HP StorageWorks Enterprise Virtual Array 3000/5000 Release Notes (VCS 3.028) (5697-5385, December 2005)

Fault managemen
t and diagnostic enhancements
Improved handling of disk drives which disrupt device discovery, resulting in improved system
availability.
Fault management and diagnostics
WEBESmustbeinstalledtoensureproperalertsforyourEVAproducts.YoucanuseWEBESwithHP
ISEE remote service, or you can congure WEBES to send email notication only to a loc al account.
The email option is a lso available when you use WEBES with ISEE.
WEBES is a service tool that provides real-time diagnosis of hardware events ranging from single errors
(or faults) to multiple event correlation and complex analysis. It is designed to send notication only
when events require a ser vice action.
A Service Tools CD, containing WEBES and ISEE, is included with HP Command View EVA. HP
recommends that you also check the HP web site for updates. You can download the latest WEBES
kit from this location:
h
ttp://h18000.www1.hp.com/support/svctools
EVA remote support tools
As a no-char
ge option, HP will install ISEE remote service tool for any Enterprise Virtual Array under
warr anty or
service support. This tool enables EVA self-monitoring and diagnosis. ISEE can signicantly
reduce the
time required to isolate and correct p roblems. If desired, the tool can be con gured to
transmit s
tatus information directly to an HP service center for proactive problem resolution. Contact
your local HP Services department for details.
Subscribing to proactive updates
Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, rmware ,
and customer replaceable c omponents, proactively via email through HP Subscriber's Choice. Sign
up for Subscriber's Choice at the follow ing URL:
h
ttp://www.hp.com/go/myadvisory
Resolve
dissues
The following issues have been resolved in v3.028.
General issues
Resolved an issue where a large host data transfer a nd simultaneous SCSI reservation change
caused a low memory access controller restart.
Correctly manage a drive that could not be codeloaded because drive rmware is not available.
Corrected an EVA Perf issue to ensu re that performance data is reported for the proper virtual disk.
Provide improved logg ing by implementing new termination and controller event codes.
Improved virtual disk expansion process.
Adjusted time out values for data I/O and send/receive diagnostic commands to eliminate
failure of good disk drives.