HP StorageWorks Enterprise Virtual Array Online Firmware Upgrade Best Practices (5697-6388, January 2007)
Heavy load te
sting
Heavy load testing produced very similar results to the light load testing. The latencies and delays during
the firmware upgrade event were significantly higher, however. Again, the applications reported no
errors of any kind during the firmware upgrade.
During the heavy load phase, two LoadSim client machines were necessary to drive the number of users.
The latency score for both servers reached a maximum of ~5000ms, d uring the firmware upgrade. See
Figure 15. This latency translated into queued messages on the Exchange server and in LoadSim. After
the firmware upgrade completed, however, the latency dropped back to normal and all queued messages
drained. The firmware upgrade lasted approximately six to ten minutes.
Fig
ure 15 Heavy load on Exchang e 2003
HP StorageWorks Enterprise Virtual Array online firmware upgrade best practices
35