HP Firewall Series - HP AF5000-CMW520-R3206P22 Release Notes

6
201310290163
Symptom;Device could not handle invalid SNMP packet and resulted in an exception.
Condition;Device received an invalid SNMP packet which had an oversize ContextName field.
P201310290149
Symptom:Device could not handle invalid SNMP packet and resulted in an exception.
Condition:Device received an invalid SNMP packet with overlong OID.
201310250241
Symptom:The master board experiences unexpected reboot or hung because of fatal error.
Condition: When system receives DHCP packet which contains abnormal option 82 field.
HSD107579
Symptom: After the device reboots, some link aggregation interfaces cannot forward traffic normally.
Condition: This symptom might occur when link aggregation interfaces and subinterfaces are
configured.
HSD107760
Symptom: After the device reboots, some service cards cannot forward traffic normally.
Condition: This symptom might occur after the device reboots.
Resolved problems in
SECPATH5000FA-CMW520-R3206P18
HSD105583
Symptom: Some temperature sensors read negative values.
Condition: This symptom might occur during a temperature test that is initiated at the CLI.
HSD105520
Symptom: The device reboots exceptionally.
Condition: This symptom might occur when the device has been up for a very long time and an error
occurs with messages between the CPU cores.
HSD86860
Symptom: The peer TE fiber optic interface cannot come up.
Condition: This symptom might occur when the F5000-A5 reboots or a transceiver is plugged in or
unplugged.
HSD86860
Symptom: VRRP status switchover occurs frequently on the F5000-A5.
Condition: This symptom might occur when VRRP is configured on the F5000-A5.
HSD89267
Symptom: GRE does not support fast forwarding and the forwarding performance is poor.
Condition: None
HSD85574
Symptom: The device reboots when an administrator uses SSH2 to log in.