .
FICN-1021 38 FICN-1021 Message , [FICN-1021], ,, WARNING, , DevTapeEgr:FICON Tape Cancel:Path=0x Elapsed Time=. seconds. Probable Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation.
38 FICN-1024 FICN-1024 Message , [FICN-1024], ,, ERROR, , DevTapeEgr:FICON Purge received Path= . Probable Cause Indicates the FICON channel issued a Purge Path command sequence for a device. Recommended Action If there was an unexpected job failure or IO Error associated with this event, contact your vendor's customer support for assistance.
FICN-1028 Recommended Action Severity 38 If there was an unexpected job failure or IO Error associated with this event, contact your vendor's customer support for assistance. ERROR FICN-1028 Message , [FICN-1028], ,, WARNING, , HostDiskIng:FICON Cancel received Path= state=0x.
38 FICN-1031 FICN-1031 Message , [FICN-1031], ,, WARNING, , HostDiskIng:FICON System Reset received on Path=. Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit. Recommended Action No action is required. The MVS system was either set to IPL or performing error recovery.
FICN-1035 38 Probable Cause Indicates the channel emulation processing received a frame with an invalid FICON LRC from the peer. This indicates that the channel side noted corruption from the device/CU side processing. Recommended Action Contact your vendor's customer support for assistance.
38 FICN-1038 FICN-1038 Message , [FICN-1038], ,, ERROR, , fcFicIngHost:FDCB Lookup failed for Path=0x . Probable Cause Indicates a locally connected FICON channel sent a frame that could not be associated with a FICON device. Recommended Action Contact your vendor's customer support for assistance.
FICN-1042 38 Probable Cause Indicates an LRJ received from a device indicates that the CU has lost the logical path to the LPAR. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
38 FICN-1045 FICN-1045 Message , [FICN-1045], ,, WARNING, , HostTapeIng:FICON Purge received:Path= . Probable Cause Indicates a purge path was received from the locally connected FICON channel. This is performed during the path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
FICN-1049 Probable Cause Indicates the operator has cancelled a read or write job. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance.
38 FICN-1052 Severity INFO FICN-1052 Message , [FICN-1052], ,, INFO, , XRC Session Terminated: SessID=, Path=0x . Probable Cause Indicates a PSF command has been received to break an XRC session with the extended DASD device. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
FICN-1056 38 Probable Cause Indicates a suspend all devices from XRC session PSF command has been received to break an XRC session with the extended DASD device. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
38 FICN-1059 FICN-1059 Message , [FICN-1059], ,, ERROR, , Error return from frame generation for a FICON Image: Path=0x . Probable Cause Indicates an internal resource shortage caused an error such that an emulation frame could not be created and sent to an LPAR. Recommended Action This is an unexpected event, contact your vendor's customer support for assistance.
FICN-1063 38 Probable Cause Indicates an abort operation has been received from the local FC interface for an active emulation exchange. Recommended Action This is an unexpected event, contact your vendor's customer support for assistance.
38 FICN-1066 FICN-1066 Message , [FICN-1066], ,, WARNING, , MemAllocFailed for GEPort= VEport= could not create required structure. Probable Cause Indicates an internal resource limit has been encountered such that additional control block memory could not be allocated.
FICN-1070 Recommended Action Severity 38 If resolution of the configuration issue cannot be completed, contact your vendor's customer support for assistance. ERROR FICN-1070 Message , [FICN-1070], ,, INFO, , DevTapeIngr:Exceptional Status rcvd on Path= state=0x status=0x.
38 FICN-1073 FICN-1073 Message , [FICN-1073], ,, INFO, , HostTapeIngr:Unloaded:Path= :states=0x<4 prior emulation states>:cmds=0x:status=0x:flags=0x.
FICN-1076 Severity 38 INFO FICN-1076 Message , [FICN-1076], ,, INFO, , HostTapeIngr:ReadCpReport:Path= :Emuls=0x:Cmds=0x:Chains=0x:MBytes=
38 FICN-1079 Recommended Action Severity No action is required.
FICN-1082 Recommended Action Severity 38 This is normally an unexpected event, contact your vendor's customer support for assistance. WARNING FICN-1082 Message , [FICN-1082], ,, WARNING, , EmulEls:CSWR_RSCN received on GEPort= VEPort= Domain=0x Port=0x. Probable Cause Indicates an attached port which had a FICON emulated path established has logged out from the switch.
38 FICN-1086 Probable Cause Indicates a FICON FCIP tunnel has been established successfully to the peer switch. Recommended Action No action is required. Severity INFO FICN-1086 Message , [FICN-1086], ,, ERROR, , FICON FCIP Tunnel is Down on GE,tunnel Id=. Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated.
FICN-1089 38 FICN-1089 Message , [FICN-1089], ,, WARNING, , DevTeraEgr:FICON Tera Cancel:Path=0x Elapsed Time= seconds. Probable Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation.
38 FICN-1092 FICN-1092 Message , [FICN-1092], ,, ERROR, , DevTeraEgr:FICON Purge received Path=0x. Probable Cause Indicates the FICON channel issued a Purge Path command sequence for a device. Recommended Action If there was an unexpected job failure or IO Error associated with this event, contact your vendor's customer support for assistance.
FICN-1096 Recommended Action Severity 38 If there was an unexpected job failure or IO Error associated with this event, contact your vendor's customer support for assistance.
38 FICN-1099 FICN-1099 Message , [FICN-1099], ,, ERROR, , HostTeraIng::FICON Selective Reset:Path=0x state=0x LastCmds=0x LastStatus=0x.
FICN-1102 38 FICN-1102 Message , [FICN-1102], ,, WARNING, , HostTeraIng:LRJ received on Path=0x lastCmds=0x lastStatus=0x treating as system reset event.
38 FICN-1105 FICN-1105 Message , [FICN-1105], ,, WARNING, , DevTeraIng:LRJ received on Path=0x lastCmds=0x lastStatus=0x treating as system reset event.
FICN-2065 Recommended Action Severity 38 If there were associated IO errors at the same time as this event, contact your vendor's customer support for assistance. INFO FICN-2065 Message , [FICN-2065], ,, INFO, , Egress Abort:Oxid=0x:Unknown Path on VEPort= from SID=0x to DID=0x.
38 FICN-2083 FICN-2083 Message , [FICN-2083], ,, WARNING, , EmulEls:SW_RSCN received on VEPort= Domain=0x Port=0x. Probable Cause Indicates an attached port with the established FICON emulated path has logged out from the switch. Recommended Action This may be an unexpected event, contact your vendor's customer support for assistance.
Chapter FICU System Messages 39 FICU-1001 Message , [FICU-1001], ,, ERROR, , : config failed rc = . Probable Cause Indicates that one of the configuration management functions failed. The key variable is a part of the Fabric OS configuration database and is for support use only. The error variable is an internal error number.
39 FICU-1004 Severity WARNING FICU-1004 Message Probable Cause , [FICU-1004], ,, WARNING, , : Failed to set fabric manager server (FMS) mode: conflicting PID Format:, FMS Mode:. Indicates that a process ID (PID) format conflict was encountered. The core PID format is required for fibre connectivity control unit port (FICON-CUP).
FICU-1007 Recommended Action Severity 39 Check if the FICON channel corresponding to the PID in the message is functioning correctly. WARNING FICU-1007 Message , [FICU-1007], ,, WARNING, , : Failed to allocate memory while performing . Probable Cause Indicates that memory resources are low. This might be a transient problem. Recommended Action If the message persists, check the memory usage on the switch, using the memShow command.
39 FICU-1010 FICU-1010 Message , [FICU-1010], ,, WARNING, , FMS Mode enable failed due to port(s) with areas 0xFE or 0xFF is(are) connected to device(s). Probable Cause Indicates that the Fibre Connectivity (FICON) Management Server mode (fmsMode) was not enabled because ports with areas 0xFE or 0xFF are connected to devices. Recommended Action Use the portDisable command to disable ports with areas 0xFE or 0xFF.
FICU-1017 39 FICU-1017 Message , [FICU-1017], ,, WARNING, , FMSMODE enable failed because reserved area is bound to a device. Probable Cause Indicates one or both of the reserved areas 0xFE and 0xFF is bound to a device. Recommended Action Run the wwnaddress --show command to see all the devices currently bound to areas. Use wwnaddress --unbind [WWN] command to release the reserved area from the device.
39 FICU-1021 FICU-1021 Message , [FICU-1021], ,, INFO, , Port Addrs (%s) have been UnBlocked by %s. Probable Cause Indicates the Fibre Connectivity (FICON) Management server has unblocked ports. Recommended Action No action is required. Severity INFO FICU-1022 Message , [FICU-1022], ,, ERROR, , Detected FC8-48 and/or FC8-64 that are not manageable when FMS mode is enabled.
Chapter FKLB System Messages 40 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it automatically recovers after the application times the exchange out. Recommended Action No action is required.
40 308 FKLB-1001 Fabric OS Message Reference 53-1002149-01
Chapter FLOD System Messages 41 FLOD-1001 Message , [FLOD-1001], ,, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link state record (LSR) type is unknown. The following two LSR header types are the only known types: 1 - Unicast and 3 - Multicast. Recommended Action No action is required because the record is discarded.
41 FLOD-1005 FLOD-1005 Message , [FLOD-1005], ,, WARNING, , Invalid received domain ID: . Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended Action No action is required because the LSR is discarded. Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: .
Chapter FSPF System Messages 42 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range as it does not exist on the switch. Recommended Action No action is required.
42 FSPF-1005 FSPF-1005 Message , [FSPF-1005], ,, ERROR, , Wrong Section Id , should be , input port = Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID.
FSPF-1009 Recommended Action Severity 42 No action is required. INFO FSPF-1009 Message , [FSPF-1009], ,, ERROR, , 16G ICL topology is invalid on local domain . Probable Cause Indicates that the current 16G ICL topology is invalid and cannot be routed. Recommended Action Use the topologyShow command to report the invalid routes and correct as appropriate.
42 314 FSPF-1009 Fabric OS Message Reference 53-1002149-01
Chapter FSS System Messages 43 FSS-1001 Message , [FSS-1001], , SLOT cp-slot-number | CHASSIS, WARNING, , Component () dropping HA data update (). Probable Cause Indicates that an application has dropped a high availability (HA) data update. Recommended Action Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed system.
43 FSS-1004 If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1004 Message , [FSS-1004], , SLOT cp-slot-number | CHASSIS, ERROR, , Memory shortage Probable Cause Indicates that the system ran out of memory. Recommended Action Run the memShow command to view memory usage.
FSS-1008 43 Probable Cause Indicates that the Ethernet connection between the active control processor (CP) and standby CP is not healthy. The error occurs when the standby CP does not respond to a request from the active CP within five seconds. This usually indicates a problem with the internal Ethernet connection and a disruption of the synchronization process.
43 FSS-1011 FSS-1011 Message , [FSS-1011], , SLOT cp-slot-number | CHASSIS, INFO, , FSS Info: . Probable Cause Indicates an informational message only. Recommended Action No action is required.
Chapter FSSM System Messages 44 FSSM-1002 Message , [FSSM-1002], , SLOT cp-slot-number | CHASSIS, INFO, , HA State is in sync. Probable Cause Indicates that the high availability (HA) state for the active control processor (CP) is in synchronization with the HA state of the standby CP. If the standby CP is healthy, then a failover is nondisruptive. For more information on the haFailover command, refer to the Fabric OS Command Reference Manual.
44 FSSM-1004 FSSM-1004 Message , [FSSM-1004], , SLOT cp-slot-number | CHASSIS, INFO, , Incompatible software version in HA synchronization. Probable Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade or downgrade was invoked.
Chapter FW System Messages 45 FW-1001 Message , [FW-1001], ,, INFO, ,
45 FW-1004 Severity WARNING FW-1004 Message , [FW-1004], ,, INFO, ,
FW-1011 45 FW-1011 Message , [FW-1011], ,, INFO, ,
45 FW-1035 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. WARNING FW-1035 Message , [FW-1035], ,, WARNING, ,
FW-1038 45 FW-1038 Message , [FW-1038], ,, WARNING, ,
45 FW-1041 FW-1041 Message , [FW-1041], ,, INFO, ,
FW-1044 45 FW-1044 Message , [FW-1044], ,, INFO, ,
45 FW-1048 Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high boundary. Recommended Action The supplied current of the SFP transceiver is outside of the normal range, indicating possible hardware failure. If the current rises above the high boundary, you must replace the SFP.
FW-1051 45 FW-1051 Message , [FW-1051], ,, WARNING, ,
45 FW-1113 Recommended Action Severity Replace the SFP. WARNING FW-1113 Message , [FW-1113], ,, INFO, ,
FW-1116 45 FW-1116 Message , [FW-1116], ,, INFO, ,
45 FW-1119 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1119 Message Probable Cause , [FW-1119], ,, INFO, ,
FW-1122 45 Probable Cause Indicates that the number of domain ID changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
45 FW-1125 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1125 Message , [FW-1125], ,, INFO, ,
FW-1127 45 FW-1127 Message Probable Cause , [FW-1127], ,, INFO, ,
45 FW-1130 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1130 Message , [FW-1130], ,, INFO, ,
FW-1133 45 FW-1133 Message , [FW-1133], ,, INFO, ,
45 FW-1137 Probable Cause Indicates that the number of fabric logins has changed from a value outside of the acceptable range to a value within the acceptable range. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
FW-1140 45 FW-1140 Message , [FW-1140], ,, INFO, ,
45 FW-1162 FW-1162 Message , [FW-1162], ,, WARNING, , ,
FW-1165 Severity 45 INFO FW-1165 Message , [FW-1165], ,, INFO, , ,
45 FW-1168 FW-1168 Message , [FW-1168], ,, INFO, , ,
FW-1172 45 Probable Cause Indicates that the number of signal losses that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Loss of signal generally indicates a physical problem. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent loss of signal generally indicates a physical problem. Check both ends of your cable connection.
45 FW-1175 Probable Cause Indicates that the number of protocol errors that the port experiences has risen above the high boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended Action Check both ends of your connection. Verify that your cable and small form-factor pluggable (SFP) are not faulty.
FW-1178 Severity 45 INFO FW-1178 Message , [FW-1178], ,, WARNING, , ,
45 FW-1181 FW-1181 Message , [FW-1181], ,, INFO, , ,
FW-1185 45 Probable Cause Indicates that the percentage of incoming traffic that the port experiences has changed. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Severity INFO FW-1185 Message , [FW-1185], ,, INFO, , ,
45 FW-1188 FW-1188 Message , [FW-1188], ,, INFO, , ,
FW-1192 Recommended Action Severity 45 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1192 Message , [FW-1192], ,, INFO, , ,
45 FW-1195 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. WARNING FW-1195 Message , [FW-1195], ,, INFO, , ,
FW-1198 45 FW-1198 Message , [FW-1198], ,, WARNING, , ,
45 FW-1202 Probable Cause Indicates that the number of C3 transmit time out frames is below low threshold. Recommended Action Respond to this message as it is appropriate to the particular policy of the end-user installation. A low number of C3 discard means that the switch is functioning normally. Severity INFO FW-1202 Message , [FW-1202], ,, WARNING, FW, , ,
FW-1205 45 FW-1205 Message , [FW-1205], ,, INFO, , ,
45 FW-1245 Severity INFO FW-1245 Message , [FW-1245], ,, INFO, ,
FW-1248 45 FW-1248 Message , [FW-1248], ,, INFO, ,
45 FW-1272 Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed from a value outside of the acceptable range to a value within the acceptable range. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
FW-1275 Recommended Action Severity 45 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1275 Message , [FW-1275], ,, INFO, ,
45 FW-1298 Severity INFO FW-1298 Message , [FW-1298], ,, WARNING, ,
FW-1301 Severity 45 INFO FW-1301 Message , [FW-1301], ,, INFO, ,
45 FW-1308 Severity INFO FW-1308 Message , [FW-1308], ,, INFO, ,
FW-1334 45 FW-1334 Message , [FW-1334], ,, WARNING, ,
45 FW-1337 FW-1337 Message , [FW-1337], ,, INFO, ,
FW-1340 45 Probable Cause Indicates that the number of device cable connection (DCC) violations has changed from a value outside of the acceptable range to a value within the acceptable range. DCC violations indicate that an unauthorized device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports.
