FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1 Release Notes Version Number B.11.11.16 HP Part Number: J6374-90072 Published: September 2008 Edition: 3.
Table of Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1 Overview...........................5 New and Changed Features in This Release..........................................................................................5 Defects Fixed in This Version.................................................................................................................5 Driver Versions................................................................................................
List of Tables 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 4 HP-UX 11i v1 September 2008 Fixes...............................................................................................5 HP-UX 11i v1 June 2008 Fixes.........................................................................................................5 HP-UX 11i v1 March 2008 Fixes......................................................................................................5 HP-UX 11i v1 December 2007 Fixes........................
This document provides information about the B.11.11.16 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1 Overview This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1 (version B.11.11.16) fixes the defects listed below. New and Changed Features in This Release This release contains only defect fixes. No new features have been introduced in this release.
Table 6 HP-UX 11i v1 April 2007 Fixes (continued) 8606479186 Fixed a problem where a path failover problem was seen with split cable disconnection from switch Rx. 8606479809 Fixed an ioscan hang which occured when a switch assigned the same domain and area (part of Nport ID) to the HBA and a target device. 8606467276 Fixed a problem by removing the unwanted diagnostics message, Device disappeared from Name Server GPN_FT, for initiator ports.
Table 11 HP-UX 11i v1 December 2005 Fixes (continued) 8606414032 Concurrent BDRs issued to the same device when both BDRs failed, the application that issued the commands hangs instead of timing out. Single BDRs repeatedly timed out due to a timer reset issue. Both of these have been corrected by changing the way that a failed BDR request is retried.
Table 13 HP-UX 11i v1 March 2005 Fixes (continued) 8606381755 vgexport/vgimport commands hang, a timeout function is needed 8606379689 “CLAIMED” message and ioscan description string should indicate HBA product number 8606391883 Incorrect information in fcdlist man page 8606381243 fcdlist.
Table 15 FibrChanl-01 (fcd) Driver Version History (continued) September 2006 B.11.11.09 (64-bit) June 2006 B.11.11.08 (64-bit) December 2005 B.11.11.07.01 (64-bit) September 2005 B.11.11.06 (64-bit) March 2005 B.11.11.05 (64-bit) December 2004 B.11.11.04 (64-bit) June 2004 B.11.11.03 (64-bit) December 2003 B.11.11.02 (64-bit) September 2003 B.11.11.
• • PHKL_31227 only needed if OLAR functionality is required; applies to all cards that have a bridge, including A9782A, A9784A, and AB465A PHSS_33918 needed for online diagnostics Driver bundles can be downloaded from the HP Software Depot at: http://www.software.hp.com Patches are available from either: http://www.software.hp.com or http://itresourcecenter.hp.com OnlineDiag is available at http://www.software.hp.
• • A9782A PCI-X 2Gb Fibre Channel and 1000Base-SX (Fiber) Gigabit Ethernet Combination Card A9784A PCI-X 2Gb Fibre Channel and 1000Base-T (Copper) Gigabit Ethernet Combination Card Related Information The latest documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1 is available at http://www.docs.hp.com, under the I/O Cards and Networking Software section in the Fibre Channel category.