AH400A/AH401A - HP PCIe 8Gb 1 port, 2 port, and 4Gb Fibre Channel QLogic HBAs using Linux, Windows, and HP-UX OS's Installation Guide, October 2008

Example 4-2 Example of Vital Product Data (VPD) after installation
# fcmsutil /dev/fcd5 vpd
V I T A L P R O D U C T D A T A
--------- ------------- -------
Product Description : HP 8Gb Dual Channel PCI-e 2.0 FC HBA
Part number : AJ764A or AH401A
Engineering Date Code : A-4832
Part Serial number : MXK8325000
Misc. Information : PW=15W
Mfd. Date : 4831
Mfd. ID : PX2810403-20 B
Check Sum : 0x4e
EFI version : 02.01
ROM Firmware version : 04.03.02
BIOS version : 02.02
FCODE version : 02.00
Asset Tag : NA
Example 4-3 Example of “ioscan” report after installation
# ioscan -fNH 0/4/0/0/0/1
Class I H/W Path Driver S/W State H/W Type Description
=====================================================================
fc 5 0/4/0/0/0/1 fcd CLAIMED INTERFACE HP AH401A 8Gb Dual Port PCIe Fibre Channel Adapter
(FC Port 2)
/dev/fcd5
tgtpath 0 0/4/0/0/0/1.0x50001fe1500d6f3a estp CLAIMED TGT_PATH fibre_channel
target served by fcd driver, target port id
0x10b00
lunpath 0 0/4/0/0/0/1.0x50001fe1500d6f3a.0x0 eslpt CLAIMEDLUN_PATH LUN path for ctl31
lunpath 2 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4001000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10257
lunpath 3 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4002000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10258
lunpath 4 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4003000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10259
lunpath 5 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4004000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10260
lunpath 6 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4005000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10261
lunpath 7 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4006000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10262
lunpath 8 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4007000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10263
lunpath 9 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4008000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10264
lunpath 10 0/4/0/0/0/1.0x50001fe1500d6f3a.0x4009000000000000 eslpt CLAIMEDLUN_PATH LUN path for disk10265
Verifying connectivity
Once the HP Fibre Channel Mass Storage software and hardware are installed and running, use
the following steps to verify connectivity:
1. Check the state of all Fibre Channel hardware and interfaces. Enter the ioscan command
and verify the Hardware State and the hw Interface state are CLAIMED.
If the Fibre Channel device file has not been created, enter the following commands:
# insf -e
# ioscan -f
Verifying connectivity 23