45 FW-1343 Recommended Action Severity Run the errShow command to determine the IP location of the login attempt. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. WARNING FW-1343 Message , [FW-1343], ,, INFO, ,
FW-1352 45 Probable Cause Indicates that the number of invalid signatures has risen above the high boundary. Invalid-signature violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch.
45 FW-1354 FW-1354 Message , [FW-1354], ,, WARNING, ,
FW-1357 Severity 45 INFO FW-1357 Message , [FW-1357], ,, INFO, ,
45 FW-1364 Severity INFO FW-1364 Message , [FW-1364], ,, INFO, ,
FW-1368 Recommended Action Severity 45 No action is required. INFO FW-1368 Message , [FW-1368], ,, INFO, ,
45 FW-1371 Probable Cause Indicates that the number of no-FCS violations has risen above the high boundary. This counter records how often the switch loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the world wide name (WWN) of that primary FCS switch.
FW-1373 45 FW-1373 Message , [FW-1373], ,, INFO, ,
45 FW-1376 FW-1376 Message , [FW-1376], ,, INFO, ,
FW-1379 Severity 45 WARNING FW-1379 Message , [FW-1379], ,, INFO, ,
45 FW-1402 FW-1402 Message , [FW-1402], ,, WARNING, FW, ,
FW-1406 Recommended Action Severity 45 No action is required. INFO FW-1406 Message , [FW-1406], ,, CRITICAL, FW, ,
45 FW-1425 Recommended Action Severity Run the switchStatusShow command to determine the policy violation. WARNING FW-1425 Message , [FW-1425], ,, INFO, , Switch status changed from to HEALTHY. Probable Cause Indicates that the switch status has changed to a healthy state. This occurred because a policy is no longer violated. Recommended Action No action is required.
FW-1428 45 FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the missing power supply.
45 FW-1432 Recommended Action Severity Replace the faulty or deteriorating fan field-replaceable units (FRUs). WARNING FW-1432 Message , [FW-1432], ,, WARNING, , Switch status change contributing factor WWN: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty world wide name (WWN) cards is greater than or equal to the policy set by the switchStatusPolicySet command.
FW-1435 Recommended Action Severity 45 Replace the faulty blade. WARNING FW-1435 Message , [FW-1435], ,, WARNING, , Switch status change contributing factor Flash: usage out of range. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the flash usage is out of range. The policy was set using the switchStatusPolicySet command. Recommended Action Run the supportSave command to clear out the kernel flash.
45 FW-1438 Severity WARNING FW-1438 Message , [FW-1438], ,, WARNING, , Switch status change contributing factor Missing SFPs: missing out of SFPs:config( percent,). (Port(s) ). Probable Cause Indicates that the switch status is not in a healthy state.
FW-1442 45 Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to inserted. This means that an FRU is inserted but not powered on. Recommended Action No action is required. Verify that the event was planned. Severity INFO FW-1442 Message , [FW-1442], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to on.
45 FW-1446 Probable Cause Indicates that the switch now requires 4 power supplies and previous Switch Status Policy parameters will be overwritten to reflect this. The presence of an AP blade means that more than one power supply may be required to provide adequate power. So (even if the AP blade is powered down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to maintain full (2X) redundancy.
FW-1500 45 Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty ports are greater than or equal to the policy set by the switchStatusPolicySet command. A port is faulted because of port segmentation or port disable. Recommended Action Execute the switchShow command to know the reason for port segmentation and port disable. Take necessary action to bring the port up.
45 FW-1510 FW-1510 Message , [FW-1510], ,, WARNING, , threshold exceeded(High=). Current value is : Port disabled. Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple link failures that exceed Fabric Watch threshold on the port. Both physical and hardware problems can cause link failures.
FW-1513 Severity 45 INFO FW-1513 Message , [FW-1513], ,, INFO, , ,
45 FW-1516 FW-1516 Message , [FW-1516], ,, INFO, , ,
FW-1519 45 FW-1519 Message , [FW-1519], ,, INFO, , ,
45 FW-1522 FW-1522 Message , [FW-1522], ,, INFO, , ,
FW-1526 45 Probable Cause Indicates that the percentage of outgoing traffic that the port experiences has changed and crossed lower threshold boundary to a value within the acceptable range. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
45 FW-1529 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1529 Message , [FW-1529], ,, INFO, , ,
FW-1532 45 FW-1532 Message , [FW-1532], ,, INFO, , ,
45 FW-3010 Recommended Action Severity No action is required. You are informed that PF bit is reset. INFO FW-3010 Message , [FW-3010], ,, INFO, , ,
FW-3014 Probable Cause Indicates that the circuit utilization is in-between high and low threshold. Recommended Action No action required. Severity 45 INFO FW-3014 Message , [FW-3014], ,, INFO, , ,
45 FW-3017 FW-3017 Message , [FW-3017], ,, INFO, , ,
FW-3021 45 Probable Cause Indicates the number of state changes that the circuit experiences has increased above the high boundary. The state of the circuit has changed for the reason that the circuit has gone offline, it has come online, or it is testing. Recommended Action No action is required. Severity WARNING FW-3021 Message , [FW-3021], ,, WARNING, , ,
45 396 FW-3022 Fabric OS Message Reference 53-1002149-01
Chapter HAM System Messages 46 HAM-1001 Message , [HAM-1001], , SLOT cp-slpt-number | FFDC | CHASSIS, FFDC, CRITICAL, , Standby CP is not healthy, device status BAD, Severity = Probable Cause Indicates that a standby control processor (CP) device error is reported by the high-availability manager (HAM) Health Monitor, with a specific device and Log="YES” Class=”NONE" Severity level.
46 HAM-1005 • • • • • • • • • • • • • • • • • • Recommended Action Severity Fastboot Giveup Master:SYSM CP Faulty:SYSM FirmwareDownload ConfigDownload:MS ChangeWWN:EM Reboot:WebTool Fastboot:WebTool Software Fault:Software Watchdog Software Fault:Kernel Panic Software Fault:ASSERT Reboot:SNMP Fastboot:SNMP Reboot Chassis Config Reboot:API Reboot:HAM EMFault:EM Check the error log on both CPs for additional messages that might indicate the reason for the reboot.
HAM-1007 Recommended Action Severity 46 The standby CP will take over and reset the active CP. The system will be non-redundant as the standby becomes the active CP. Run the supportSave command and contact your switch service provider. CRITICAL HAM-1007 Message , [HAM-1007], , SLOT cp-slpt-number | FFDC | CHASSIS, FFDC, CRITICAL, , Need to reboot the system for recovery, reason: .
46 HAM-1010 HAM-1010 Message , [HAM-1010], , SLOT cp-slot-number | CHASSIS, CRITICAL, , Please maunually trigger hareboot/reboot for recovery from OOM when appropriate. Probable Cause Indicates OOM is detected when system is not ready for warm recovery. Recommended Action Manually trigger reboot for cold recovery if needed, or wait until system is ready and use hareboot/hafailover to trigger warm recovery.
HAM-1014 Severity 46 CRITICAL HAM-1014 Message , [HAM-1014], , SLOT cp-slot-number | CHASSIS, CRITICAL, . Probable Cause Indicates a software watchdog detected termination of a restartable daemon and needed to reboot/failover. Recommended Action If needed manually initiate a reboot/failover.
46 402 HAM-1014 Fabric OS Message Reference 53-1002149-01
Chapter HAMK System Messages 47 HAMK-1001 Message , [HAMK-1001], , SLOT cp-slot-number | CHASSIS, FFDC, CRITICAL, , Warm recovery failed. Probable Cause Indicates the switch failed during the warm recovery. Recommended Action This message triggers a switch reboot automatically and attempts a cold recovery. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
47 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], , SLOT cp-slot-number | CHASSIS, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the standby CP has been rebooted. Note that in certain circumstances a CP may experience a double reset and reboot twice in a row.
Chapter HIL System Messages 48 HIL-1101 Message , [HIL-1101], ,, ERROR, , Slot faulted, () is above threshold. Probable Cause Indicates that the blade voltage is above threshold. Recommended Action Replace the faulty blade or switch (for nonbladed switches).
48 HIL-1104 HIL-1104 Message , [HIL-1104], ,, ERROR, , Blower faulted, () is below threshold. Probable Cause Indicates that the fan voltage is below threshold. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are seated properly.
HIL-1107 48 HIL-1107 Message , [HIL-1107], , FFDC, CRITICAL, , Switch faulted, ()above threshold. System preparing for reset. Probable Cause Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
48 HIL-1202 If the fan continues to generate this message, replace the fan FRU. Severity WARNING HIL-1202 Message , [HIL-1202], ,, ERROR, , Blower faulted, speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. Recommended Action Replace the fan FRU.
HIL-1206 48 HIL-1206 Message , [HIL-1206], ,, ERROR, , Fan sensor , speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
48 HIL-1301 HIL-1301 Message , [HIL-1301], ,, WARNING, , 1 blower failed or missing. Replace failed or missing blower assembly immediately. Probable Cause Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Action Replace the affected fan FRU immediately.
HIL-1305 Severity 48 ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan FRUs immediately. Severity ERROR HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed.
48 HIL-1309 Recommended Action Severity Replace the faulty fan field-replaceable units (FRUs) immediately. ERROR HIL-1309 Message , [HIL-1309], ,, ERROR, , fan FRUs failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan field-replaceable unit (FRU)s immediately.
HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Action Install the missing fan FRU. Severity 48 WARNING HIL-1402 Message , [HIL-1402], ,, WARNING, , Two fan FRUs missing. Install fan FRUs immediately. Probable Cause Indicates that two fan field-replaceable units (FRUs) have been removed. Recommended Action Install the missing fan FRUs immediately.
48 HIL-1502 Recommended Action Severity Run the fanShow command to verify all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. WARNING HIL-1502 Message , [HIL-1502], , FFDC, CRITICAL, , Slot , high temperature ().
HIL-1505 Recommended Action Severity 48 No action is required. INFO HIL-1505 Message , [HIL-1505], ,, WARNING, , High temperature ( C) fan speed increasing per environmental specifications. Probable Cause Indicates that temperatures in the system have risen above the warning threshold and the fan speed is increased. Recommended Action Run the fanShow command to verify all the fans are working properly.
48 HIL-1508 Severity CRITICAL HIL-1508 Message , [HIL-1508], , FFDC, CRITICAL, , Fan faulty warning time expired. System preparing for shutdown. Probable Cause Indicates that temperatures in the system have remained above the critical threshold too long. Recommended Action To avoid causing damage to the switch, the system shuts down automatically. To help prevent future problems, make sure that all the fans are working properly.
HIL-1601 48 HIL-1601 Message , [HIL-1601], ,, ERROR, , Using backup temperature sensor. Attention needed. Probable Cause Indicates that temperature readings from the primary sensor are out of range. Recommended Action Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating fan field-replaceable units (FRUs). Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch.
48 HIL-1610 Recommended Action Severity No action required. INFO HIL-1610 Message , [HIL-1610], ,, WARNING, , Fan/PS unit not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on. Probable Cause Indicates that the power supply is not connected to a power source or it is not switched on or the unit is faulty. Applicable only to Brocade 5100 and Brocade 6510.
HIL-1613 48 HIL-1613 Message , [HIL-1613], ,, INFO, , PSU-FAN FRUS Air Flow matched. System shutdown canceled. Probable Cause Indicates that PSU FAN Air Flows have changed to same direction. System can continue operation. Applicable only to Brocade 6510. Recommended Action Ensure that the fan units have same direction.
48 420 HIL-1650 Fabric OS Message Reference 53-1002149-01
Chapter HLO System Messages 49 HLO-1001 Message , [HLO-1001], , FFDC, ERROR, , Incompatible Inactivity timeout from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch.
49 HLO-1003 The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action Severity 422 The HLO message of the remote switch must be compatible with the value specified in the FSPF protocol. Refer to the documentation for the other manufacturer's switch to change this value.
Chapter HMON System Messages 50 HMON-1001 Message , [HMON-1001], , FFDC, CRITICAL, , Probable Cause Indicates there was a problem reading an essential file containing configuration information from the nonvolatile storage device. This could be the result of a missing file or a corrupt file system. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch.
50 424 HMON-1001 Fabric OS Message Reference 53-1002149-01
Chapter HSL System Messages 51 HSL-1000 Message , [HSL-1000], ,, CRITICAL, , HSL initialization failed. Probable Cause Indicates an HSL initialization failure. Recommended Action No action is required. Severity CRITICAL HSL-1001 Message , [HSL-1001], ,, CRITICAL, , Failed to acquire system mac address pool. Probable Cause Indicates the failure to acquire a system address.
51 HSL-1004 Recommended Action Severity No action is required. INFO HSL-1004 Message , [HSL-1004], ,, ERROR, , Incompatible SFP for interface is detected. Probable Cause Indicates an incompatible SFP for the interface has been inserted. Recommended Action Use the correct SFP for this interface. Severity ERROR HSL-1005 Message , [HSL-1005], ,, CRITICAL, , Failed to initialize with FSS.
HSL-1007 Recommended Action Severity 51 No action is required.
51 428 HSL-1007 Fabric OS Message Reference 53-1002149-01
Chapter HTTP System Messages 52 HTTP-1001 Message , [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that the PID format was changed by the administrator. Recommended Action No action is required. For more information on PID format, refer to the Fabric OS Administrator’s Guide.
52 430 HTTP-1003 Fabric OS Message Reference 53-1002149-01
Chapter IBD System Messages 53 IBD-1000 Message , [IBD-1000], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power off and power on the blade using the slotPowerOff and slotPowerOn commands.
53 432 IBD-1000 Fabric OS Message Reference 53-1002149-01
Chapter IBPD System Messages 54 IBPD-1001 Message , [IBPD-1001], ,, WARNING, , : initiator name length exceeds the character limit [] Probable Cause Indicates that the initiator name length exceeds the supported limit of characters. Recommended Action Change the initiator name, keeping the number of characters within the supported limit.
54 434 IBPD-1003 Fabric OS Message Reference 53-1002149-01
Chapter ICPD System Messages 55 ICPD-1001 Message , [ICPD-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Severity Reboot or power cycle the switch.
55 ICPD-1005 Recommended Action Severity Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer to the Fabric OS Command Reference for more information on this command. WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, , iSCSI configuration between local switch () and peer () is out of sync. iSCSI login is not allowed.
ICPD-1008 Recommended Action Severity 55 No action is required.
55 438 ICPD-1008 Fabric OS Message Reference 53-1002149-01
Chapter IPAD System Messages 56 IPAD-1000 Message , [IPAD-1000], ,, INFO, , . Probable Cause Indicates that a change in the local IP address has occurred.
56 IPAD-1003 Severity INFO IPAD-1003 Message , [IPAD-1003], ,, INFO, , DNS parameters saved successfully. Probable Cause Indicates that the DNS parameters are saved successfully. Recommended Action No action is required. Severity INFO IPAD-1004 Message , [IPAD-1004], ,, INFO, , DNS parameters removed successfully. Probable Cause Indicates that the DNS parameters are removed successfully.
Chapter IPS System Messages 57 IPS-1001 Message , [IPS-1001], ,, WARNING, , FCIP License Not Installed () Probable Cause Indicates that the FCIP license is not installed on the switch. Recommended Action Run the licenseShow command to check the installed licenses on the switch. Contact your switch supplier for a FCIP license. Run the licenseAdd command to add the license to your switch.
