FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1003 HP Part Number: 5900-0484_e1.1 Published: October 2010 Edition: 1.
Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview..............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Known problems fixed in this version...........................................................................................
This document provides information about the B.11.31.1003 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1003) provides documentation error fixes. New and changed features in this release New features The following feature is new with the B.11.31.
Table 5 HP-UX March 2008 Fixes Defect ID Description QXCR1000754446 Added Symbolic Name support. Symbolic Names are user friendly names assigned to SAN components, and registered with the name server of an FC switch. FC switches display the registered symbolic names, which can be used by users to correlate SAN components across multiple servers and storage.
Addition of the card in progress... [ NOTE: Killing or otherwise aborting this olrad command may not cancel the Card Add operation.
• Update to Software Distributor is required If the updated or patched Software Distributor is not in place, a necessary reboot might not be performed during installation of the I/O drivers with DLKM functionality, which includes the FibrChanl-01 product. Corrective action: On systems prior to the HP-UX 11i v3 December 2007 OEUR, you must install Software Distributor patch PHCO_36530, or install the B.11.31.0709.308 or later revision of the Software Distributor product from http://docs.hp.
Corrective Action:The ioscan output can be returned to normal by either deleting the stale krm device files, or by starting krm, which will recreate the device files. • swlist does not indicate the mezzanine HBAs swlist does not indicate the Mezzanine HBAs, and cannot be added onto because of string size limitation. Corrective action: Refer to Hardware Requirements later in this document for more information.
Table 7 Recommended firmware versions (March 2010) (continued) Fibre channel adapter EFI driver version Firmware version 403619-B21 (with VC-FC boot support in BL860c) 1.09 or later 4.00.90 or later AD300A 1.05 or later 4.00.70 or later AB378A 1.05 or later 4.00.70 or later AB378B 1.05 or later 4.00.70 or later AB379A 1.05 or later 4.00.70 or later AB379B 1.05 or later 4.00.70 or later A6826A 1.49 or later 3.03.154 or later A9782A 1.49 or later 3.03.154 or later A9784A 1.
• AD193A/AD194A PCI-X 4Gb FC and 1000BT Combination Card • 403619-B21 PCIe Dual Port Mezzanine Fibre Channel Adapter • AD300A PCIe Dual Port 4Gb Fibre Channel Adapter • AB378B PCI-X Single Port 4Gb Fibre Channel Adapter • AB379B PCI-X Dual Port 4Gb Fibre Channel Adapter • AB378A PCI-X Single Port 4Gb Fibre Channel Adapter • AB379A PCI-X Dual Port 4Gb Fibre Channel Adapter • AB6826A PCI-X Dual Port 2 Gb/1 Gb Fibre Channel Adapter • A9782A PCI-X 2Gb Fibre Channel and 1000Base-SX (Fiber) Gigab