HP 30-1002201 Loop Switch CLI Reference Guide (5697-5675, May 2006)
30-10022-01 loop switch CLI reference guide 35
A Event Messages
The event messages for the 30-10022-01 switch are listed below. A message’s applicable severity
level, as defined below, is also provided.
These severity levels can be used to designate the minimum severity level of events to be logged in
the Event Log and at which to illuminate the switch’s Fault LED.
Severity Level Severity Description
1 EMERGENCY Immediate action required; system failing.
2 ALERT Unrecoverable condition reported; major event in progress.
3 CRITICAL Event failed with possible loss of integrity.
4 ERROR Condition failed; action required.
5* WARNING Failed event occurred; no action required.
6 NOTIFY Configuration error or abnormal event occurred; no action required.
7 INFO Event occurred; no action required.
Note: * indicates default switch setting.
Message
Number
Severity Description
1 NOTIFY Power-on self test passed.
2 ALERT An internal power-on self test failure has been detected. This indicates a
hardware problem in the unit. Contact technical support and report the following
information: the GPIO module <module name/number> is not functioning.
3 ALERT An internal power-on self test failure has been detected. This indicates a
hardware problem in the unit. Contact technical support and report the following
information: the serial port loopback failed on character <address>.
4 ALERT A test failure has occurred in a fibre-channel port. If this is reported at power-on,
it indicates a hardware problem in the unit. Contact technical support and report
the following information: the failed port is <port number> and it failed to
compare.
5 ALERT A test failure has occurred in a fibre-channel port. If this is reported at power-on,
it indicates a hardware problem in the unit. Contact technical support and report
the following information: the failed port is <port number> and it timed out.
6 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
a loopback test failure has occurred on virtual port <port number>.
7 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
SPI is not enabled on this chip.
8 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
a loopcheck test failure has occurred.
9 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
a sync error between chip <chip number> and <chip number> has occurred.
10 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
a transmit failure on chip <chip number> has occurred.
11 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
a receive failure on chip <chip number> has occurred.
12 ALERT A test failure has occurred on the internal SPI bus. This indicates a hardware
failure in the unit. Contact technical support and report the following information:
a router delivery failure on chip <chip number> has occurred.