FibrChanl-01 (fcd) B.11.11.16 Fibre Channel Mass Storage Driver Release Notes, Edition 3.0 (September 2008)

This document provides information about the B.11.11.16 release of the FibrChanl-01 (fcd) Fibre
Channel Mass Storage Driver for HP-UX 11i v1.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1
Overview
This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1
(version B.11.11.16) fixes the defects listed below.
New and Changed Features in This Release
This release contains only defect fixes. No new features have been introduced in this release.
Defects Fixed in This Version
The following defects are fixed in the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for
HP-UX 11i v1 September 2008 release. To view the entire details of each defect fix, refer to the
HP IT Resource Center at: http://forums1.itrc.hp.com/service/forums/home.do
Table 1 HP-UX 11i v1 September 2008 Fixes
DescriptionDefect ID
The sfp option is missing in fcddiag command. The sfp option which displays diagnostics
information from the card optical transceiver is added to /opt/fcms/bin/fcddiag
command.
QXCR1000803950
Table 2 HP-UX 11i v1 June 2008 Fixes
DescriptionDefect ID
SNIA HBA Library API HBA_GetFcpTargetMapping() is taking longer time to obtain
the FCP target mapping details if the hosts have many LUN's in NO_HW state. Fix has been
done to ignore the LUN's in NO_HW state from further processing.
QXCR1000810915
Table 3 HP-UX 11i v1 March 2008 Fixes
There are no defect fixes with this version
Table 4 HP-UX 11i v1 December 2007 Fixes
DescriptionDefect ID
fcd driver fails HBA initialization, when WEL bit is set in the NVRAM status register.CR: JAGag50013
Fixed an out-of-bounds array reference in the fcd SNIA library that caused core dumps.
Fixed an infinite loop condition in the fcd SNIA library.
CR: JAGag41528
Table 5 HP-UX 11i v1 September 2007 Fixes
DescriptionDefect ID
Panic due to cdio list getting corrupted
SR: 8606483960
Table 6 HP-UX 11i v1 April 2007 Fixes
DescriptionSR Number
Fixed a problem where a system hang was seen with the STK 9940B tape drive, when
connected to a 4 GB card.
8606476421
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v1 Overview 5