57 IPS-1005 Probable Cause Indicates that configured Port Mode is different from the intended use. Recommended Action Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port mode to neutral before attempting to configure the port for a different mode or use.
Chapter ISCS System Messages 58 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended Action No action is required; the port will restart automatically.
58 444 ISCS-1000 Fabric OS Message Reference 53-1002149-01
Chapter ISNS System Messages 59 ISNS-1001 Message , [ISNS-1001], ,, INFO, , Configuration peering with external iSNS server slot/port /ge (current /ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended Action No action is required.
59 ISNS-1004 ISNS-1004 Message , [ISNS-1004], ,, WARNING, , Timeout refreshing iSNS database with iSNS server slot/port /ge Reg-Period . Probable Cause Indicates that the internet storage name service (iSNS) client failed to receive a successful response for a DevAttrQry within the specified Registration-Period.
ISNS-1009 Recommended Action Severity 59 No action is required. You may change the configuration and retry the peering with the external iSNS server. INFO ISNS-1009 Message , [ISNS-1009], ,, INFO, , Peering with external iSNS server not started because no virtual targets found. Probable Cause Indicates that no virtual targets were found, so peering was not started. Recommended Action No action is required.
59 ISNS-1013 ISNS-1013 Message , [ISNS-1013], ,, WARNING, , iSNS server connection failure. Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Action Verify the connection of the iSNS server to the slot or port. Use the isnscCfg command to display or correct the server IP address.
Chapter KAC System Messages 60 KAC-1002 Message , [KAC-1002], ,, ERROR, , KAC() communication Error: Error connecting to . Probable Cause Indicates that the key archival client is unable to communicate with the primary or backup key vault. Recommended Action Determine whether the configured key vault is operational, and if it is not, change the switch key vault settings or resolve the operational problem at the vault.
60 KAC-1008 Probable Cause Indicates that the key archival client is unable to put to the primary or backup key vault. Recommended Action Determine whether the configured key value is operational, and if it is not, change the switch key vault settings or resolve the operational problem at the vault.
KAC-1011 60 KAC-1011 Message , [KAC-1011], ,, WARNING, , Putting the dummy DEK to the KV failed. Dummy DEK: , KeyCount: . Error code=, string=. Probable Cause Indicates that putting the Dummy failed to keyvault. Recommended Action No action is required.
60 KAC-1015 Severity WARNING KAC-1015 Message , [KAC-1015], ,, ERROR, , KAC() communication Error: Error connecting to . Error code=, string=. Probable Cause Indicates that key archival client is unable to communicate with the primary or backup key vault. Recommended Action Change the switch key vault settings and/or ensure that the configured key vault is operational.
Chapter KSWD System Messages 61 KSWD-1001 Message , [KSWD-1001], , FFDC, WARNING, , : failed to refresh (:). Probable Cause Indicates that one of the critical daemons is found to be nonresponsive. An abort signal is sent. Recommended Action Copy the warning message along with any core file information, and contact your switch service provider.
61 454 KSWD-1002 Fabric OS Message Reference 53-1002149-01
Chapter KTRC System Messages 62 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Cause Indicates the dump memory size has exceeded the dump file size. Recommended Action No action is required. Severity WARNING KTRC-1002 Message , [KTRC-1002], ,, INFO, , Concurrent trace dumping. Probable Cause Indicates the initial background dump has not completed.
62 KTRC-1005 Recommended Action Severity No action is required. ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to initialize. Recommended Action No action is required.
Chapter L2SYS System Messages 63 L2SS-1001 Message , [L2SS-1001], ,, ERROR, , Socket Error: for socket the error code . Probable Cause Indicates an error has occurred in the Linux socket. Recommended Action Restart the l2sysd daemon. Severity ERROR L2SS-1002 Message , [L2SS-1002], ,, ERROR, , Initialization error: .
63 L2SS-1005 Recommended Action Severity Restart the l2sysd daemon. ERROR L2SS-1005 Message , [L2SS-1005], ,, ERROR, , Mac-address-table hash failed even after two attempts for slot chip . Probable Cause Indicates a mac-address-table hash failure happened even after two hash changes on the chip. Recommended Action Restart the l2sysd daemon.
L2SS-1008 Recommended Action Severity 63 Clear some of the ACL entries.
63 460 L2SS-1008 Fabric OS Message Reference 53-1002149-01
Chapter LACP System Messages 64 LACP-1001 Message , [LACP-1001], ,, ERROR, , Error opening socket (). Probable Cause Indicates that the initialization of a module within the LACP daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command.
64 462 LACP-1002 Fabric OS Message Reference 53-1002149-01
Chapter LANCE System Messages 65 LANCE-1000 Message , [LANCE-1000], ,, ERROR, , Slot Port GE : Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the port is disabled. Recommended Action No action is required.
65 464 LANCE-1000 Fabric OS Message Reference 53-1002149-01
Chapter LFM System Messages 66 LFM-1001 Message , [LFM-1001], ,, INFO, , The Logical Fabric Manager service is disabled. Probable Cause Indicates that the Logical Fabric Manager service is disabled. Note that the Logical Fabric Manager service is enabled by the factory setting and it is not user configurable. Recommended Action No action is required.
66 LFM-1004 LFM-1004 Message , [LFM-1004], , FFDC, CRITICAL, , HA is out of sync for opcode , error value . Probable Cause Indicates the trigger for some internal logging purpose. Recommended Action Send the ffdc log to the support. Severity CRITICAL LFM-1005 Message , [LFM-1005], ,, WARNING, , Logical port disabled with reason ().
Chapter LOG System Messages 67 LOG-1000 Message , [LOG-1000], ,, INFO, , Previous message repeated times. Probable Cause Indicates the previous message repeated the specified number of times. Recommended Action No action is required. Severity INFO LOG-1001 Message , [LOG-1001], , FFDC, WARNING, , A log message was dropped. Probable Cause Indicates a log message was dropped.
67 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended Action No action is required. Severity INFO LOG-1004 Message , [LOG-1004], ,, INFO, , Log message flooding detected and blocked. Probable Cause Indicates that a message has been flooding and has been blocked.
Chapter LSDB System Messages 68 LSDB-1001 Message , [LSDB-1001], ,, ERROR, , Link State ID out of range. Probable Cause Indicates the specified link state database ID is out of the acceptable range. The valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended Action No action is required.
68 LSDB-1004 Severity CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain . Probable Cause Indicates there is no link state record for the specified local domain. Recommended Action No action is required. The other switch will pass the LSD once the fabric is stable.
Chapter MCAST_SS System Messages 69 MCAST_SS-1001 Message , [MCAST_SS-1001], ,, ERROR, , Socket Error: () for socket the error code. Probable Cause Indicates error encountered in Linux socket. Recommended Action Try restarting the mcast_ssd daemon.
69 MCAST_SS-1005 Recommended Action Severity Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1005 Message , [MCAST_SS-1005], ,, ERROR, , Message error: Invalid message type expecting or or . Probable Cause Indicates that type in the message recieved from driver is invalid. Recommended Action Try restarting the mcast_ssd daemon.
MCAST_SS-1009 Recommended Action Severity 69 Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1009 Message , [MCAST_SS-1009], ,, ERROR, , L2SS error : () vlan mac . Probable Cause Indicates that mcast_ss encountered L2SS related errors. Recommended Action Try restarting the mcast_ssd daemon.
69 MCAST_SS-1013 Recommended Action Severity Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1013 Message , [MCAST_SS-1013], ,, ERROR, , Snooping DB error : () Group Not found - Vlan group . Probable Cause Indicates that the group address lookup for a VLAN failed. Recommended Action Try restarting the mcast_ssd daemon.
MCAST_SS-1017 Recommended Action Severity 69 Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1017 Message , [MCAST_SS-1017], ,, ERROR, , Learning error: () Invalid number for ifindex . Probable Cause Indicates that mcast_ss encountered an error while learning MAC addresses. Recommended Action Try restarting the mcast_ssd daemon.
69 MCAST_SS-1020 Recommended Action Severity 476 Try restarting the mcast_ssd daemon.
Chapter MFIC System Messages 70 MFIC-1001 Message , [MFIC-1001], ,, ERROR, , failure at sysmod_scn registry rc= Probable Cause Indicates the system is temporarily out of resources. Recommended Action No action is required; this message is often transitory. If the message persists, run a switch reboot or an haFailover command (if applicable).
70 MFIC-1003 Recommended Action IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. If you are enabling or disabling IDID mode, this message is for information purposes only, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode check box.
Chapter MPTH System Messages 71 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = . Probable Cause Indicates a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the tree. Recommended Action No action is required. Severity ERROR MPTH-1002 Message , [MPTH-1002], , FFDC, ERROR, , Null lsrP, lsId = .
71 480 MPTH-1003 Fabric OS Message Reference 53-1002149-01
Chapter MQ System Messages 72 MQ-1004 Message Probable Cause , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Indicates an unexpected message has been received in the specified message queue. The queue name is always fspf_q.
72 MQ-1006 MQ-1006 Message , [MQ-1006], ,, WARNING, , queue : msg too long (:) Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended Action No action is required.
Chapter MS System Messages 73 MS-1001 Message , [MS-1001], ,, WARNING, , MS Platform Segmented port= (0x) ( (0x)) Probable Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Action Restart or power cycle the switch.
73 MS-1003 • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. Severity INFO MS-1003 Message Probable Cause , [MS-1003], ,, INFO, , MS detected Unstable Fabric().
MS-1005 Severity 73 INFO MS-1005 Message , [MS-1005], ,, ERROR, , MS Invalid CT Response from d=. Probable Cause Indicates the management server (MS) received an invalid common transport (CT) response from the switch domain. MS expects either a CT accept IU or a reject IU; the MS received neither response, which violates the Fibre Channel Generic Services (FS-GS) specification.
73 MS-1009 MS-1009 Message Probable Cause , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . . Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by the . The following messages will be displayed: • • • • • Recommended Action Severity Exceeded bit error rate threshold Loss of signal or synchronization Not operational seq.
MS-1023 73 MS-1023 Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service . Probable Cause Indicates Management Server Topology Discovery Service is being enabled or disabled. Recommended Action No action is required. Severity INFO MS-1024 Message , [MS-1024], ,, INFO, , Management Server Access Control List is Updated.
73 MS-1027 MS-1027 Message , [MS-1027], ,, INFO, FABRIC, , Fabric Name - configured. Probable Cause Indicates that the fabric name is configured or renamed. Recommended Action This is an informational message and does not require any action. Severity INFO MS-1028 Message , [MS-1028], ,, INFO, FABRIC, , Fabric Name - Cleared. Probable Cause Indicates that the fabric name is cleared.
Chapter MSTP System Messages 74 MSTP-1001 Message , [MSTP-1001], ,, ERROR, , :. Probable Cause Indicates that the system has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Severity Restart or power cycle the switch. ERROR MSTP-1002 Message , [MSTP-1002], ,, ERROR, , :.
74 MSTP-2002 Recommended Action Severity No action is required INFO MSTP-2002 Message , [MSTP-2002], ,, INFO, , . My Bridge ID: Old Root: New Root: Probable Cause Indicates that the MSTP bridge or bridge instance root has changed. Recommended Action No action is required.
MSTP-2006 Recommended Action Severity 74 No action is required. INFO MSTP-2006 Message , [MSTP-2006], ,, INFO, , MSTP instance brigde priority is changed from to . Probable Cause Indicates that the MSTP instance priority has modified. Recommended Action No action is required.
74 492 MSTP-2006 Fabric OS Message Reference 53-1002149-01
Chapter NBFS System Messages 75 NBFS-1001 Message Probable Cause , [NBFS-1001], ,, INFO, , Duplicate E_Port SCN from port in state () Indicates a duplicate E_Port State Change Number was reported.
75 NBFS-1003 Severity ERROR NBFS-1003 Message Probable Cause , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set in state , input , port Indicates the database transmit set flag was not set for the specified input state on the specified port.
Chapter NS System Messages 76 NS-1001 Message , [NS-1001], ,, WARNING, , The response for request 0x from remote switch 0x is larger than the max frame size the remote switch can support! Probable Cause Indicates the response payload exceeds the maximum frame size the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, or v3.
76 NS-1004 Reduce the local device count to follow the capability of the lowest version of firmware. Severity INFO NS-1004 Message , [NS-1004], ,, INFO, , Number of local devices , exceeds the standby can support , can't sync.
NS-1007 76 NS-1007 Message , [NS-1007], ,, WARNING, , NS has detected a logical ISL port in TI zone in fabric . Routing may not be setup correctly. Probable Cause Indicates that a logical ISL is detected in the TI zone. Recommended Action Remove the LISL port from the TI zone because the routing may not be set up correctly.
76 NS-1011 NS-1011 Message , [NS-1011], ,, WARNING, , NS has detected a failover flag disabled TI zone in a base switch in fabric id . Probable Cause Indicates that a failover flag has disabled TI zone in a base switch fabric. Recommended Action Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not be setup correctly.
Chapter NSM System Messages 77 NSM-1001 Message , [NSM-1001], ,, INFO, , Interface is online. Probable Cause Indicates that the interface is online after the protocol dependencies are resolved. Recommended Action No action is required. Severity INFO NSM-1002 Message , [NSM-1002], ,, INFO, , Interface is protocol down.
77 NSM-1005 Recommended Action Severity No action is required. INFO NSM-1005 Message , [NSM-1005], ,, INFO, ,The FCoE VLAN: is in use. First remove all the FCoE sessions of its member ports and then try again to disable it. Probable Cause Indicates that the FCoE VLAN is used in FCoEd. Recommended Action Disable FCoE VLAN by removing all the FCoE sessions from its member ports.
NSM-1009 Recommended Action Severity 77 No action is required. INFO NSM-1009 Message , [NSM-1009], ,, INFO, , Interface is deleted. Probable Cause Indicates that the logical interface has been deleted. Recommended Action No action is required. Severity INFO NSM-1010 Message , [NSM-1010], ,, INFO, , InterfaceMode changed from to for interface .
77 NSM-1013 Recommended Action Severity No action is required. INFO NSM-1013 Message , [NSM-1013], ,, INFO, , Vlan classifier group is deleted. Probable Cause Indicates that Vlan classifier group has been deleted. Recommended Action No action is required. Severity INFO NSM-1014 Message , [NSM-1014], ,, INFO, , Vlan classifier rule is created.
NSM-1017 Recommended Action Severity 77 No action is required. INFO NSM-1017 Message , [NSM-1017], ,, INFO, , Interface is on interface . Probable Cause Indicates that logical interface member list has been changed. Recommended Action No action is required.
77 NSM-1020 Recommended Action Severity 504 No action is required.
Chapter ONMD System Messages 78 ONMD-1000 Message , [ONMD-1000], ,, INFO, , LLDP is enabled. Probable Cause Indicates that LLDP is globally enabled. Recommended Action No action is required. Severity INFO ONMD-1001 Message , [ONMD-1001], ,, INFO, , LLDP is disabled. Probable Cause Indicates that LLDP is globally disabled. Recommended Action No action is required.
78 ONMD-1004 Recommended Action Severity No action is required. INFO ONMD-1004 Message , [ONMD-1004], ,, INFO, , LLDP is disabled on interface . Probable Cause Indicates that LLDP is disabled on interface. Recommended Action No action is required. Severity INFO ONMD-1005 Message , [ONMD-1005], ,, INFO, , Using auto-sense on interface to update dcbx version.
Chapter PDM System Messages 79 PDM-1001 Message , [PDM-1001], ,, WARNING, , Failed to parse the pdm config. Probable Cause Indicates the parity data manager (PDM) process could not parse the configuration file. This might be caused by a missing configuration file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware.
