HP StorageWorks Enterprise Virtual Array Online Firmware Upgrade Best Practices (5697-6388, January 2007)
Test results
Light load testing
Light load testing revealed that all three applications reported no errors of any kind during the firmware
upgrade, while displaying moderate to s ignificant latency for the duration of the firmware upgrade. The
firmware upgrade lasted approximately six minutes, during which all three applications continued to
respondanddidnotcauseanyerrors.
While the firmware event did cause latencies that are unacc eptable for normal operation, the amount
of time the unacceptable values persisted is significantly less than the amo unt of time that a system
shutdown, firmware upgrade and system restart would take.
Microsoft Exchange 20 03 per formed adequately until the firmware upgrade. See Figure 10.Thelarge
spike in LoadSim latency corresponds to the firmware upgrade. Once the upgrade was complete, the
Exchange system returned to normal operation with an acceptable latency (95th percentile Loadsim score
of < 1000). The average seconds per disk write mirrors the latency spike in the LoadSim score, but also
returns to a normal level after the event completes.
Fi
gure 10 Light load on Exch ange 2003
30
Effect of online firmware upgrade on application resiliency