FibrChanl-01 (fcd) B.11.23.1009 Fibre Channel Mass Storage Driver Release Notes, Edition 8.0 (September 2010)

This document provides information about the B.11.23.1009 release of the FibrChanl-01 (fcd)
Fibre Channel Mass Storage Driver for HP-UX 11i v2.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2
Overview
This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2
(version B.11.23.1009) provides fixes for defects listed in Table 1.
New and Changed Features in This Release
There are no new features with this release.
Defect Fixes
This section lists the defects fixed in the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver
for HP-UX 11i v2. Each table describes the defects fixed for a release. To view the entire details
of each defect fix, refer to the HP IT Resource Center at: http://forums1.itrc.hp.com/service/forums/
home.do
Table 1 HP-UX 11i v2 September 2010 Application Release (AR1009)Fixes
DescriptionDefect ID
The fcmsutil fails to update the ROM firmware for the 4Gb Qlogic card if the ROM
firmware version is 5 or greater. This issue is fixed.
QXCR1001021143
Table 2 HP-UX 11i v2 March 2010 (WEB1003)Fixes
DescriptionDefect ID
On a single-cpu vpar configuration when you execute the command fcmsutil
ns_query_port, the system throws a safety timer panic.
QXCR1000989456
Under certain circumstances the current FCD driver logic computes and writes the checksum
incorrectly. As a result, the FCD driver can potentially corrupt the card's NVRAM content.
The NVRAM content is corrupted if the OS Boot Mode is set to the default mode, that is,
the Windows/Linux/Other mode.
QXCR1000998430
Table 3 HP-UX 11i v2 November 2009 Fixes
DescriptionDefect ID
On HP-UX 11i v2, FibrChannel-01 bundle version 11.23.06 and later, the SNIA
HBA_GetFcpTargetMapping() API call made on a huge storage configuration takes a
long time to respond.
QXCR1000981981
Table 4 HP-UX 11i v2 September 2009 Fixes
DescriptionDefect ID
SNIA to support HBA_GetEventBuffer()QXCR1000902169
Table 5 HP-UX 11i v2 March 2009 Fixes
DescriptionDefect ID
The command /usr/sbin/ioscan -fnC disk displays NO_HW state for a LUN when
a volume group is activated on that LUN.
QXCR1000788939
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Overview 5