7 
HSD85021 
  Symptom: The internal server cannot communicate with itself through its public address. 
  Condition: This symptom might occur when NAT server is configured on the F5000-A5. 
HSD85020 
  Symptom: The maximum number of DNS mapping entries that F5000-A5 supports is less than 256. 
  Condition: None 
HSD78997 
  Symptom: The stack reboots after the F5000-A5 operates for a period and dynamic . 
  Condition: This symptom might occur when stateful failover is configured and the status of a dynamic 
aggregation group's member interfaces change frequently. 
HSD81025 
  Symptom: The F5000-A5 outputs an exception report message and reboots. 
  Condition: This symptom might occur when the default domain uses RADIUS authentication and a user 
logs in through the Web interface. 
HSD78486 
  Symptom: Traffic that flows in from one subinterface on a 2*10-GE interface module and flows out of 
another subinterface of the same interface is lost. 
  Condition: This symptom might occur when the F5000-A5 has operated for a long period and the CPU's 
receive buffer is full. 
HSD73095 
  Symptom: Traffic that flows in from one subinterface on a 2*10-GE interface module and flows out of 
another subinterface of the same interface is lost. 
  Condition: This symptom might occur when a lot of traffic needs to be forwarded between the two 
subinterfaces in a short period of time. 
HSD72095 
  Symptom: When the F5000-A5 has two 2*10-GE interface modules and the interfaces with the number 1 
both receive large amounts of packets, many packets are lost. 
  Condition: This symptom might occur when the F5000-A5 has two 2*10-GE interface modules and the 
interfaces with the number 1 both receive large amounts of packets. 
HSD71094 
  Symptom: The logic of an interface module stops forwarding when the traffic is continuously more than 
3G. 
  Condition: This symptom might occur when NAT and virtual firewall are configured and the traffic is 
continuously more than 3G. 
Resolved problems in 
SECPATH5000FA-CMW520-R3206P01 
None 