79 PDM-1004 PDM-1004 Message , [PDM-1004], ,, WARNING, , PDM memory shortage. Probable Cause Indicates the parity data manager (PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. Severity If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
PDM-1008 Recommended Action Severity 79 Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1008 Message , [PDM-1008], ,, WARNING, , Failed to get the number of U_Ports. Probable Cause Indicates the parity data manager (PDM) system call to getCfg failed.
79 PDM-1011 PDM-1011 Message , [PDM-1011], ,, WARNING, , File read failed: , Length(read=, expected=), errno=. Probable Cause Indicates the parity data manager (PDM) process could not read data from the specified file. Recommended Action Run the firmwareDownload command to reinstall the firmware.
PDM-1017 Recommended Action Severity 79 Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1017 Message , [PDM-1017], , FFDC, CRITICAL, , System (): . Probable Cause Indicates the specified system call failed.
79 PDM-1022 Probable Cause Indicates a system call failed. Recommended Action Run the firmwareDownload command to reinstall the firmware. Severity If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1022 Message , [PDM-1022], ,, WARNING, , The switch is configured only with IPv6.
PDM-1025 79 PDM-1025 Message , [PDM-1025], ,, WARNING, , IPv6 is configured for LDAP. Probable Cause Indicates that the parity data manager (PDM) cannot synchronize with its peer because the LDAP server is configured for IPv6 addresses. IPv6 is not supported by older firmware. Recommended Action Configure the LDAP server with IPv4 addresses.
79 514 PDM-1026 Fabric OS Message Reference 53-1002149-01
Chapter PDTR System Messages 80 PDTR-1001 Message , [PDTR-1001], ,, INFO, , . Probable Cause Indicates information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved.
80 516 PDTR-1002 Fabric OS Message Reference 53-1002149-01
Chapter PLAT System Messages 81 PLAT-1000 Message , [PLAT-1000], , FFDC, CRITICAL, , Probable Cause Indicates nonrecoverable PCI errors have been detected. Recommended Action The system will be faulted and might automatically reboot. If the system does not reboot, then try issuing the reboot command from a command-line prompt.
81 PLAT-1003 Severity CRITICAL PLAT-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected. Recommended Action The FRU must be replaced.
Chapter PMGR System Messages 82 PMGR-1001 Message , [PMGR-1001], , INFO, LS, , Attempt to create switch succeeded. Probable Cause Indicates that the switch with the specified FID was successfully created. Recommended Action No action is required. Severity INFO PMGR-1002 Message , [PMGR-1002], , WARNING, , Attempt to create switch failed. Error message: .
82 PMGR-1005 Recommended Action Severity No action is required. WARNING PMGR-1005 Message , [PMGR-1005], , INFO, , Attempt to move port(s) to switch succeeded. Probable Cause Indicates the successful attempt to move the ports to the specified switch. Recommended Action No action is required.
PMGR-1009 Recommended Action Severity 82 No action is required. WARNING PMGR-1009 Message , [PMGR-1009], , INFO, ,Attempt to change the base switch to switch succeeded. Probable Cause Indicates the successful change of the base switch. Recommended Action No action is required. Severity INFO PMGR-1010 Message , [PMGR-1010], , WARNING, , Attempt to change the base switch to switch failed.
82 522 PMGR-1011 Fabric OS Message Reference 53-1002149-01
Chapter PORT System Messages 83 PORT-1003 Message , [PORT-1003], ,, WARNING, , Port Faulted because of many Link Failures Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple failures that exceeded an internally set threshold on the port. This problem is typically related to hardware.
83 PORT-1006 Recommended Action Severity Invoke the portCfgLport command to clear the L_port configuration. WARNING PORT-1006 Message , [PORT-1006], ,, INFO, CFG, , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended Action No action is required.
PORT-1010 Recommended Action Severity 83 No action is required. INFO PORT-1010 Message , [PORT-1010], ,, INFO, , Port (ID: ) QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be disabled on a 4G or 8G long distance platform. Recommended Action This is normal; no action required.
83 526 PORT-1010 Fabric OS Message Reference 53-1002149-01
Chapter PS System Messages 84 PS-1000 Message , [PS-1000], , FFDC, CRITICAL, , Failed to initialize Advanced Performance Monitoring. Probable Cause Indicates an unexpected software error has occurred in Advanced Performance Monitoring (APM). The performance monitor has failed to initialize.
84 PS-1004 Probable Cause Indicates that the restoring configuration has failed to set the end-to-end monitoring mask on at least one ISL port. Recommended Action No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled. ISL monitoring can only be disabled through the Fabric Access API.
PS-1007 84 PS-1007 Message , [PS-1007], ,, WARNING, , Failed to add fabricmode toptalker on domain=. . Probable Cause Indicates that FCR or McData mode is enabled on this particular fabric. Recommended Action No action required. Top Talker cannot be installed on fabric with FC router or McData mode enabled. In case if the top talker has to be installed on fabric, FC router and McData mode has to be disabled.
84 530 PS-1008 Fabric OS Message Reference 53-1002149-01
Chapter PSWP System Messages 85 PSWP-1001 Message , [PSWP-1001], ,, INFO, , PID for port and port are swapped. New PID for port is and port is . Probable Cause Indicates that the portSwap command has been issued.
85 PSWP-1004 PSWP-1004 Message , [PSWP-1004], ,, INFO, , Blade Swap complete for slots and . Probable Cause Indicates that the bladeSwap command has been issued. Recommended Action No action is required.
Chapter RAS System Messages 86 RAS-1001 Message , [RAS-1001], ,, INFO, , First failure data capture (FFDC) event occurred. Probable Cause Indicates that a failure data event was captured. Recommended Action Run the supportFtp command (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider.
86 RAS-1006 Probable Cause Indicates an internal software error. Recommended Action Run the supportSave command and contact your switch service provider. Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to remote address ' '. Probable Cause Indicates that the support data file is transferred from the switch automatically.
RAS-2003 Probable Cause Indicates that the audit message log is disabled. Recommended Action No action is required. Severity 86 INFO RAS-2003 Message , [RAS-2003], , INFO, , Audit message class configuration has been changed to . Probable Cause Indicates that the configured classes of the audit feature have been changed. Recommended Action No action is required.
86 RAS-3004 Recommended Action Severity No action is required. WARNING RAS-3004 Message , [RAS-3004], , INFO, , USB storage device disabled. Probable Cause Indicates that the USB storage device is disabled. Recommended Action No action is required.
Chapter RCS System Messages 87 RCS-1001 Message , [RCS-1001], ,, INFO, , RCS has been disabled. Some switches in the fabric do not support this feature. Probable Cause Indicates that the RCS feature has been disabled on the local switch because not all switches in the fabric support RCS or the switch is in nonnative mode. Recommended Action Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.
87 RCS-1004 RCS-1004 Message , [RCS-1004], ,, ERROR, , Application() not registered.() Probable Cause Indicates that a specified application did not register with RCS. Recommended Action Run the haShow command to view the HA state. Run the haDisable and the haEnable commands. Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.1 and later, and v4.1 and later.
RCS-1007 Severity 87 INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates that a domain cannot handle the zone database being committed. Recommended Action Reduce the zone database size.
87 RCS-1011 Recommended Action Severity Configure the remote domain as RCS capable switch. ERROR RCS-1011 Message , [RCS-1011], ,, ERROR, , Remote domain is RCS incapable. Configure this domain as RCS capable. Probable Cause Indicates the remote domain is RCS incapable. Recommended Action Configure the remote domain as RCS capable switch.
Chapter RKD System Messages 88 RKD-1001 Message , [RKD-1001], ,, INFO, , operation . Target: , Initiator: , LUN ID: .\n SessionId:/ Probable Cause Indicates that a First time encryption/re-key/Write Metadata was started/completed/cancelled. Recommended Action No action is required.
88 RKD-1004 Recommended Action Severity Correct the error and resume. CRITICAL RKD-1004 Message , [RKD-1004], ,, INFO, , Message: . Probable Cause Indicates the generic rekey message. Recommended Action No action is required. Severity INFO RKD-1005 Message , [RKD-1005], ,, WARNING, , LUN with LSN: does no have metadata.
Chapter RMOND System Messages 89 RMON-1001 Message , [RMON-1001], ,, INFO, , RMON rising threshold alarm from SNMP OID . Probable Cause Indicates that the threshold level has exceeded for the sample type of RMON alarm. Recommended Action Check the traffic on the interface. Severity INFO RMON-1002 Message , [RMON-1002], ,, INFO, , RMON falling threshold alarm from SNMP OID .
89 544 RMON-1002 Fabric OS Message Reference 53-1002149-01
Chapter RPCD System Messages 90 RPCD-1001 Message , [RPCD-1001], ,, WARNING, , Authentication Error: client \"\" has bad credentials: Probable Cause Indicates an authentication error was reported. The specified client IP address has faulty credentials. Recommended Action Enter the correct user name and password from the Fabric Access API host.
90 RPCD-1004 RPCD-1004 Message , [RPCD-1004], ,, WARNING, , Invalid certificate file. Secure RPCd is disabled. Probable Cause Indicates the SSL certificate file has been corrupted. Recommended Action To enable RPCD in Secure mode, install a valid SSL certificate in the switch. Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing private key file. Secure RPCd is disabled.
Chapter RTE System Messages 91 RTE-1001 Message , [RTE-1001], ,, ERROR, , Detected route inconsistency. If connectivity issues arise, all ISLs connected to this chassis need to be bounced to recover. Probable Cause Indicates hafailover. Recommended Action Reset all E_ports on this chassis.
91 548 RTE-1001 Fabric OS Message Reference 53-1002149-01
Chapter RTWR System Messages 92 RTWR-1001 Message , [RTWR-1001], ,, ERROR, , RTWR 0x, 0x, 0x, 0x, 0x Probable Cause Indicates that an error has occurred in the RTWR. The message provides the name of the routine having the error, and more specific error information. The values from 1 through 5 provide more information. Recommended Action No action is required.
92 RTWR-1003 RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry to domain , iu_data Probable Cause Indicates the number of times the RTWR has failed to get a response. Recommended Action Run the dom command to verify that the specified domain ID is reachable.
Chapter SAS System Messages 93 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid=. Probable Cause The hardware is not responding to the command request; possibly because it is busy. Recommended Action Retry the command.
93 552 SAS-1001 Fabric OS Message Reference 53-1002149-01
Chapter SCN System Messages 94 SCN-1001 Message Probable Cause , [SCN-1001], , FFDC, CRITICAL, , SCN queue overflow for process . Indicates that an attempt to write a state change notification (SCN) message to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or the system being busy. Some valid values for daemon name are listed below.
94 SCN-1002 Probable Cause Indicates that an attempt to write a State Change Notification (SCN) message to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or the system being busy. The following are some of the valid values for the daemon name.
Chapter SEC System Messages 95 SEC-1001 Message , [SEC-1001], ,, ERROR, , RCS process fails: . Probable Cause Indicates that the reliable commit service (RCS) process failed to complete. RCS is a mechanism for transferring data from one switch to other switches within the fabric. RCS ensures that either all or none of the switches commit to the database.
95 SEC-1003 SEC-1003 Message , [SEC-1003], ,, WARNING, , Fail to download security data to domain after retries. Probable Cause Indicates the specified domain has failed to download security data after the specified number of attempts, and that the failed switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries.
SEC-1007 95 SEC-1007 Message , [SEC-1007], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the API connection.
95 SEC-1016 Recommended Action Severity Resolve the above specifed error by executing the command only from Primary FCS. ERROR SEC-1016 Message , [SEC-1016], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish SSH connection. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message.
SEC-1025 95 SEC-1025 Message , [SEC-1025], ,, ERROR, , Invalid IP address () detected. Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
95 SEC-1029 SEC-1029 Message , [SEC-1029], ,, ERROR, , Invalid character in . Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
SEC-1033 95 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state.
95 SEC-1036 Severity ERROR SEC-1036 Message , [SEC-1036], ,, ERROR, , Device name is invalid due to a missing colon. Probable Cause Indicates one or more device names mentioned in the securePolicyCreate or securePolicyAdd command does not have the colon character (:) as required. Recommended Action Run the secPolicyCreate or secPolicyAdd command with a properly formatted device name parameter.
SEC-1041 Severity 95 ERROR SEC-1041 Message Probable Cause , [SEC-1041], ,, ERROR, , Invalid port member in portlist (). . Indicates the port member is invalid for one of the following reasons: • The value is not a number. • The value is too long. Valid numbers must be between one and three characters long. • The value cannot be parsed due to invalid characters.
95 SEC-1045 Probable Cause Indicates the specified member is a duplicate in the input list. The list can be a policy list or a switch member list. Recommended Action Do not specify any duplicates. Severity ERROR SEC-1045 Message , [SEC-1045], ,, ERROR, , Too many port members. Probable Cause Indicates there has been a corruption during the distribution of the security database.
SEC-1050 Recommended Action Severity 95 Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1050 Message , [SEC-1050], ,, ERROR, , There are more than one switches with the same name in the fabric.
95 SEC-1053 Severity ERROR SEC-1053 Message , [SEC-1053], ,, ERROR, , Invalid pFCS list Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1056 95 SEC-1056 Message , [SEC-1056], ,, ERROR, , Invalid position . Only members in list. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database.
95 SEC-1063 Probable Cause Indicates that either no domains or domains more than the maximum number supported are specified. Recommended Action Enter the correct number of domains. Severity ERROR SEC-1063 Message , [SEC-1063], ,, ERROR, , Failed to reset statistics. Probable Cause Indicates that either the type or domains specified are invalid. Recommended Action Enter valid input.
SEC-1071 95 Probable Cause Indicates the security database is corrupted for unknown reasons. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1071 Message , [SEC-1071], ,, ERROR, , No new security policy data to apply. Probable Cause Indicates that no changes in the defined security policy database need to be activated at this time.
95 SEC-1075 Probable Cause Indicates a security command was run on a switch that is not allowed to run it either because it is in non-secure mode or because it does not have the required fabric configuration server (FCS) privilege. Recommended Action If a security operation that is not allowed in non-secure mode is attempted, do not perform the operation in non-secure mode. In secure mode, run the command from a switch that has required privilege, that is, either a backup FCS or primary FCS.
SEC-1078 Severity 95 ERROR SEC-1078 Message , [SEC-1078], ,, ERROR, , No new data to abort. Probable Cause Indicates there are no new changes in the defined security policy database that can be aborted. Recommended Action Verify the security event was planned. Verify if there were really any changes to the defined policy database that can be aborted.
95 SEC-1082 Probable Cause Indicates the device connection control (DCC) policy name given in the secPolicyCreate command was the same as another DCC policy. Recommended Action Make sure that the DCC policy name has a unique alphanumeric string, and run the secPolicyCreate command again. Severity ERROR SEC-1082 Message , [SEC-1082], ,, ERROR, , Failed to create policy.
SEC-1085 95 SEC-1085 Message , [SEC-1085], ,, ERROR, , Failed to create . Probable Cause Indicates that the security policy was not created. Recommended Action Check that the current policy configuration is valid. For example, the RSNMP policy cannot exist without the WSNMP policy. Severity ERROR SEC-1086 Message , [SEC-1086], ,, ERROR, , The security database is too large to fit in flash.
95 SEC-1089 Recommended Action Severity Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1089 Message , [SEC-1089], ,, ERROR, , Policy name was not found. Probable Cause Indicates the security policy name in the secPolicyAdd command does not exist.
SEC-1092 95 SEC-1092 Message , [SEC-1092], ,, ERROR, , Name not found. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
95 SEC-1096 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state.
SEC-1099 95 SEC-1099 Message , [SEC-1099], ,, ERROR, , Please enable your switch before running secModeEnable. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
95 SEC-1104 Probable Cause Indicates the switch failed to download a certificate, security database, or policies. This can happen when the switch does not have enough resources to complete the operation, the fabric has not stabilized, or the policy database is an invalid format. Recommended Action Wait for fabric to become stable and then retry the operation. If the policy database is in an illegal format (with configDownload), correct the format and retry the operation.
