Event Monitoring Service version A.04.20.11.04, A.04.20.23.04, and A.04.20.31.
© Copyright 2009 Hewlett-Packard Development Company, L.P Legal Notices Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained in this document is subject to change without notice.
Table of Contents 1 Event Monitoring Service Version A.04.20.11.04, A.04.20.23.04, and A.04.20.31.04 Release Notes..........................................................................................5 Announcement.......................................................................................................................................6 Product Overview...................................................................................................................................
List of Tables 1-1 1-2 1-3 4 EMS Hardware and HP-UX Compatibility.....................................................................................7 EMS Serviceguard Compatibility....................................................................................................8 EMS Product Filesets.....................................................................................................................
1 Event Monitoring Service Version A.04.20.11.04, A.04.20.23.04, and A.04.20.31.
Announcement Event Monitoring Service™ (EMS) version A.04.20.23.04 and A.04.20.31.04 is being released for use on the Integrity and PA-RISC platforms with the HP-UX 11i v2 and HP-UX 11i v3 operating system respectively. Event Monitoring Service (EMS) version A.04.20.11.04 is being released for use on the PA-RISC platforms with the HP-UX 11i v1 operating system. You can use EMS together with one or more EMS monitors to monitor various system resources.
• Management Information Base (MIB) Monitors - The following Management Information Base (MIB) monitors are provided with the EMS framework: — HA Cluster Monitor checks the status of clusters, nodes, packages, and services of Serviceguard. — HA Network Interface Monitor reports the status of LAN interfaces. — HA System Resource Monitor checks the number of users, the system load, and the amount of file system space. • The resls and resdata EMS utilities.
Table 1-1 EMS Hardware and HP-UX Compatibility (continued) EMS Version Compatible HP-UX Releases Compatible Hardware EMS A.04.20.23.01 HP-UX 11i v2 HP Integrity Server and HP 9000 Servers EMS A.04.20.31.01 HP-UX 11i v3 HP Integrity Server and HP 9000 Servers EMS A.04.20.11.02 HP-UX 11i v1 HP 9000 Servers EMS A.04.20.23.02 HP-UX 11i v2 HP Integrity Server and HP 9000 Servers EMS A.04.20.31.02 HP-UX 11i v3 HP Integrity Server and HP 9000 Servers EMS A.04.20.11.
Table 1-2 EMS Serviceguard Compatibility (continued) EMS Version HP-UX Release Serviceguard Version A.04.11 HP-UX 11i v2 (includes revisions for Serviceguard A.11.16.00 HP-UX 11i v2 May 2005 update) Serviceguard Extension for RAC (formerly known as Serviceguard OPS Edition) A.11.16.00 A.04.20 HP-UX 11i v2 Serviceguard A.11.16.00 Serviceguard Extension for RAC (formerly known as Serviceguard OPS Edition) A.11.16.00 A.04.20.11 HP-UX 11i v1 Serviceguard A.11.16.
Table 1-2 EMS Serviceguard Compatibility (continued) EMS Version HP-UX Release Serviceguard Version A.04.20.23.03 HP-UX 11i v2 Serviceguard A.11.16.00 Serviceguard Extension for RAC (formerly known as Serviceguard OPS Edition) A.11.16.00 A.04.20.31.03 HP-UX 11i v3 Serviceguard A.11.19 Serviceguard Extension for RAC (formerly known as Serviceguard OPS Edition) A.11.17.01 A.04.20.11.04 HP-UX 11i v1 Serviceguard A.11.16.
Memory Requirements To run EMS, memory space of approximately 3 MB is required on your system. Installing EMS EMS checks the resources for local systems only. EMS is most effective when installed and configured on all systems in your environment. EMS must be installed on each node that you want to monitor. EMS can be installed on a running system in a multiuser mode. NOTE: Updated monitors may have new status values that change the meaning of your monitoring requests.
While installing EMS, the installation process may modify /etc/services, /etc/inittab or /etc/inetd.conffiles. If the files are modified, a copy of the unmodified version is available in the /etc directory. For example, • • • /etc/inittab will be copied to /etc/ems_inittab.old /etc/services will be copied to /etc/services.old /etc/inetd.conf will be copied to /etc/inetd.conf.old Removing EMS You have to use the swremove utility or the Software Management tools in SAM to remove EMS.
Fixes in this Version The following defects are fixed in this release: • QXCR1000932860 – rm_log_init: fopen of file /etc/opt/resmon/log/client.log failed When an EMS client executes with non-root privilege, it is not able to open the /etc/opt/ resmon/log/client.log file due to insufficient privileges. EMS logs an error in the syslog stating that the privilege is insufficient. Until now it was not possible to determine which client caused this error to be logged.
NOTE: There will be no more updates to the user guides titled Using the Event Monitoring Service and Using High Availability Monitors. These documents were last updated in June 2007. The Using the Event Monitoring Service document is available at http://docs.hp.com/en/B7609-90049/ B7609-90049.pdf and the Using High Availability Monitors document is available at http:// docs.hp.com/en/B5736-90074/B5736-90074.pdf. Software Availability in Native Languages EMS does not provide native language support.