FibrChanl-00 (td) B.11.31 Fibre Channel Driver Release Notes

FibrChanl-00 HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver Release Notes
Verifying the FibrChanl-00 HP PCI Tachyon TL/TS/XL2 Fibre Channel Driver Installation
Chapter 1
9
Verifying the FibrChanl-00 HP PCI Tachyon TL/TS/XL2 Fibre Channel
Driver Installation
To verify whether the FibrChanl-00 HP PCI Tachyon TL/TS/XL2 Fibre Channel driver is installed
successfully on your system, complete the following steps:
Step 1. Enter the following command at the HP-UX prompt:
# swlist FibrChanl-00
Where:
FibrChanl-00 is the bundle name for the HP PCI Tachyon TL/TS/XL2 Fibre Channel driver.
If the HP PCI Tachyon TL/TS/XL2 Fibre Channel driver is installed successfully on the system, the
following message is displayed:
# Initializing...
# Contacting target "hostname"...
#
# Target: hostname:/
#
# FibrChanl-00 B.11.31 FibreChannel; HW=A6795A,A5158A
FibrChanl-00.FC-TACHYON-TL B.11.31 FibreChannel (TD) Driver
Step 2. Enter the following command at the HP-UX prompt:
# swverify FibrChanl-00
The following message is displayed:
Verification Succeeded
NOTE For information about errors encountered during the installation, removal, reinstallation, and
verification of the FibrChanl-00 HP PCI Tachyon TL/TS/XL2 Fibre Channel driver, see the
error log files at /var/adm/sw.