SEC-1107 95 SEC-1107 Message , [SEC-1107], ,, INFO, , Stamp is 0. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
95 SEC-1112 Probable Cause Indicates the defined and active fabric configuration server (FCS) policy list failed to have at least one member in common. Recommended Action A new FCS policy list must have at least one member in common with the previous FCS policy. Severity ERROR SEC-1112 Message , [SEC-1112], ,, ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch.
SEC-1115 95 SEC-1115 Message , [SEC-1115], ,, ERROR, , No primary FCS to failover. Probable Cause Indicates that during an attempted secFcsFailover, no primary fabric configurations server (FCS) is present in the fabric. Recommended Action Run the secFabricShow command to verify that all switches in fabric are in the ready state. When all switches are in the ready state, retry the operation.
95 SEC-1119 Recommended Action Severity Usually this problem is transient. Retry the command. INFO SEC-1119 Message , [SEC-1119], ,, INFO, , Secure mode has been enabled. Probable Cause Indicates the secure Fabric OS was enabled by the secModeEnable command. Recommended Action Verify the security event was planned. If the security event was planned, there is no action required.
SEC-1124 95 Probable Cause Indicates the security database was successfully downloaded from the primary fabric configuration server (FCS). Recommended Action No action is required. Severity INFO SEC-1124 Message , [SEC-1124], ,, INFO, , Secure Mode is off. Probable Cause Indicates that a secure mode disable is attempted in a non-secure fabric. Recommended Action No action is required.
95 SEC-1135 SEC-1135 Message , [SEC-1135], ,, INFO, , Secure fabric version stamp has been reset. Probable Cause Indicates the version stamp of the secure fabric is reset. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1138 95 SEC-1138 Message , [SEC-1138], ,, INFO, , Security database download received from Primary FCS. Probable Cause Indicates that a non-primary fabric configuration server (FCS) switch received a security database download. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
95 SEC-1146 Probable Cause Indicates one of the following has occurred: • The names for the specified policies have changed. • The passwords have changed for the specified accounts. • The SNMP community strings have been changed. Recommended Action Severity Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1155 95 Probable Cause Indicates that either the defined or the active policy could not be updated. If the policy database is very large, it might not be able to change the index/area because the new policy database exceeds the maximum size. This message can also be caused when the switch is short of memory. The status values can be either defined, active, or both. A negative value means that a policy set was failed by the daemon. Recommended Action Reduce the size of the policy database.
95 SEC-1158 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name . Probable Cause Indicates the specified name is invalid. The name can be a policy name or a switch name. Recommended Action Enter a valid name.
SEC-1164 95 Probable Cause Indicates the lockdown option was attempted while the fabric is already in secure mode. Recommended Action Do not use lockdown option with the secModeEnable command when a switch is already in secure mode. Severity ERROR SEC-1164 Message , [SEC-1164], ,, ERROR, , Lockdown option cannot be applied on a non-FCS switch.
95 SEC-1167 SEC-1167 Message , [SEC-1167], ,, ERROR, , Another FCS failover is in process. Command terminated. Probable Cause Indicates that because another failover is already in progress, this failover attempt cannot proceed. Recommended Action Verify the security event was planned. If the security event was planned, retry fabric configurations server (FCS) failover after current failover has completed, if this switch should become primary FCS.
SEC-1171 95 SEC-1171 Message , [SEC-1171], ,, ERROR, , Disabled secure mode due to invalid security object. Probable Cause Indicates the switch is segmented, and secure mode is disabled on the switch because there was no license present or no public key infrastructure (PKI) objects. Recommended Action Run the pkiShow command to determine whether all PKI objects exist. If they do not exist, run the pkiCreate command to create them for the switch.
95 SEC-1175 Recommended Action Severity Verify all switches in the fabric are in time synchronization with the primary and that no external entity is trying to access the fabric. When verification is complete, retry the operation. ERROR SEC-1175 Message , [SEC-1175], ,, ERROR, , Failed to install zone data. Probable Cause Indicates the zone database could not be installed on the switch.
SEC-1182 Recommended Action Severity 95 No action is required. INFO SEC-1182 Message , [SEC-1182], ,, INFO, , Recovered accounts. Probable Cause Indicates the specified number of accounts has been recovered from backup. Recommended Action No action is required. Severity INFO SEC-1183 Message , [SEC-1183], ,, ERROR, , Policy to binary conversion error: Port is out range.
95 SEC-1186 Probable Cause Indicates the switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the Remote Authentication Dial-in User Service (RADIUS) / Lightweight Directory Access Protocol (LDAP) is the primary AAA mechanism Recommended Action No action is required. Severity INFO SEC-1186 Message , [SEC-1186], ,, INFO, , Configuration.
SEC-1189 Recommended Action Severity 95 Check the DCC policy and verify the specified device is allowed in the fabric and is included in the DCC policy. If the specified device is not included in the policy, add it to the policy. If the host is not allowed access to the fabric, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy.
95 SEC-1192 Recommended Action Severity Determine whether the host IP address specified in the message can be used to manage the fabric through an HTTP connection. If so, add the host IP address to the HTTP policy of the fabric. If the host is not allowed access to the fabric, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy.
SEC-1195 95 SEC-1195 Message , [SEC-1195], ,, WARNING, , This switch has no license. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
95 SEC-1199 Recommended Action Severity Check to see if the host IP address specified in the message can be used to manage the fabric through an API connection. If so, add the host IP address to the API policy of the fabric. If the host is not allowed access to the fabric, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy.
SEC-1202 Severity 95 INFO SEC-1202 Message , [SEC-1202], ,, INFO, , Security violation: Unauthorized access from MS device node name , device port name . Probable Cause Indicates a management server (MS) security violation was reported. The unauthorized device specified in the message attempted to establish a connection. Recommended Action Check the MS server policy and verify that the connection is allowed.
95 SEC-1253 Probable Cause Indicates the security database conversion failed because of invalid values. The reason is specified in the text message variable and a faulty value is printed in the value variable. Recommended Action Retry the failed security command. Severity If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
SEC-1302 95 SEC-1302 Message , [SEC-1302], ,, INFO, , This switch does not have all the required PKI objects correctly installed. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database.
95 SEC-1306 Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify the fabric is still consistent. All the switches should be in the ready state.
SEC-1309 Severity 95 INFO SEC-1309 Message , [SEC-1309], ,, INFO, , Waiting for RCS transaction to complete: secs. Probable Cause Indicates that Secure Fabric OS is still waiting for the reliable commit service (RCS) transaction to complete. Recommended Action Verify if there are any RCS or RTWR errors. If not, the transaction is still in progress.
95 SEC-1313 Probable Cause Indicates the passwdCfg parameters changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1313 Message , [SEC-1313], ,, INFO, , The passwdcfg parameters were set to default values.
SEC-1316 95 SEC-1316 Message , [SEC-1316], ,, WARNING, , policy is conflicting with domain . Probable Cause Indicates the newly added switches to the fabric, as specified by Domain Number, have a conflicting policy with the local switch. Recommended Action Check the conflicting policy and make the new swithces and the local switch policies the same.
95 SEC-1320 SEC-1320 Message , [SEC-1320], ,, WARNING, , Non-acl domain tries to join a fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric with a strict fabric-wide policy. Recommended Action No action is required. The domain is denied by disallowing all its E_ports from connecting to the fabric.
SEC-1324 Recommended Action Severity 95 Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-1324 Message , [SEC-1324], ,, INFO, , Fabric transaction failure. RCS error: Probable Cause Indicates the reliable commit service (RCS) transaction failed with the specified reason code.
95 SEC-1328 Probable Cause Indicates the policy is conflicting with the domain. Recommended Action No action is required. The domain is denied by disallowing all its E_ports connected to the fabric. If the domain should be allowed to merge with the fabric, then resolve the issue by making the conflicting policies the same. Severity WARNING SEC-1328 Message , [SEC-1328], ,, ERROR, , Attempt to enable secure mode failed. Reason: .
SEC-1331 95 SEC-1331 Message , [SEC-1331], ,, ERROR, , Attempt to enable secure mode failed. Reason: . Probable Cause Indicates the secModeEnable command failed on the fabric because default IP Filter policies are not active on the switch, or an active transaction exists on IP Filter policies. Recommended Action Verify the security event was planned.
95 SEC-3005 Recommended Action Severity No action is required. INFO SEC-3005 Message , [SEC-3005], , INFO, , Event: , Status: success, Info: Added member(s) to policy . Probable Cause Indicates new members have been added to a security policy. If you use a wildcard (for example, an asterisk) in adding members to a policy, the audit report displays the wildcard in the event info field.
SEC-3037 95 SEC-3037 Message , [SEC-3037], , INFO, SECURITY, , Event: ipfilter, Status: success, Info: ipfilter policy activated. Probable Cause Indicates that that the specified IP filter policy has been activated. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required.
95 SEC-3051 Recommended Action Severity Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3051 Message , [SEC-3051], , INFO, SECURITY, , The license key is . Probable Cause Indicates that a license key is added or removed. Recommended Action No action is required.
SEC-3064 Recommended Action Severity 95 No action is required. INFO SEC-3064 Message , [SEC-3064], , INFO, SECURITY, , Permission to the RBAC class(es) is changed for the role . Probable Cause Indicates the permission to the RBAC class is changed for the role name. Recommended Action No action is required.
95 SEC-4001 Recommended Action Severity Invalid cipher list input, therefore reverted to previous cipher list. WARNING SEC-4001 Message , [SEC-4001], , AUDIT, INFO, SECURITY, , Client logged in . Probable Cause Indicates the client has logged in. Recommended Action No action is required.
Chapter SFLOW System Messages 96 SFLO-1001 Message , [SFLO-1001], ,, INFO, , sFlow is globally. Probable Cause Indicates that the sFlow is enabled or disabled globally. Recommended Action No action is required. Severity INFO SFLO-1002 Message , [SFLO-1002], ,, INFO, , sFlow is for port . Probable Cause Indicates that the sFlow is enabled or disabled for a particular port.
96 SFLO-1005 Recommended Action Severity No action is required. INFO SFLO-1005 Message , [SFLO-1005], ,, INFO, , sFlow sampling rate on port is changed to . Probable Cause Indicates that the sampling rate has changed on the port. Recommended Action No action is required. Severity INFO SFLO-1006 Message , [SFLO-1006], ,, INFO, , sFlow polling interval on port is changed to .
SFLO-1008 Recommended Action Severity 96 No action is required.
96 618 SFLO-1008 Fabric OS Message Reference 53-1002149-01
Chapter SNMP System Messages 97 SNMP-1001 Message , [SNMP-1001], ,, ERROR, , SNMP service is not available . Probable Cause Indicates the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Action Verify the IP address for the Ethernet and Fibre Channel interface is set correctly.
97 SNMP-1004 SNMP-1004 Message , [SNMP-1004], , FFDC, ERROR, CFG, , Incorrect SNMP configuration. Probable Cause Indicates the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Action Change the SNMP configuration back to the default.
SNMP-1008 Severity 97 INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Action Execute the nsshow command to view the current device status. Severity INFO SNMP-1009 Message , [SNMP-1009], ,, INFO, CFG, , Port traps are on port .
97 622 SNMP-1009 Fabric OS Message Reference 53-1002149-01
Chapter SPC System Messages 98 SPC-1001 Message , [SPC-1001], ,, INFO, , S, Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled on an encryption engine. Recommended Action No action is required. Severity INFO SPC-1002 Message , [SPC-1002], ,, INFO, , S, Cryptographic operation disabled.
98 SPC-2001 SPC-2001 Message , [SPC-2001], ,, ERROR, , S, : Crypto error asserted by Vader/OB1 0x. Probable Cause Indicates the Crypto error is asserted by FPGA. Recommended Action No action is required.
SPC-2005 Severity 98 ERROR SPC-2005 Message , [SPC-2005], ,, INFO, , S, : FPGA firmware download success: 0x. Probable Cause Indicates the FPGA download was successful. Recommended Action No action is required.
98 SPC-2009 Severity INFO SPC-2009 Message , [SPC-2009], ,, CRITICAL, , S, : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended Action EE is zeroized. Run the initEE and regEE commands.
SPC-2013 Severity 98 INFO SPC-2013 Message , [SPC-2013], ,, WARNING, , S, : Oscillator Failure Detected. Probable Cause Indicates hardware failure. Recommended Action Shelf life of the system may be reduced. Contact Vendor for further instructions.
98 SPC-2042 Severity ERROR SPC-2042 Message , [SPC-2042], ,, WARNING, , S, : Alloc msg - no free sbmsgs! Probable Cause Indicates no free message buffer in free pool. Recommended Action No action is required.
SPC-3002 Recommended Action Severity 98 For opaque key vaults such as RKM, recover the missing Master Key to current or alternate position. ERROR SPC-3002 Message , [SPC-3002], ,, ERROR, , S, : No input KEK for DEK rewrap, DEK: , KEK: .
98 SPC-3005 SPC-3005 Message Probable Cause , [SPC-3005], ,, ERROR, , S, :DEK inject error: , DEK: .
SPC-3008 • • • • Recommended Action Severity 98 14 - Creation not allowed: primary KEK generation is in progress 31 - DEK could not be wrapped 73 - Invalid KEK format other - Internal error For status code 14, complete primary KEK generation; otherwise, contact technical support. ERROR SPC-3008 Message , [SPC-3008], ,, INFO, , S, : SP crypto got READY notification.
98 SPC-3011 SPC-3011 Message , [SPC-3011], ,, ERROR, , S, : Persistent data storage error: , KEK: . Probable Cause Indicates an attempt to store Crypto Module internal data using the Secret Encryption Key failed most likely, the EE has been zeroized or tampered with.
SPC-3015 Recommended Action Severity 98 Contact technical support. ERROR SPC-3015 Message , [SPC-3015], ,, ERROR, , S, : RSA pairwise key generation test failure. Probable Cause Indicates the Crypto Module could not generate its internal key pair. Recommended Action Contact technical support.
98 634 SPC-3015 Fabric OS Message Reference 53-1002149-01
Chapter SPM System Messages 99 SPM-1001 Message , [SPM-1001], ,, ERROR, , Init fails: . Probable Cause Indicates the SPM has failed to initialize. Recommended Action Check the system resources and restart the switch. Severity ERROR SPM-1002 Message , [SPM-1002], ,, WARNING, , Generic SPM Warning: . Probable Cause Indiactes an SPM warning based on the reason displayed.
99 SPM-1005 Recommended Action Severity No action is required. INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause Indicates encryption engine (EE) control slot configuration. Recommended Action No action is required. Severity INFO SPM-1006 Message , [SPM-1006], ,, INFO, , Registered Certificate of type .
SPM-1009 Recommended Action Severity 99 No action is required. INFO SPM-1009 Message , [SPM-1009], ,, ERROR, , Certificate is missing. Probable Cause Indicates that a certificate is missing. Recommended Action Run the cryptocfg --initnode command. Severity ERROR SPM-1010 Message , [SPM-1010], ,, ERROR, , Key Vault Certificate is missing.
99 SPM-1013 Recommended Action Severity No action is required. INFO SPM-1013 Message , [SPM-1013], ,, ERROR, , Security database is out of sync. Probable Cause Indicates a failure to distribute security database. Recommended Action Use cryptocfg --sync -securitydb to manually sync security db.
SPM-3001 Probable Cause Indicates a failure to distribute security database. Recommended Action Use the cryptocfg --sync -securitydb command to manually sync security db. Severity 99 WARNING SPM-3001 Message , [SPM-3001], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Node initialized. Probable Cause Indicates a node was initialized. Recommended Action No action is required.
