FibrChanl-01 (fcd) B.11.31.1003.01 Fibre Channel Mass Storage Driver Release Notes, Edition 4.1 (October 2010)
This document provides information about the B.11.31.1003.01 release of the FibrChanl-01 (fcd)
Fibre Channel Mass Storage Driver for HP-UX 11i v3.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3
overview
This release of the documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver
for HP-UX 11i v3 (version B.11.31.1003.01) provides documentation fixes.
New and changed features in this release
New features
The following feature is new with the B.11.31.1003.01 version of the FibrChanl-01 (fcd) Fibre
Channel Mass Storage Driver for HP-UX 11i v3:
• There are no new features for this release.
Known problems fixed in this version
The following issues have been fixed in the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver
for HP-UX 11i v3 March 2010 (WEB1003 and AR1003) releases. To view the entire details of
each issue fix, refer to the HP IT Resource Center at: http://forums1.itrc.hp.com/service/forums/
home.do
Table 1 HP-UX March 2010 (WEB1003) Fixes
DescriptionDefect ID
This fixes the issue where the SNIA returns HBA_STATUS_ERROR for HBA_SendCTPassThru
API call failure.
QXCR1000887704
This fixes a Serviceguard “safety timer” panic on a single-cpu vpar configuration, when the
command fcmsutil_ns_query_port is executed.
QXCR1001007011
This fixes the issue in the fcd driver that can intermittently result in a mailbox timeout fatal error.QXCR1000994941
This fixes the significant drop in I/O performance encountered after installing FCD B.11.31.0903
and later versions.
QXCR1001000800
Table 2 HP-UX March 2010 (AR1003) Fixes
DescriptionDefect ID
There are no fixes for the AR1003 release.N/A
Table 3 HP-UX January 2010 (WEB1001) Fixes
DescriptionDefect ID
This fixes the issue where the fcd driver corrupts the card's NVRAM content, due to the current
driver logic, which computes and writes the checksum incorrectly under certain circumstances.
The NVRAM corruption issue occurs only if the OS Boot Mode is set to [Windows/Linux/Other],
which is the default (i.e., manufacturing) setting.
QXCR1000979379
The fcd driver may cause a system panic with a data TLB fault. This problem, due to a potential
race condition, where the fcd driver receives an I/O completion interrupt from the card, while it
is still processing fatal errors, has been fixed.
QXCR1000991234
This fixes an issue where the fcd driver may panic during boot, when there is an 8 Gb Mezzanine
HBA configured in a blade server.
QXCR1000934838
This fixes the issue wheren SNIA does not report more than 500 luns per HBA.QXCR1000922032
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview 3