FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Version Number B.11.23.0903 HP Part Number: J6374-90079 Published: March 2009 Edition: 4.
Legal Notices © Copyright 2009 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Table of Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Overview...........................5 New and Changed Features in This Release..........................................................................................5 Defect Fixes.............................................................................................................................................5 Driver Versions.....................................................................................
List of Tables 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4 HP-UX 11i v2 March 2009 Fixes......................................................................................................5 HP-UX 11i v2 November 2008 Fixes...............................................................................................5 HP-UX 11i v2 September 2008 Fixes...............................................................................................5 HP-UX 11i v2 July 2008 Fixes.....................................
This document provides information about the B.11.23.0903 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Overview This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 (version B.11.23.0903) provides fixes for defects listed in Table 1. New and Changed Features in This Release There are no new features with this release.
Table 6 HP-UX 11i v2 September 2007 Fixes Defect ID Description SR: 8606487612 Fixed fcmsutil to accept the multiboot image with embedded firmware for flashing. SR: 8606483960 Panic due to cdio list getting corrupted Table 7 HP-UX 11i v2 April 2007 Fixes Defect ID Description SR: 8606468464 Fixed a problem where the system hung with an STK 9940B tape drive, when connected to a 4 Gb card.
Table 11 HP-UX 11i v2 December 2005 Fixes Defect ID Description SR: 8606413902 After installation of PHKL_30257 MO library drives in a 10-drive optical jukebox in SCC mode are not visible any more. By changing to indexed mapping 8 devices are visible, not all 10 drives. SR: 8606414341 A fix was applied to work around an ISP2312 controller issue with PCI-X memory writes when these memory writes are intermixed with partial split completions for PCI-X memory reads.
Table 13 HP-UX 11i v2 September 2004 Fixes Defect ID Description SR: 8606346794 SNIA HBA API GetPortStatistics() returns HBA_STATUS_ERROR SR: 8606348536 Under heavy IO load ioscan display LUNs behind certain devices as NO_HW SR: 8606351283 HP-UX Start-up status no longer fits on standard 80x24 console SR: 8606356804 Miscellaneous Fixes in IO path SR: 8606353003 Online Adapter ROM update command hangs SR: 8606364880 File descriptor leak in SNIA API for TargetMapping and PersistentBinding SR: 86
Channel HBA. rx7640 systems have a built-in SEARCH of slot 7. Affected 2Gb Fibre Channel HBAs are: A6826A, A9782A, A9784A, and AB465A with EFI driver version 1.47 or earlier. Affected 4Gb Fibre Channel HBAs are: AB378A and AB379A with EFI driver version 1.01. The boot will fail with a message similar to the following: Load of HP-UX Primary Boot: 1.0.1/1/0/4/0.8.0.255.0.6.0 failed: Not Found Corrective Action: A fix in the 2Gb/4Gb drivers has been released. The following steps will resolve the issue: 1. 2.
The delay observed during boot will be around N*21 seconds, where N is the number of unconnected fcd HBA ports. Corrective Action:Two workarounds are available for this issue: 1. 2. • Attach loop back hoods to all of the unconnected HBA ports. The loop back hoods will cause the unconnected HBA ports to come online in a private loop topology. Install the product bundle, mtIOScan, that enables boot time kernel threads. This will reduce the overall boot delay due to unconnected ports to 21 seconds.
Table 15 Recommended Firmware Versions (July 2008 or later) Fibre Channel Adapter EFI Driver Version Firmware Version AD193A/AD194A 1.05 or later 4.00.70 or later 403619–B21 1.09 or later 4.00.90 or later AD300A 1.05 or later 4.00.70 or later AB378A 1.05 or later 4.00.70 or later AB378B 1.05 or later 4.00.70 or later AB379A 1.05 or later 4.00.70 or later AB379B 1.05 or later 4.00.70 or later A6826A 1.49 or later 3.03.154 or later A9782A 1.49 or later 3.03.
Related Information The latest documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 is available at http://www.docs.hp.com, under the I/O Cards and Networking Software section in the Fibre Channel category. Available documents include: • • • • Support Guide: includes an adapter overview, installation details, adapter configuration, troubleshooting and maintenance information, additional features, and regulatory information.