99 SPM-3005 Recommended Action Severity No action is required. INFO SPM-3005 Message , [SPM-3005], ,, INFO, SECURITY, ,Event: cryptocfg Status: success, Info: EE in slot disabled. Probable Cause Indicates an encryption engine was disabled. Recommended Action No action is required.
SPM-3009 Recommended Action Severity 99 No action is required. INFO SPM-3009 Message , [SPM-3009], ,, INFO, SECURITY, ,Event: cryptocfg Status: success, Info: DH response accepted. Probable Cause Indicates a DH challenge was accepted. Recommended Action No action is required. Severity INFO SPM-3010 Message , [SPM-3010], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: EE in slot zeroized.
99 SPM-3013 Recommended Action Severity No action is required. INFO SPM-3013 Message , [SPM-3013], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: Key vault with certificate label \"\" deregistered. Probable Cause Indicates a key vault was de-registered. Recommended Action No action is required.
SPM-3017 Recommended Action Severity 99 No action is required. INFO SPM-3017 Message , [SPM-3017], ,, INFO, SECURITY, ,Event: cryptocfg Status: success, Info: Master key exported. Probable Cause Indicates a master key was exported. Recommended Action No action is required.
99 SPM-3021 Recommended Action Severity No action is required. INFO SPM-3021 Message , [SPM-3021], ,, INFO, SECURITY, ,Event: cryptocfg Status: success, Info: Authentication card registered. Certificate label: \"\" Certificate file: \"\". Probable Cause Indicates an authentication card was registered. Recommended Action No action is required.
SPM-3025 Recommended Action Severity 99 No action is required. INFO SPM-3025 Message , [SPM-3025], ,, INFO, SECURITY, , Event: cryptocfg Status: success, Info: File imported via usb: Source: Destination: . Probable Cause Indicates a file was imported through the USB device. Recommended Action No action is required.
99 SPM-3029 Recommended Action Severity No action is required. INFO SPM-3029 Message , [SPM-3029], ,, INFO, SECURITY, , Event: KeyVault Connection Status: , Info:KAC_Connect: . Probable Cause Indicates the status of key vault. Recommended Action No action is required.
Chapter SS System Messages 100 SS-1000 Message , [SS-1000], ,, INFO, , supportSave has uploaded support information to the host with IP address . Probable Cause Indicates the supportSave command was used to transfer support information to a remote location. Recommended Action No action is required.
100 SS-1003 SS-1003 Message , [SS-1003], ,, WARNING, , supportSave's operation to USB storage device aborted. Probable Cause Indicates a USB operation error has occurred during execution of the supportSave command. Complete error information cannot always be displayed in this message due to possible errors in subcommands being executed by the supportSave command. Recommended Action Run the usbstorage command to check the USB storage device settings.
SS-1007 Severity 100 WARNING SS-1007 Message , [SS-1007], ,, WARNING, , supportsave failed for the slot . Reason: No response from the blade in the corresponding slot for the given ss request. Probable Cause Indicates no reponse from the blade in the corresponding slot for the given supportsave request. Recommended Action Reboot the switch using the reboot command and then run the supportsave command.
100 SS-1009 650 Fabric OS Message Reference 53-1002149-01
Chapter SSMD System Messages 101 SSMD-1001 Message , [SSMD-1001], ,, ERROR, ,Failed to allocate memory: . Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Severity Restart or power cycle the switch.
101 SSMD-1005 Probable Cause Indicates that the specified function has failed to unlock the mutex (semaphore). Recommended Action Restart or power cycle the switch. Severity ERROR SSMD-1005 Message , [SSMD-1005], ,, ERROR, , SSM startup failed. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected, severe error during basic startup and initialization. Recommended Action Restart or power cycle the switch .
SSMD-1008 101 SSMD-1008 Message , [SSMD-1008], ,, ERROR, , Apptype TCAM Table full for Slot: chip:. Probable Cause Indicates that the Apptype TCAM table is full for the chip. Recommended Action Remove the unused Protocol-based VLAN classifiers and Layer 2 Extended ACLs.
101 SSMD-1203 Severity WARNING SSMD-1203 Message , [SSMD-1203], ,, WARNING, , QoS failed programming interface 0x PFC flow control. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface PFC flow control feature. Recommended Action Delete and reapply QoS 802.3x Pause flow control policy. Restart or power cycle the switch.
SSMD-1207 Recommended Action Severity 101 Delete and reapply the CEE Map CoS to PGID policy. Restart or power cycle the switch. WARNING SSMD-1207 Message , [SSMD-1207], ,, WARNING, , QoS failed programming interface 0x Default CoS. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Default CoS feature.
101 SSMD-1211 Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the CoS to Traffic Class mapping feature. Recommended Action Delete and reapply the QoS interface CoS to Traffic Class policy. Restart or power cycle the switch.
SSMD-1214 101 SSMD-1214 Message , [SSMD-1214], ,, WARNING, , QoS failed programming interface 0x CoS Tail Drop Threshold. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface CoS Tail Drop Threshold feature. Recommended Action Delete and reapply the QoS CoS Tail Drop Threshold policy. Restart or power cycle the switch.
101 SSMD-1300 Severity WARNING SSMD-1300 Message , [SSMD-1300], ,, INFO, , CEEMap is created with precedence . Probable Cause Indicates that a CEEMap is created. Recommended Action No action is required. Severity INFO SSMD-1301 Message , [SSMD-1301], ,, INFO, , CEEMap is deleted. Probable Cause Indicates that a CEEMap is deleted. Recommended Action No action is required.
SSMD-1304 101 SSMD-1304 Message , [SSMD-1304], ,, INFO, , CEEMap priority group is deleted. Probable Cause Indicates that priority Group has been deleted. Recommended Action No action is required. Severity INFO SSMD-1305 Message , [SSMD-1305], ,, INFO, , CEEMap priority group weight is changed from to .
101 SSMD-1308 SSMD-1308 Message , [SSMD-1308], ,, INFO, , access list is deleted. Probable Cause Indicates that Access List has been deleted. Recommended Action No action is required. Severity INFO SSMD-1309 Message , [SSMD-1309], ,, INFO, , access list rule sequence number is .
SSMD-1312 101 SSMD-1312 Message , [SSMD-1312], ,, INFO, , assigned to interface . Probable Cause Indicates that user profile Map is assigned to an interface. Recommended Action No action is required. Severity INFO SSMD-1313 Message , [SSMD-1313], ,, INFO, , removed from interface .
101 SSMD-1316 SSMD-1316 Message , [SSMD-1316], ,, INFO, , CEEMap is reset to default configuration. Probable Cause Indicates that the CEE Map is reset to default because of the no cee-map name command. Recommended Action No action is required. Severity INFO SSMD-1317 Message , [SSMD-1317], ,, INFO, , ACL is being configured on interface . This operation could take a long time.
Chapter SULB System Messages 102 SULB-1001 Message , [SULB-1001], , WARNING, , Firmwaredownload command has started. Probable Cause Indicates the firmwareDownload command has been started. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption.
102 SULB-1004 SULB-1004 Message , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Probable Cause Indicates the FirmwareCommit command is executed. Recommended Action No action is required. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1005 Message , [SULB-1005], ,, INFO, , Current Active CP is preparing to failover.
SULB-1008 102 SULB-1008 Message , [SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Probable Cause Indicates the standby CP has rebooted successfully. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Severity Run the firmwareDownloadStatus command for more information.
102 SULB-1009 TABLE 7 666 Status messages and status codes (Continued) Status message Status code “firmwareCommit operation failed due to IPC error.” 0x55 "Unable to check the firmware version on Standby CP due to IPC error." 0x56 “Unable to restore the original firmware due to Standby CP timeout.” 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error.
SULB-1009 TABLE 7 Status messages and status codes (Continued) Status message Status code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 “There was an unexpected reboot during firmwareDownload. The command is aborted.
102 SULB-1009 TABLE 7 Status messages and status codes (Continued) Status message Status code “firmwareRestore is entered. System will reboot and a firmwareCommit operation will start upon boot up.” 0xa8 "Switch is relocating the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab “Blade failed to reboot with the original image. firmwareRestore command failed.
SULB-1009 TABLE 8 102 Error messages and error codes (Continued) Error message Error code "Our of disk space." 0x24 “Primary filesystem is inconsistent. Run firmwareRestore to restore the original firmware, or contact your service provider for recovery.” 0x25 "The post-install script failed." 0x26 "Unexpected reboot." 0x27 "Primary kernel partition is inconsistent. Please contact your service provider for recovery." 0x28 "The pre-install script failed.
102 SULB-1009 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server.
SULB-1010 102 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
102 SULB-1018 Recommended Action Severity Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. ERROR SULB-1018 Message , [SULB-1018], , ERROR, , Firmwaredownload timed out in slot .
SULB-1022 102 SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in slot has rebooted successfully with new firmware. Probable Cause Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step in the firmwareDownload process. Recommended Action Run the firmwareDownloadStatus command to monitor the firmwareDownload progress.
102 SULB-1025 SULB-1025 Message , [SULB-1025], ,, WARNING, , The blade in slot will reboot with the new firmware. Probable Cause Indicates new firmware has been downloaded to the specified AP blade and that the AP blade will reboot to activate it. Recommended Action Wait for the blade to reboot.
SULB-1032 Recommended Action Severity 102 Wait for the operation to complete. WARNING SULB-1032 Message , [SULB-1032], , WARNING, , Relocating an internal firmware image on the CP. Probable Cause Indicates the switch has started a firmware download to the co-CPU. Recommended Action Wait for the operation to complete.
102 SULB-1036 Probable Cause Indicates an error has occurred during the relocation of the internal image. The error may be caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Action Reset the switch. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider.
SULB-1039 102 SULB-1039 Message , [SULB-1039], , INFO, , CP has completed relocating the internal firmware image. Probable Cause Indicates that the firmwareDownload command process has been completed normally on the CP. Recommended Action Run the firmwareShow command to verify the firmware versions.
102 SULB-1043 Recommended Action Severity No action is required. The firmwareActivate command has completed as expected. Run the firmwareShow command to verify the firmware versions. INFO SULB-1043 Message , [SULB-1043], , INFO, , FirmwareActivation command failed. . Probable Cause Indicates the firmwareActivate command failed. The error string indicates why it failed.
Chapter SWCH System Messages 103 SWCH-1001 Message , [SWCH-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates the switch is enabled before it is ready. Recommended Action If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
103 SWCH-1004 SWCH-1004 Message , [SWCH-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = . Probable Cause Indicates a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command.
SWCH-1008 Recommended Action 103 Based on the disable reason displayed, proper corrective action may to be required to restore the port. If the disable reason is due to insufficient frame buffers, reduce the distance or speed settings for the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port group must be disabled to make more buffers available for the link. Refer to the Fabric OS Administrator’s Guide for more information about buffers.
103 SWCH-1011 Severity WARNING SWCH-1011 Message , [SWCH-1011], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Trunk Area functionality. (active ver = , Trunk Area enabled on switch = <'1' if Trunk Area ports exist; Otherwise '0'>). Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled.
SWCH-1015 Recommended Action Severity 103 No action is required. INFO SWCH-1015 Message , [SWCH-1015], ,, WARNING, , . Probable Cause Indicates that an internal problem has been detected by the software. This is usually an internal Fabric OS problem or due to file corruption. Recommended Action Restart or power cycle the switch Severity If the message persists, run the firmwareDownload command to update the firmware.
103 SWCH-1018 SWCH-1018 Message , [SWCH-1018], ,, INFO, , Device flogis to port , Static persistent PID set, Requested area user bound to another port. Reject FLOGI. Probable Cause Indicates WWN-PID and PortAddress binding collision. Recommended Action The Peristent PID is set on device and requested area cannot be assigned as its user is bound to a different port.
SWCH-1022 Recommended Action Severity 103 Load a firmware version on the standby CP that supports dynamic area on default switch, using the firmwareDownload command. WARNING SWCH-1022 Message , [SWCH-1022], ,, WARNING, , Port: have been disabled due to port address conflict while enabling FMS mode. Probable Cause Indicates the switch has ports with FMS reserved areas (0xFE or 0xFF) which are not supported in FMS mode.
103 SWCH-1022 686 Fabric OS Message Reference 53-1002149-01
Chapter SYSC System Messages 104 SYSC-1001 Message , [SYSC-1001], , FFDC, CRITICAL, , Failed to run :. Probable Cause Indicates that during the boot sequence, one of the programs does not run on the system. Recommended Action If the message is reported during a restart after new firmware has been loaded, try reloading the firmware using the firmwareDownload command.
104 SYSC-1004 It could also indicate that the current option number could not be read from the chassis option storage device (the world wide name (WWN) card). This message occurs only on the Brocade 24000 and 48000. Recommended Action Severity As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware.
Chapter SYSM System Messages 105 SYSM-1001 Message , [SYSM-1001], , FFDC, CRITICAL, , No memory. Probable Cause Indicates the switch has run out of system memory. Recommended Action Run the memShow command to view the switch memory usage. Restart or power cycle the switch. Run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
105 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Action Verify that the world wide name (WWN) card is present and operational and that the affected control processor (CP) is properly seated in its slot.
Chapter TAPE System Messages 106 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended Action No action is required.
106 TAPE-1001 692 Fabric OS Message Reference 53-1002149-01
Chapter TRCE System Messages 107 TRCE-1001 Message Probable Cause , [TRCE-1001], ,, WARNING, , Trace dump available< optional slot indicating on which slot the dump occurs >! (reason: ) Indicates that trace dump files have been generated on the switch or the indicated slot.
107 TRCE-1004 Probable Cause Indicates that a trace dump has been created on the switch or the indicated slot but is not automatically transferred from the switch due to an FTP error, such as a wrong FTP address, FTP site down, or network down. Recommended Action If the message persists, run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
TRCE-1007 107 TRCE-1007 Message , [TRCE-1007], ,, INFO, , Notification of this CP has failed. Parameters temporarily out of sync with other CP. Probable Cause Indicates that the active CP is unable to alert the standby CP of a change in trace status. This message is only applicable to the Brocade 24000, and 48000. Recommended Action This message is often transitory. Wait for a few minutes and retry the command.
107 TRCE-1011 Probable Cause Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace capability within the switch is unaffected. The traced facility is normally restarted automatically by the system after a brief delay. Recommended Action If the message persists, restart the CP (dual-CP system) or restart the switch.
Chapter TRCK System Messages 108 TRCK-1001 Message , [TRCK-1001], ,, INFO, , Successful login by user . Probable Cause Indicates the track change feature has recorded a successful login. Recommended Action No action is required. Severity INFO TRCK-1002 Message , [TRCK-1002], ,, INFO, , Unsuccessful login by user after overall login failure attempts.
108 TRCK-1004 TRCK-1004 Message , [TRCK-1004], ,, INFO, , Config file change from task:. Probable Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload command. This message is not generated for a configUpload command.
Chapter TS System Messages 109 TS-1001 Message Probable Cause , [TS-1001], ,, WARNING, , NTP Query failed: . Indicates a network time protocol (NTP) query to the configured external clock server failed. Local clock time on the principal or primary fabric configuration server (FCS) switch is used for fabric synchronization. This might be logged during temporary operational issues such as IP network connection issues to the external clock server.
109 TS-1006 TS-1006 Message Probable Cause , [TS-1006], ,, INFO, , . Indicates a time service event is occurring or has failed. The message might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits.
Chapter UCST System Messages 110 UCST-1003 Message , [UCST-1003], ,, INFO, , Duplicate Path to Domain , Output Port = , PDB pointer = 0x Probable Cause Indicates the duplicate paths were reported to the specified domain from the specified output port. The path database (PDB) pointer is the address of the path database and provides debugging information. Recommended Action No action is required.
110 UCST-1021 UCST-1021 Message , [UCST-1021], ,, INFO, CFG, , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required. Severity INFO UCST-1022 Message , [UCST-1022], ,, INFO, CFG, , In-order delivery option has been disabled.
