HP StorageWorks Novell NetWare connectivity 4.0C for the 3000/5000 Enterprise Virtual Array Release Notes (5697-6590, March 2007)

Operating const
raints
You can nd info
rmation about operating constraints specictotheEVArmware and HP StorageWorks
Command View EVA in their respective release notes.
Storage System Scripting Utility for EVA
The latest version of the Storage System Scripting Utility (SSSU) is available on the following HP website:
h
ttp: //h18006.www1.hp.com/products/storage/software/cmdvieweva/index.html
From this website, click Software and Drivers.
Avoiding prob
lem situations
This section describes problems that m ay arise and their solutions.
Codeload usage
When a maximally congured system is running at maximum load, codeload functionality is not effective.
The system m ay time out before codeload is complete. HP recommends that you always perform VCS
upgrades at an off-peak time.
SSSU
Changing comments on a disk enclosure
Use Command View EVA to change comments on a disk enclosure. If you try to change a d isk enclosure
comment using SSSU, the following error message appears:
Error: Invalid Operation
Changing the name of a disk enclosure
Changing the name of a disk enclosure is not supported with SSSU or Command View EVA. If you try to
change a disk enclosure name using SSSU, the following error message appears:
Error: Inv
alid Operation
Using the required service pack with SSSU
Ensure that the required service pack is installed if you are using sssunlm.nlm on Novell NetWare;
otherwise, a critical failure occurs on the second run. See Table 1 on page 5 for a list of the required
Novell NetWare service packs.
6