FibrChanl-01 (fcd) B.11.23.0909 Fibre Channel Mass Storage Driver Release Notes, Edition 4.0 (September 2009)
Table 11 HP-UX 11i v2 December 2006 Fixes (continued)
DescriptionDefect ID
Fixed a problem in which the fcd driver reports a “Mailbox 0x69 Timeout.”SR: 8606454863
Fixed a problem in which firmware sometimes fails to bring the link up after a cable
disconnect / reconnect with 2 Gb fibre channel HBAs.
SR: 8606450588
Table 12 HP-UX 11i v2 September 2006 Fixes
DescriptionDefect ID
Resolved a problem that could cause a system panic when attempting an online update of
the fibre channel controller's firmware or EFI driver.
SR: 8606439680
Resolved a problem that could cause a 4Gb link to come up in public loop mode rather than
fabric mode.
SR: 8606451612
Resolved a problem that could cause a dump failure if there is a delay in obtaining the state
of the controller port.
SR: 8606447218
Table 13 HP-UX 11i v2 June 2006 Fixes
DescriptionDefect ID
Resolved a problem that could cause a system panic during system boot.SR: 8606440419
Table 14 HP-UX 11i v2 December 2005 Fixes
DescriptionDefect ID
After installation of PHKL_30257 MO library drives in a 10-drive optical jukebox in SCC
mode are not visible any more. By changing to indexed mapping 8 devices are visible, not
all 10 drives.
SR: 8606413902
A fix was applied to work around an ISP2312 controller issue with PCI-X memory writes
when these memory writes are intermixed with partial split completions for PCI-X memory
reads.
SR: 8606414341
Concurrent BDRs issued to the same device when both BDRs failed, the application that
issued the commands hangs instead of timing out. Single BDRs repeatedly timed out due
to a timer reset issue. Both of these have been corrected by changing the way that a failed
BDR request is retried.
SR: 8606414166
A turbulent link may result in I/O hang in the fibre channel controller firmware which
triggers an I/O timeout fatal error processing in the fibre channel driver. The fibre channel
controller firmware was modified to notify the driver once when multiple unsuccessful LIP
(Loop Initialization Primitive) sequences occur. This would help the driver to flow control
the I/Os and also to abort any I/Os that are already posted to the controller firmware, if the
LIP storm persists for over 10 seconds.
SR: 8606414869
Table 15 HP-UX 11i v2 March 2005 Fixes
DescriptionDefect ID
DMA related changes are needed in the driver for non- HP platform supportSR: 8606388386
Data corruption with A6826A and AB465A on rx1620SR: 8606388337
The fcd driver can now report when an unrecoverable hardware error occursSR: 8606377181
Calling HBA_SendCTPassThru() with a large ReqBufferSize may cause a panicSR: 8606380621
HBA_GetFcpTargetMapping() can affect normal access to tapeSR: 8606381090
VxVM interoperability issue with the fcd driver, due to first open time of 30 sec. or moreSR: 8606390263
Defect Fixes 7