HP EVA Updating Product Software Guide (xcs10001000) (5697-2423, December 2012)

12. Click Browse to navigate to the controller software image file (created from the downloaded
.ISO image) (see “Required kits” (page 6)) and select the appropriate file (Table 9 (page
48)).
Table 9 Controller software
Select this file:For this array:
\HSV300\10001000\300_10001000.SSSEVA4400
\HSV400\10001000\400_10001000.SSSEVA6400
\HSV450\10001000\450_10001000.SSSEVA8400
13. Click Next Step to upload the appropriate controller software image file.
A second code load confirmation window opens.
Figure 19 Second code load confirmation window
Enter YES (all uppercase) and click Continue.
14. The Code Load Storage System — Page 5 window (Figure 20 (page 49)) opens. Read any
pre-update application notes before proceeding. Click Finish to proceed or Cancel to exit the
procedure.
48 Upgrading the Enterprise Virtual Array