UCST-1025 110 UCST-1025 Message , [UCST-1025], ,, INFO, CFG, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required.
110 UCST-1027 704 Fabric OS Message Reference 53-1002149-01
Chapter UPTH System Messages 111 UPTH-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list. Probable Cause Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended Action No action is required. This will end the current SPF computation.
111 UPTH-1002 706 Fabric OS Message Reference 53-1002149-01
Chapter VS System Messages 112 VS-1001 Message , [VS-1001], ,, INFO, , No virtual PWWN assignment for the device , port or (AG port )! Probable Cause Indicates the device tried to login with virtual PWWN feature enabled but no mapping for the device, port or AG port. Recommended Action Map the device, port or AG port using the vpwwn command. Ignore this message if Virtual PWWN not required.
112 VS-1004 VS-1004 Message , [VS-1004], ,, INFO, , !could not find Virtual WWN config file for the switch! Probable Cause Indicates the virtual WWN feature has been enabled for the first time on the switch or the configuration file got accidently removed or corrupted. Recommended Action Creating new default configuration file. If you want to download any of your earlier configuration for virtual WWN feature, then use configdownload command.
VS-1008 112 VS-1008 Message , [VS-1008], ,, INFO, , Virtualization services failed to create timer. Probable Cause Indicates failure in vsd daemon start up. Recommended Action Reboot the system.
112 VS-1008 710 Fabric OS Message Reference 53-1002149-01
Chapter WEBD System Messages 113 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL certificate file is either invalid or absent. Recommended Action Install a valid key file.
113 WEBD-1006 Recommended Action Severity No action is required. WARNING WEBD-1006 Message , [WEBD-1006], ,, INFO, , HTTP server and weblinker restarted due to logfile truncation. Probable Cause Indicates the size of the HTTP log file exceeded the maximum limit. Recommended Action No action is required.
Chapter XTUN System Messages 114 XTUN-1000 Message , [XTUN-1000], ,, ERROR, , FCIP Tunnel Missed Data frame:I/T/L://. Probable Cause Indicates a missed frame with one or more FCP data information units during a SCSI write or read operation. Recommended Action If there was an unexpected job failure associated with this event, contact your customer support for assistance.
114 XTUN-1003 XTUN-1003 Message , [XTUN-1003], ,, ERROR, , FCIP Tunnel Message Transmission failed:I/T/L/E:///. Probable Cause Indicates a message transmission failure. Recommended Action If there was an unexpected job failure associated with this event, contact your customer support for assistance.
XTUN-1997 Severity 114 INFO XTUN-1997 Message , [XTUN-1997], ,, WARNING, , FTRACE buffer on slot dp has been triggered. Probable Cause Indicates that a programmed trigger event has been detected. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance.
114 XTUN-2001 Severity INFO XTUN-2001 Message , [XTUN-2001], ,, ERROR, , FCIP Tunnel DOWN . Probable Cause Indicates that the specified tunnel has gone down. Recommended Action If the tunnel has not been administratively disabled or deleted, a possible network error or disruption has occurred.
XTUN-2005 Severity 114 INFO XTUN-2005 Message , [XTUN-2005], ,, ERROR, , FCIP Tunnel Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. This applies to the data classes only. If the f-class goes down, the tunnel itself is marked as down.
114 XTUN-2009 Severity INFO XTUN-2009 Message , [XTUN-2009], ,, INFO, , IPsec: . Probable Cause Indicates that the status of an IPsec Security Association has changed. Recommended Action No action is required. Severity INFO XTUN-2010 Message , [XTUN-2010], ,, INFO, , SPD: . Probable Cause Indicates that the status of an SPD entry has changed. Recommended Action No action is required.
XTUN-2021 114 XTUN-2021 Message , [XTUN-2021], ,, INFO, , FCIP Tunnel Circuit DELETED (). Probable Cause Indicates that the specified circuit has been administratively deleted. Recommended Action No action is required. Severity INFO XTUN-2022 Message , [XTUN-2022], ,, INFO, , FCIP Tunnel MODIFIED ().
114 XTUN-2025 XTUN-2025 Message , [XTUN-2025], ,, INFO, , FCIP Tunnel Circuit MODATTR (). Probable Cause Indicates that the attribute is modified. In most cases, the attribute value is modified within the specified circuit. Recommended Action No action is required.
Chapter ZEUS System Messages 115 ZEUS-1001 Message , [ZEUS-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between peer ports. Recommended Action Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have deteriorated and the Fibre Channel cable is faulty.
115 ZEUS-1004 ZEUS-1004 Message , [ZEUS-1004], , , ERROR, , S,C: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x. Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Action Restart the system at the next maintenance window. If the problem persists, replace the blade.
ZEUS-1016 Severity 115 WARNING Fabric OS Message Reference 53-1002149-01 723
115 ZEUS-1016 724 Fabric OS Message Reference 53-1002149-01
Chapter ZOLB System Messages 116 ZOLB-1001 Message , [ZOLB-1001], ,, ERROR, , ZONELIB Probable Cause Indicates there was an internal timeout on the inter process communication (IPC) between the name server (NS) and the zoning modules. This usually indicates that the system was busy. Recommended Action This message generates core dump files of the related modules (zoned, nsd, rcsd).
116 ZOLB-1001 726 Fabric OS Message Reference 53-1002149-01
Chapter ZONE System Messages 117 ZONE-1002 Message , [ZONE-1002], ,, WARNING, , WWN zoneTypeCheck or zoneGroupCheck warning() at port(). Probable Cause Indicates a zone filter or zone group check failure occurred. The frame filter logic reported a failure when creating or adding zone groups during port login (PLOGI) trap processing.
117 ZONE-1005 In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or alias members are defined using exclusively or using WWNs exclusively: that is, using one method or the other to define all objects in the zoning database. If the devices on the port are defined by a mixture of port IDs and WWNs, the zone enforcement is session based.
ZONE-1007 117 ZONE-1007 Message , [ZONE-1007], ,, INFO, , Ioctl() in () at port () returns code () and reason string (). Probable Cause Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from which the failure is reported is listed as part of the error message.
117 ZONE-1013 Recommended Action Severity Check the device connetion. WARNING ZONE-1013 Message , [ZONE-1013], ,, WARNING, , Quick Loop not supported. Probable Cause Indicates the QuickLoop feature is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Action Edit the zone database to remove the QuickLoop zoning definition in the effective configuration.
ZONE-1018 117 Probable Cause Indicates the fabric assist (FA) zoning configuration has more than one initiator. The probable cause is incorrect entries in the FA zoning configuration. Recommended Action Edit the zone database to ensure that only one initiator is set for each FA zone configuration. Severity ERROR ZONE-1018 Message Probable Cause , [ZONE-1018], ,, ERROR, , Incorrect zoning enforcement type() at port().
117 ZONE-1022 ZONE-1022 Message , [ZONE-1022], ,, INFO, , The effective configuration has changed to . Probable Cause Indicates the effective zone configuration has changed to the name displayed. Recommended Action Verify this zone configuration change was done on purpose. If the new effective zone configuration is correct, no action is necessary.
ZONE-1027 117 ZONE-1027 Message Probable Cause , [ZONE-1027], ,, INFO, , Zoning transaction aborted . . Indicates the zoning transaction was aborted due to a variety of potential errors. The error reason variable can be one of the following: • • • • • • • • Recommended Action Severity Zone Merge Received: The fabric is in the process of merging two zone databases.
117 ZONE-1030 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030], ,, WARNING, , Converting the zone db for PID format change failed. Probable Cause Indicates the current zone database could not be converted to reflect the PID format change. Most likely this is caused by the size of the zone database.
ZONE-1034 117 Probable Cause Indicates the specified domain has the lowest memory available for the zone database in the fabric. The zone database must be smaller than the memory available on this domain. Recommended Action Reduce the size of the zone database and retry the operation. Severity ERROR ZONE-1034 Message , [ZONE-1034], ,, INFO, , A new zone database file is created. Probable Cause Indicates that a new zone database was created.
117 ZONE-1037 ZONE-1037 Message , [ZONE-1037], ,, ERROR, , Unable to examine : error message . Probable Cause Indicates the Fabric OS cannot examine the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation.
ZONE-1041 Severity 117 INFO ZONE-1041 Message , [ZONE-1041], ,, WARNING, , Unstable link detected during merge at port (). Probable Cause Indicates a possible unstable link or faulty cable. Recommended Action Check the SFP and cable at the specified port and verify that they are not faulty. Replace the SFP and cable as necessary.
117 ZONE-1045 ZONE-1045 Message , [ZONE-1045], ,, INFO, , The Default Zone access mode is already set to No Access. Probable Cause Indicates that the Default Zone access mode is already set to No Access. Recommended Action No action is required. Severity INFO ZONE-1046 Message , [ZONE-1046], ,, INFO, , The Default Zone access mode is already set to All Access.
ZONE-1049 117 ZONE-1049 Message , [ZONE-1049], ,, ERROR, , ZONE AD-DefZone conflict detected while system initialization. Probable Cause Indicates that there is an AD-DefZone conflict. Recommended Action Check and resolve the default zone mismatch issue. Severity ERROR ZONE-1050 Message , [ZONE-1050], ,, INFO, , The Interop Safe Zoning mode is set to Enabled.
117 ZONE-1053 ZONE-1053 Message , [ZONE-1053], ,, INFO, , The Default Zone state is set to Disabled. Probable Cause Indicates the Interop Default Zone attribute state is disabled. Recommended Action Verify if the Interop Default Zone attribute state change was done on purpose. Severity INFO ZONE-1054 Message , [ZONE-1054], ,, WARNING, , DEFZONE ALLACCESS set with Frame Redirection zones.
ZONE-1057 117 ZONE-1057 Message , [ZONE-1057], ,, WARNING, , TI Zone has domain running pre FOS6.4.0 firmware. TI member (Domain , Index ) is not supported. Probable Cause Indicates that an unsupported port index(> 511) is present in the TI zone path. Recommended Action Remove the port index from the TI zone or the routing may not be setup correctly.
117 ZONE-1060 Probable Cause Indicates that only TI failover-disabled paths remain to reach the given domain causing non-TI and TI failover traffic disruption. Recommended Action Add or restore the non-TI ISLs and/or TI failover-enabled ISLs to the specified domain.
Section II Audit Log Messages This section provides the Audit messages, including: • AUDIT AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT AN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT AUTH System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT BLS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
744 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT AG System Messages 118 AG-1033 Message AUDIT, , [AG-1033], INFO, CFG, , , , F_Port to N_Port mapping has been updated for N_Port (). Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the configuration file has been updated. Recommended Action No action is required.
118 AG-1036 AG-1036 Message AUDIT, , [AG-1036], WARNING, CFG, , , , Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a Non-Brocade Fabric. Recommended Action No action is required.
Chapter AUDIT AN System Messages 119 AN-1003 Message AUDIT, , [AN-1003], WARNING, FABRIC, , , , Latency bottleneck on port /. pct. of secs. affected. Avg. time b/w transmits us. Avg.
119 AN-1006 Severity INFO AN-1006 Message AUDIT, , [AN-1006], INFO, FABRIC, , , , Bottleneck detection configuration is successfully changed. Probable Cause Indicates that the bottleneck detection configuration was changed by a user. Recommended Action No action is required.
AN-1013 Recommended Action Severity 119 The port is recovered. No action is required. WARNING AN-1013 Message AUDIT, , [AN-1013], WARNING, FABRIC, , , , Performed link reset to recover the port credits on slot port . Probable Cause Indicates a credit loss. Recommended Action The port is recovered. No action is required.
119 AN-1013 750 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT AUTH System Messages 120 AUTH-1045 Message AUDIT, , [AUTH-1045], ERROR, SECURITY, , , , Certificate not present in this switch in port . Probable Cause Indicates that the public key infrastructure (PKI) certificate is not installed in this switch. Recommended Action Check the certificate availability using the pkiShow command.
120 AUTH-3001 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type can be either authentication type, DH group type, Hash type or policy type. Recommended Action No action is required.
AUTH-3005 120 Probable Cause The specified E_Port was disabled because the neighboring switch rejected the authentication negotiation, and the local switch has a strict switch authentication policy. Recommended Action Correct the switch policy configuration on either of the switches using the authUtil command, and then enable the specified port using the portEnable command.
120 AUTH-3008 Probable Cause Indicates that the specified port was disabled due to receiving an authentication reject response from the connected switch/device. The error might indicate that an invalid entity attempted to connect to the switch. Recommended Action Check the connection port for a possible security attack. Check the shared secrets using the secAuthSecret command and reinitialize authentication using the portDisable and portEnable commands.
Chapter AUDIT BLS System Messages 121 BLS-1002 Message AUDIT, , [BLS-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec or IKE policy was added and the configuration file was updated. Recommended Action No action is required. Severity INFO BLS-1003 Message AUDIT, , [BLS-1003], INFO, CFG, , , , An IPsec/IKE policy was deleted.
121 BLS-1003 756 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT CEE CONFIG System Messages 122 CCFG-1002 Message AUDIT, , [CCFG-1002], INFO, CFG, , , , Started loading CEE system configuration. Probable Cause Indicates that the Converged Enhanced Ethernet (CEE) system configuration has started loading. Recommended Action No action is required.
122 CCFG-1013 758 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT CNM System Messages 123 CNM-3001 Message AUDIT, , [CNM-3001], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: encryption group \\ created. Probable Cause Indicates an encryption group was created. Recommended Action No action is required.
123 CNM-3004 CNM-3004 Message AUDIT, , [CNM-3004], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Membernode \\ ejected from encryption group. Probable Cause Indicates a membernode was ejected from an encryption group. Recommended Action No action is required.
CNM-3008 Severity 123 INFO CNM-3008 Message AUDIT, , [CNM-3008], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Routing mode of EE in slot set to . Probable Cause Indicates that the Encryption Engine (EE) routing mode was set. Recommended Action No action is required.
123 CNM-3012 Recommended Action Severity No action is required. INFO CNM-3012 Message AUDIT, , [CNM-3012], INFO, SECURITY, , , , Deleteing an EG with luns setup for encryption can lead to luns being disabled if Encryption Group name is not preserved (). Probable Cause Indicates that the Encryption Group (EG) was deleted, recreate EG with the same name if luns are setup for encryption.
Chapter AUDIT CONF System Messages 124 CONF-1000 Message AUDIT, , [CONF-1000], INFO, CFG, , , , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed successfully. The statement that follows, message string, is the description of the classes of configuration parameters that were downloaded.
124 CONF-1022 Severity INFO CONF-1022 Message AUDIT, , [CONF-1022], WARNING, CFG, , , , Downloading configuration without disabling the switch was unsuccessful. Probable Cause Indicates an attempt to download the configuration without disabling the switch was unsuccessful because there are one or more parameters that require the switch to be disabled.
Chapter AUDIT CVLM System Messages 125 CVLM-3001 Message AUDIT, , [CVLM-3001], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates that the failback mode was set. Recommended Action No action is required.
125 CVLM-3004 CVLM-3004 Message AUDIT, , [CVLM-3004], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Cluster member added to HA cluster . Probable Cause Indicates a HA cluster member was added to an HA cluster. Recommended Action No action is required.
CVLM-3008 Severity 125 INFO CVLM-3008 Message AUDIT, , [CVLM-3008], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Container \\ deleted. Probable Cause Indicates a cryptotarget container was deleted. Recommended Action No action is required.
125 CVLM-3012 Recommended Action Severity No action is required. INFO CVLM-3012 Message AUDIT, , [CVLM-3012], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Initiator \\ removed from crypto target container \\. Probable Cause Indicates an initiator was removed from a cryptotarget container. Recommended Action No action is required.
