HP Firewall Series - HP AF5000-CMW520-R3206P22 Release Notes
33 
1.  Enter 4 in the File Control submenu. 
Deleting the file in cfa0:             
 'M' = MAIN  'B' = BACKUP  'S' = SECURE  'N/A' = NOT ASSIGNED   
============================================================================   
|NO. Size(B)  Time            Type  Name                     |   
|1 6647 May/17/2012 06:38:16 N/A cfa0:/system.xml |  
|2 4304  Aug/30/2010 15:06:00 N/A cfa0:/default_ca.cer     |  
|3 10485688 Feb/24/2012 06:50:14 N/A cfa0:/logfile/logfile.log    |   
|4 1410  May/17/2012 06:38:18 M cfa0:/startup.cfg     |  
|5 16969732 May/17/2012 07:53:22 M cfa0:/main.bin     |  
|6 4304  Apr/15/2010 20:42:32 N/A cfa0:/f5ka_ca.cer     |  
|7 1298  Apr/15/2010 20:42:42 N/A cfa0:/f5ka_local.cer     |  
|8 1411  Apr/15/2010 12:45:26 N/A cfa0:/default_local.cer    |   
|9 6396598  Jul/30/2010 14:55:10 N/A cfa0:/comware.map      |   
|10 470008  Nov/16/2010 14:59:58 N/A cfa0:/default.diag     |   
|11 19689129 Jul/30/2010 14:58:28 N/A cfa0:/ftp--pasv.cap    |   
|12 299 May/17/2010 16:07:06 N/A cfa0:/rsa.pub |   
|13 16256  May/11/2010 09:59:34 N/A cfa0:/meta_newemule.mtd    |   
|14 675 May/17/2010 20:24:56 N/A cfa0:/dsa.pub |   
|15 675   May/17/2010 21:01:46 N/A cfa0:/dsa-u200a.pub    |  
|16 24784  Jan/13/2011 19:57:56 N/A cfa0:/drv_diag.info     |  
|17 880 Aug/25/2010 11:21:38 N/A cfa0:/certnew.cer |  
|18 4308  Aug/30/2010 15:06:22 N/A cfa0:/1_ca.cer  |  
|19 2292  Aug/25/2010 11:22:54 N/A cfa0:/local.pfx |  
|20 2600  May/17/2011 17:18:36 N/A cfa0:/patchmain.binadcp    |   
|0   Exit                                                     |  
============================================================================   
Enter file No: 
2.  Enter the number of the file to delete. 
3.  When the following prompt appears, enter Y. 
The file you selected is cfa0:/logfile/~/logfile.log,Delete it? [Y/N]Y 
Deleting..............Done! 
Handling software upgrade failures 
If a software upgrade fails, the system runs the old software version. To handle a software failure:  
1.  Check the physical ports for a loose or incorrect connection, and verify the LEDs are correctly reflecting 
the port status. 
2.  If you are using the console port for file transfer, check the HyperTerminal settings (including the baud 
rate and data bits) for any wrong setting. 
3.  Check the file transfer settings: 
  If XMODEM is used, you must set the same baud rate for the terminal as for the console port.  
  If TFTP is used, you must enter the same server IP addresses, file name, and working directory as set 
on the TFTP server. 
  If FTP is used, you must enter the same FTP server IP address, source file name, working directory, 
and FTP username and password as set on the FTP server. 
4.  Check the FTP or TFTP server for any incorrect setting. 
5.  Check that the CF card has sufficient space for the upgrade file. 