FibrChanl-01 (fcd) B.11.23.0807 Fibre Channel Mass Storage Driver Release Notes, Edition 2.0 (July 2008)

This document provides information about the B.11.23.0807 release of the FibrChanl-01 (fcd)
Fibre Channel Mass Storage Driver for HP-UX 11i v2.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2
Overview
This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2
(version B.11.23.0807) provides fixes for several defects.
New and Changed Features in This Release
New Features
The following features are new with the B.11.23.0807 version of the FibrChanl-01 (fcd) Fibre
Channel Mass Storage Driver for HP-UX 11i v2:
There are no new features with this release.
Defects Fixed in This Version
The following defect is fixed in the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for
HP-UX 11i v2 July 2008 release. To view the entire details of each defect fix, refer to the HP IT
Resource Center at: http://forums1.itrc.hp.com/service/forums/home.do
Table 1 HP-UX 11i v2 July 2008 Fixes
DescriptionDefect ID
SNIA HBA Library API HBA_GetFcpTargetMapping() is taking longer time to obtain the
FCP target mapping details if the hosts have many LUN's in NO_HW state. Fix has been done
to ignore the LUN's in NO_HW state from further processing
QXCR1000824321
Known Problems and Limitations
This section provides a list of known problems and limitations as known to HP at time of
publication. If workarounds are available, they are included.
EFI SEARCH Causes Boot to Fail on rx7640, rx8640, and sx2000 Superdome Server Systems
Running the SEARCH command at the EFI shell on rx7640, rx8640, and HP Integrity
Superdome/SX2000 server systems can cause the system to fail to boot through a Fibre
Channel HBA. rx7640 systems have a built-in SEARCH of slot 7. Affected 2Gb Fibre Channel
HBAs are: A6826A, A9782A, A9784A, and AB465A with EFI driver version 1.47 or earlier.
Affected 4Gb Fibre Channel HBAs are: AB378A and AB379A with EFI driver version 1.01.
The boot will fail with a message similar to the following:
Load of HP-UX
Primary Boot: 1.0.1/1/0/4/0.8.0.255.0.6.0 failed: Not Found
Corrective Action: A fix in the 2Gb/4Gb drivers has been released. The following steps will
resolve the issue:
1. Go to www.hp.com
2. Click Software & Driver Downloads.
3. In the white text box, type the name of the I/O card, such as A6826A.
4. Click the >> button.
5. Click the Cross Operating System button.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Overview 3