HP StorageWorks Enterprise Virtual Array Online Firmware Upgrade Best Practices (5697-6388, January 2007)

2 Evaluating the SAN for an online
upgrade
Before performing an online upgrade, the SAN environment must be evaluated to determine system
timeouts, identify I/O patterns, and select the best time to perform the upgrade. This will help ensure the
success of the online upgrade.
Managing host I/O timeouts
The default values for host operating parameters such as LUN timeout and queue dep th are typically set
to values that ensure proper operation with the storage system. These values are appropriate for most
storage system operations, including online rmware upgrades. In general, host LUN timeouts of 60
seconds or m
ore are adequate to accommodate an online upgrade. In most situations it will not be
necessary
to alter these settings to perform an online rmware upgrade.
If any host
timeout values have been decr eased to less than 60 seconds, it will be necessary to reset
them to their original default value. The following section provide a summ ary of the steps and com m ands
involve d in checking and changing timeout values for each supported operating system. Refer to the
operating system documentation for more information.
NOTE:
All opera
ting systems are supported for online controller rmware upgrades when the following
guideli
nes are followed for both raw and le system devices.
Unless otherwise indicated, cluster testing has not yet been completed in combination with online
controller rmware upg rades. Cluster information will be added to this document when the testing is
complete.
Microsoft Windows
NOTE:
Ensure that MPIO is installed and both paths are active and have access to the array.
Boot devices are supported with online controller rmware upgrades.
Checking timeout values
The key timeout setting is in the registry at HKEY_LOCAL_MACHINE/SYSTEM/
CurrentControlSet/Services/Disk/TimeoutValue is set to 3c (60 seconds)
HP-U
X
CAUTION:
If Serviceguard is being used, the timeout value is 45 s econds.
HP StorageWorks Enterprise Virtual Array online rmware upgrade best practices
13