HP StorageWorks EVA iSCSI Connectivity Option 3.0 Release Notes (5697-6148, October 2006)

Adatecode,inyyyy-mm format followed by another dot (.)
A reverse domain name
Optional colon (:) prefixed by a string
If only using ASCII characters (U+0000 to U+007F), the following characters are allowed:
ASCII dash character (’-’ = U+002d)
ASCII dot character (’. = U+002e)
ASCII colon character (’:’ = U+003a)
ASCII lower-case characters (’a’..’z = U+0061..U+007a)
ASCII digit characters (’0’..’9’ = U+0030..U+0039)
NOTE:
See section 3.2.6 of Request for Comments (RFC) 3720 (iSCSI) for a description of the iSCSI name
string profile. You can access RFC 3720 at: ftp://ftp.rfc-editor.org/in-notes/rfc3720.txt.
Workaround
Follow the correct iqn name syntax as described in section 3.2.6 of RFC 3720.
For Windows—In the initiator GUI, click Reset under Change in the General tab to reset the iqn name
to its original name that was created when you installed the initiator.
For LinuxEdit the InitiatorName setting in the /etc/initiatorname.iscsi file using the
correct syntax.
For Linux and Windows—Reinstalling the initiator creates a valid iqn name.
iSCSI initiator LUNs disappear after changing the initiator iqn name
The mpx100 maintains a database of targets, initiators and LUNs and the corresponding links between
them. Whenever Command View presents or unpresents a LUN to an iSCSI initiator, it updates the
mpx100’s database. When a new iqn name logs into the mpx100, it is considered a new initiator and
no LUNs are assigned to it. All LUN assignments to the old iqn are still maintained.
Workaround
Using Command View EVA, unpresent the LUN from the old initiator iqn and then present it to the
new initiator iqn name. Remove the old initiator from the mpx100 database with either the mpx100
Manager GUI or the CLI.
Windows iSCSI initiators must add Tcp1323Opts to registry
Timestamps help TCP measure round trip time (RTT) accurately to adjust retransmission timeouts. The
Timestamps option provides two timestamp fields of 4 bytes each in the TCP header: one to record the
time the initial transmission is sent and one to record the time on the remote host.
To enable timestamps, the Tcp1323Opts entry must be set to REG_DWORD = 2 under
HKLM\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters.
Installing the Windows iSCSI initiator from the HP StorageWorks iSCSI Connectivity Option for Enterprise
Virtual Array Windows software kit automatically adds this registry setting.
EVA iSCSI Connectivity Option 3.0