CVLM-3015 125 CVLM-3015 Message AUDIT, , [CVLM-3015], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Lun , attached through Initiator \\, removed from crypto target container \\. Probable Cause Indicates a LUN was removed from a cryptotarget container. Recommended Action No action is required.
125 CVLM-3019 Recommended Action Severity No action is required. INFO CVLM-3019 Message AUDIT, , [CVLM-3019], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Tape pool \\ modified. Probable Cause Indicates a tapepool was modified. Recommended Action No action is required.
CVLM-3022 125 CVLM-3022 Message AUDIT, , [CVLM-3022], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Resume rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable Cause Indicates a resume rekey was performed. Recommended Action No action is required.
125 CVLM-3026 Severity INFO CVLM-3026 Message AUDIT, , [CVLM-3026], INFO, SECURITY, , , , Event: cryptocfg Status: failed, Info: Decommission of device (container initiator , LUN ). Probable Cause Indicates that the decommission operation has failed for the device. Recommended Action Reissue the decommission command.
Chapter AUDIT ESS System Messages 126 ESS-1008 Message AUDIT, , [ESS-1008], INFO, FABRIC, , , , Fabric Name - configured (received from domain ). Probable Cause Indicates that the fabric name is configured or renamed. Recommended Action No action is required.
126 ESS-1010 774 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT FCIP System Messages 127 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended Action No action is required. Severity INFO FCIP-1003 Message AUDIT, , [FCIP-1003], INFO, CFG, , , , An IPsec/IKE policy was deleted.
127 FCIP-1003 776 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT FICU System Messages 128 FICU-1011 Message AUDIT, , [FICU-1011], INFO, CFG, , , , FMS mode has been enabled. Probable Cause Indicates that the Fibre Connectivity (FICON) Management server mode has been enabled. Recommended Action No action is required. Severity INFO FICU-1012 Message AUDIT, , [FICU-1012], INFO, CFG, , , , FMS mode has been disabled.
128 FICU-1021 Recommended Action Severity No action is required. INFO FICU-1021 Message AUDIT, , [FICU-1021], INFO, CFG, , , , Port Addrs (%s) have been UnBlocked by %s. Probable Cause Indicates the Fibre Connectivity (FICON) Management server has unblocked ports. Recommended Action No action is required.
Chapter AUDIT FW System Messages 129 FW-1202 Message AUDIT, , [FW-1202], WARNING, FW, , , , ,
129 FW-1404 FW-1404 Message AUDIT, , [FW-1404], WARNING, FW, , , ,
FW-3001 Recommended Action Severity 129 No action is required.
129 FW-3001 782 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT HTTP System Messages 130 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has been changed. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
130 HTTP-1003 784 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT IPAD System Messages 131 IPAD-1002 Message AUDIT, , [IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended Action No action is required.
131 IPAD-1002 786 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT MS System Messages 132 MS-1027 Message AUDIT, , [MS-1027], INFO, FABRIC, , , , Fabric Name - configured. Probable Cause Indicates that the fabric name is configured or renamed. Recommended Action This is an informational message and does not require any action. Severity INFO MS-1028 Message AUDIT, , [MS-1028], INFO, FABRIC, , , , Fabric Name - Cleared.
132 MS-1029 788 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT PMGR System Messages 133 PMGR-1001 Message AUDIT, , [PMGR-1001], INFO, LS, , , , Attempt to create switch succeeded. Probable Cause Indicates that the switch with the specified FID was successfully created. Recommended Action No action is required. Severity INFO PMGR-1003 Message AUDIT, , [PMGR-1003], INFO, LS, , , , Attempt to delete switch succeeded.
133 PMGR-1003 790 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT PORT System Messages 134 PORT-1006 Message AUDIT, , [PORT-1006], INFO, CFG, , , , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended Action No action is required.
134 PORT-1009 PORT-1009 Message AUDIT, , [PORT-1009], INFO, CFG, , , , GigE Port (ID: ) has been disabled. Probable Cause Indicates a GigE port has been disabled. Recommended Action No action is required.
Chapter AUDIT RAS System Messages 135 RAS-2001 Message AUDIT, , [RAS-2001], INFO,, , , , , Audit message log is enabled. Probable Cause Indicates that the audit message log is enabled. Recommended Action No action is required. Severity INFO RAS-2002 Message AUDIT, , [RAS-2002], INFO,, , , , Audit message log is disabled.
135 RAS-2003 794 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT SEC System Messages 136 SEC-1113 Message AUDIT, , [SEC-1113], WARNING, SECURITY, , , , [ license ] going to expire in days. Probable Cause Indicates the license period will expire soon. Recommended Action Get a new license for this feature.
136 SEC-3002 SEC-3002 Message Probable Cause AUDIT, , [SEC-3002], INFO, SECURITY, , , , Event: , Status: success, Info: . Indicates the specified security event has occurred. The Event Name can be one of the following: • • • • • Recommended Action Severity There has been an fabric configurations server (FCS) failover. A security policy has been activated. A security policy has been saved.
SEC-3005 136 SEC-3005 Message AUDIT, , [SEC-3005], INFO, SECURITY, , , , Event: , Status: success, Info: Added members to policy . Probable Cause Indicates new members have been added to the specified security policy. If you use a wildcard (for example, an asterisk) in adding members to a policy, the audit report displays the wildcard in the event info field.
136 SEC-3008 SEC-3008 Message AUDIT, , [SEC-3008], INFO, SECURITY, , , , Event: , Status: success, Info: FCS member moved from position to . Probable Cause Indicates the fabric configuration server (FCS) list has been modified. One of the members of the list has been moved to a new position in the list, as identified in the message. Recommended Action Verify the modification was planned.
SEC-3012 Recommended Action Severity 136 Verify that the security statistic was intentionally reset. If the security statistic were intentionally reset, no action is required. If the security statistic was not intentionally reset, take appropriate action as defined by your enterprise security policy.
136 SEC-3015 SEC-3015 Message AUDIT, , [SEC-3015], INFO, SECURITY, , , , Event: , Status: success, Info: Moved RADIUS server to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS or LDAP) server. Recommended Action Verify the RADIUS server position was intentionally changed.
SEC-3018 136 SEC-3018 Message AUDIT, , [SEC-3018], INFO, SECURITY, , , , Event: , Status: success, Info: Parameter [] changed from [] to []. Probable Cause Indicates the specified passwdCfg parameter is changed. Recommended Action Verify the passwdCfg parameter was intentionally changed. If the passwdCfg parameter was intentionally changed, no action is required.
136 SEC-3022 Recommended Action Severity Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3022 Message AUDIT, , [SEC-3022], INFO, SECURITY, , , , Event: , Status: success, Info: Successful logout by user [].
SEC-3025 136 SEC-3025 Message AUDIT, , [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home Context [], AD/VF list []. Probable Cause Indicates a new user account was created. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
136 SEC-3029 Recommended Action Severity Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3029 Message AUDIT, , [SEC-3029], INFO, SECURITY, , , , Event: , Status: success, Info: Backup user account \"\" recovered.
SEC-3032 136 SEC-3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database. Probable Cause Indicates the specified event has occurred to accept or reject a certain database. Recommended Action Verify the event was planned. If the event was planned, no action is required.
136 SEC-3036 Recommended Action Severity Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3036 Message AUDIT, , [SEC-3036], INFO, SECURITY, , , , Event: ipfilter, Status: failed, Info: Failed to save changes for ipfilter policies.
SEC-3039 136 SEC-3039 Message AUDIT, , [SEC-3039], INFO, SECURITY, , , , Event: Securty Violation, Status: failed, Info: Unauthorized host with IP address tries to establish connection using . Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message.
136 SEC-3047 Recommended Action Severity Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3047 Message AUDIT, , [SEC-3047], INFO, SECURITY, , , Info: RBAC permission for a CLI command: is failed.
SEC-3051 136 Probable Cause Indicates the specified sshutil operation was performed.. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3051 Message AUDIT, , [SEC-3051], INFO, SECURITY, , , , The license key is .
136 SEC-3064 Probable Cause Indicates a role name is copied from source role. Recommended Action No action is required. Severity INFO SEC-3064 Message AUDIT, , [SEC-3064], INFO, SECURITY, , , , Permission to the RBAC class(es) ‘’ is changed for the role ‘’. Probable Cause Indicates the permission to the RBAC class is changed for the role name. Recommended Action No action is required.
SEC-4001 Probable Cause Indicates the input cipher list is an invalid string. Recommended Action Invalid cipher list input, therefore reverted to previous cipher list. Severity 136 WARNING SEC-4001 Message AUDIT, , [SEC-4001], INFO, SECURITY, , , , Client logged in , , . Probable Cause Indicates the client has logged in. Recommended Action No action is required.
136 SEC-4001 812 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT SNMP System Messages 137 SNMP-1004 Message AUDIT, , [SNMP-1004], ERROR, CFG, , , , Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Action Reset the SNMP configuration to default.
137 SNMP-1009 SNMP-1009 Message AUDIT, , [SNMP-1009], INFO, CFG, , , , Port traps are on port . Probable Cause Indicates the blocked or unblocked status of the port. Recommended Action Execute the snmpTraps command to view the current status of the port.
Chapter AUDIT SPM System Messages 138 SPM-3001 Message AUDIT, , [SPM-3001], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Node initialized. Probable Cause Indicates a node was initialized. Recommended Action No action is required. Severity INFO SPM-3002 Message AUDIT, , [SPM-3002], INFO, SECURITY, , ,, Event: cryptocfg Status: success, Info: EE in slot initialized.
138 SPM-3005 Probable Cause Indicates an encryption engine was enabled. Recommended Action No action is required. Severity INFO SPM-3005 Message AUDIT, , [SPM-3005], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: EE in slot disabled. Probable Cause Indicates an encryption engine was disabled. Recommended Action No action is required.
SPM-3008 138 SPM-3008 Message AUDIT, , [SPM-3008], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended Action No action is required.
138 SPM-3012 SPM-3012 Message AUDIT, , [SPM-3012], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended Action No action is required.
SPM-3016 Severity 138 INFO SPM-3016 Message AUDIT, , [SPM-3016], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Master key generated. Probable Cause Indicates a master key was generated. Recommended Action No action is required. Severity INFO SPM-3017 Message AUDIT, , [SPM-3017], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Master key exported.
138 SPM-3020 Severity INFO SPM-3020 Message AUDIT, , [SPM-3020], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: System card with certificate label \"\" deregistered. Probable Cause Indicates a system card was deregistered. Recommended Action No action is required.
SPM-3024 Recommended Action Severity 138 No action is required. INFO SPM-3024 Message AUDIT, , [SPM-3024], INFO, SECURITY, , ,,Event: cryptocfg Status: success, Info: Quorum size set to . Probable Cause Indicates the quorum size was set. Recommended Action No action is required.
138 SPM-3028 Probable Cause Indicates a recovery card was registered. Recommended Action No action is required. Severity INFO SPM-3028 Message AUDIT, , [SPM-3028], INFO, SECURITY, , , , Event: SPM-EE state changed, Info: EE State: . Probable Cause Indicates an EE state has changed. Recommended Action No action is required.
Chapter AUDIT SULB System Messages 139 SULB-1001 Message AUDIT, , [SULB-1001], WARNING, FIRMWARE, , , , Firmwaredownload command has started. Probable Cause Indicates the firmwareDownload command has been started. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption.
139 SULB-1004 SULB-1004 Message AUDIT, , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Probable Cause Indicates the FirmwareCommit command is executed. Recommended Action No action is required. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed.
SULB-1009 TABLE 10 Status messages and status codes (Continued) Status message Status code “firmwareCommit operation failed due to IPC error.” 0x55 "Unable to check the firmware version on Standby CP due to IPC error." 0x56 “Unable to restore the original firmware due to Standby CP timeout.” 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error.
139 SULB-1009 TABLE 10 826 Status messages and status codes (Continued) Status message Status code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 “There was an unexpected reboot during firmwareDownload. The command is aborted.
SULB-1009 TABLE 10 139 Status messages and status codes (Continued) Status message Status code “firmwareRestore is entered. System will reboot and a firmwareCommit operation will start upon boot up.” 0xa8 "Switch is relocating the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab “Blade failed to reboot with the original image. firmwareRestore command failed.
139 SULB-1009 TABLE 11 Error messages and error codes (Continued) Error message Error code "Our of disk space." 0x24 “Primary filesystem is inconsistent. Run firmwareRestore to restore the original firmware, or contact your service provider for recovery.” 0x25 "The post-install script failed." 0x26 "Unexpected reboot." 0x27 "Primary kernel partition is inconsistent. Please contact your service provider for recovery." 0x28 "The pre-install script failed.
SULB-1009 139 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server.
139 SULB-1010 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
SULB-1020 Recommended Action Severity 139 Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider.
139 SULB-1024 Recommended Action Severity The firmwareCommit command will be started automatically after the blade boots up to repair the secondary partition. If at the end of firmwareCommit, the blade firmware version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider.
SULB-1031 Recommended Action Severity 139 The firmwareDownload command will continue after the switch has rebooted. Run the firmwareDownloadStatus command to monitor progress. If the problem persists, contact your switch service provider. WARNING SULB-1031 Message AUDIT, , [SULB-1031], WARNING, FIRMWARE, , , , The switch is relocating an internal firmware image.
139 SULB-1035 Recommended Action Severity Reboot the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. ERROR SULB-1035 Message AUDIT, , [SULB-1035], ERROR, FIRMWARE, , , , An error has occurred during relocation of the internal image.
SULB-1039 139 SULB-1039 Message AUDIT, , [SULB-1039], INFO, FIRMWARE, CP has completed relocating the internal firmware image. Probable Cause Indicates that the firmwareDownload command process has been completed normally on the CP. Recommended Action Run the firmwareShow command to verify the firmware versions.
139 SULB-1042 Recommended Action Severity 836 No action is required. The firmwareActivate command has completed as expected. Run the firmwareShow command to verify the firmware versions.
Chapter AUDIT SWCH System Messages 140 SWCH-1012 Message AUDIT, , [SWCH-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates that a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended Action No action is required.
140 SWCH-1014 838 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT UCST System Messages 141 UCST-1021 Message AUDIT, , [UCST-1021], INFO, CFG, , , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required.
141 UCST-1024 UCST-1024 Message AUDIT, , [UCST-1024], INFO, CFG, , , , Dynamic Load Sharing option has been disabled. Probable Cause Indicates the DLS option has been disabled for the switch. Recommended Action No action is required. Severity INFO UCST-1025 Message AUDIT, , [UCST-1025], INFO, CFG, , , , In-order delivery option has been enabled with Lossless-DLS option.
UCST-1027 Recommended Action Severity 141 No action is required.
141 UCST-1027 842 Fabric OS Message Reference 53-1002149-01
Chapter AUDIT ZONE System Messages 142 ZONE-3001 Message Probable Cause AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \"\". Indicates that a new zone object member or members have been added to the specified zone object set. The zone object type can be alias, zone member, zone or zone configuration.
142 ZONE-3004 Recommended Action Severity Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3004 Message Probable Cause AUDIT, , [ZONE-3004], INFO, ZONE, , , , Event: , Status: success, Info: \"\" removed from \"\".
ZONE-3007 142 ZONE-3007 Message AUDIT, , [ZONE-3007], INFO, ZONE, , , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been enabled. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
142 ZONE-3011 Severity INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged. Probable Cause Indicates the specified zone object has been expunged. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3015 142 An AD object may be an AD alias or AD member. The string “...” appears at the end of the AD object member list if the list was truncated in the message. Recommended Action Severity Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
142 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates the specified admin domain (AD) object has been deactivated. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3022 Severity 142 INFO ZONE-3022 Message AUDIT, , [ZONE-3022], INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration has been saved to flash. Recommended Action Verify the event was planned. If the event was planned, no action is required.
142 ZONE-3025 Recommended Action Severity 850 Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.