IB4X-00 (ib) B.11.31.1403 HP Fabric Clustering System for InfiniBand Driver Release Notes
Table 1 HP-UX March 2014 (AR1403) Fixes (continued)
DescriptionDefect ID
A panic was seen with this stack trace:
panic+0x410
bad_kern_reference+0xa0
QXCR1001105291
$cold_pfault+0x2c0
vm_hndlr+0x1590
bubbleup+0x880
sohasavnode+0x40
sohasavnode+0x40
pstat_filedetails+0x450
$cold_pstat+0x590
syscall+0x5a0
System panic occurs at boot time when the kernel base page size is set to 64k. This issue is only
encountered with the AT083A HP Integrity 4X QDR CX-2 PCI-e G2 DP HCA. This is addressed
QXCR1001238388
in AT083A adapter firmware version 2.9.1530 which is included with the B.11.31.1403 IB4X-00
update. See the firmware upgrade process under “Known problems and limitations” (page 6).
This causes watchdog programs like MC/SG cmcld or Oracle CRS oprocd issue TOC due to a
delay on select/poll wakeup mechanism due to uncancelled timeout in IB. This is fixed to handle
the IB timeout functions to be executed quickly.
QXCR1001276288
This fixes a partial mapping error returned in rds_ib_xmit function which was not handled in the
code hence it caused the panic with the stack trace shown below. This issue applies to systems
without IO Page Directory hardware feature.
panic+0x410
bad_kern_reference+0xa0
QXCR1001307906
$cold_pfault+0x330
vm_hndlr+0x12f0
rds_ib_xmit+0xdc0
rds_send_xmit+0x540
rds_send_worker+0x90
rds_sendmsg+0x4d0
rds_pr_usrsend+0x2b0
sosend(inlined)
sendit(inlined)
$cold_sendmsg_common+0x320
sendmsg2+0x30
syscall+0x5c0
Table 2 HP-UX April 2013 (WEB1304) Fixes
DescriptionDefect ID
Sockets Direct Protocol (SDP) is being added in HPUX 11iv3. InfiniBand product is enhanced to
support SDP.
QXCR1001274737
Table 3 HP-UX March 2013 (AR1303) Fixes
DescriptionDefect ID
lssf command would always show the following error when the InfiniBand IB4X-00 product is
installed:
QXCR1001230551
# lssf -c /dev/rdisk/disk296 CRA REPORT SUMMARY Critical Resources Analysis encountered
internal ERRORs. The usage analysis could not be completed successfully ERROR: Some entries
from subsystem CRA library location failed to load. The subsystem CRA library location should
contain only CRA related shared libraries. Check for any file entries in the CRA library
location that are not valid shared libraries.
There was an issue with the way the CRA library was built. This issue has been fixed in this
release.
The following msg would appear in dmesg:QXCR1001238125
InfiniBand Card (HW path: 0/0/0/7/0/0/0) has wrong FW. Downloading FW.
4