HP P6000 Enterprise Virtual Array release notes (XCS 10001000) (5697-1819, March 2012)

Fixed an issue where back-end transport errors caused the controller software to fail a disk drive
unnecessarily.
Fixed an issue where the array would not log any events to indicate the back-end disk enclosures
were improperly cabled.
Fixed an issue where the I/O module firmware upgrade gets blocked when a disk enclosure
disappears and then remains blocked when the enclosure is accessible again.
Fixed a problem that, in rare circumstances, occurred when I/O to a disk volume failed and a
bad block replacement was not attempted. As a result, the controller could experience a stalled
state and execute a CSM Reset termination to clear the stalled state.
To eliminate unnecessary service actions, reporting of events 0D DE 95 06: A drive
enclosure I/O module is not communicating with the other I/O module and
09 CD C3 05: SCMI Fibre Channel port FAILED have been discontinued.
Fixed a rare controller restart that occurs when reading the link status from disk drives while
workloads are in progress.
Addressed several situations where drives could erroneously be reported as Single Port on Fibre
(SPOF), indicating it is only connected to one of the two device side I/O loops, and has lost
redundancy.
Fixed an issue where some drive check conditions were not being handled as transport errors,
resulting in drives being failed incorrectly.
Fixed an issue where background processing can be blocked and cause a CSM Reset termination
if a drive firmware SMART (Self Monitoring Analysis and Reporting) error is encountered while
waiting for a drive quiesce to complete or when accessing disk media.
Fixed an issue where the disk enclosure shutdown process would return a failure status even if
the shutdown operation succeeded.
Fixed an issue where some fields were missing or not completely populated in log events related
to disk enclosure link module status or firmware upgrades.
Fixed an issue where poorly seated back-end cables could result in too many dropped frame
(code 0x061d4709) and metadata error bit (e-bit) set (0x070e0015) events, flooding the logs.
Corrected an issue where the incorrect WWID entered from the operator control panel of an
EVA6400/8400 was accepted and stored with the secondary controller.
Fixed an issue where internal parity generation and checking resources were not configured
correctly.
Added event logging to output the current controller hardware revision and control and cache
memory configuration during boot.
Fixed event strings related to System Inoperative events.
Fixed an issue where the array logs a spontaneous power PC reset termination event instead of
the power loss event when power fails during a restart.
Fixed an issue where a controller host port could stop responding after a restart due to the improper
processing of brief, recovered link failures.
Fixed a controller restart that resulted from unexpected host mode sense requests.
Fixed a rare condition involving duplicate entries in a host port transaction buffer time and
organization queue. The problem appears to occur in all types of controllers and is not port
specific. A rare condition results, which may cause the item being aborted to be completed twice.
Fixed unnecessary failover/failback Unit Attention messages that are sent to hosts during controller
reboot. The messages affect hosts configured with host modes HP-UX, Sun Solaris, Windows
2003, and Windows 2008.
Fixes (XCS 10000000) 7