FibrChanl-01 (fcd) B.11.31.1109.01 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes
Table 8 HP-UX January 2010 (WEB1001) Fixes (continued)
DescriptionDefect ID
The NVRAM corruption issue occurs only if the OS Boot Mode is set to [Windows/Linux/Other],
which is the default (i.e., manufacturing) setting.
The fcd driver may cause a system panic with a data TLB fault. This problem, due to a potential
race condition, where the fcd driver receives an I/O completion interrupt from the card, while it
is still processing fatal errors, has been fixed.
QXCR1000991234
This fixes an issue where the fcd driver may panic during boot, when there is an 8 Gb Mezzanine
HBA configured in a blade server.
QXCR1000934838
This fixes the issue where SNIA does not report more than 500 luns per HBA.QXCR1000922032
fcd panics during system dump to an EMC device. This issue, caused by sense data handling,
has been fixed.
QXCR1000976060
This fixes a system hang which occurred after CPU deletion. The hang was caused by interrupt
migration handling in the fcd driver.
QXCR1000966390
Table 9 HP-UX September 2009 Fixes
DescriptionDefect ID
This fixes an issue where the fcd startup script removed the volume group directory in /dev/fcd,
followed by a number and vg name, such as /dev/fcd1dbvg03.
QXCR1000914828
This fixes the issue where fcd converted an Illegal Request into SCTL_INCOMPLETE. The fix
resolves the DS2405 open () performance issue, as well as the DS2405 firmware update failure
issue.
QXCR1000844402
Table 10 HP-UX March 2009 Fixes
DescriptionDefect ID
In HP-UX 11i v3, when you disable the legacy device-special files, the SNIA API
HBA_GetFcpTargetMapping() fails to report the remote targets correctly. This problem has been
fixed in the SNIA vendor library for the fcd driver.
QXCR1000876391
Table 11 HP-UX September 2008 Fixes
DescriptionDefect ID
There are no fixes for the September 2008 release.N/A
Table 12 HP-UX March 2008 Fixes
DescriptionDefect ID
Added Symbolic Name support. Symbolic Names are user friendly names assigned to SAN
components, and registered with the name server of an FC switch. FC switches display the
QXCR1000754446
registered symbolic names, which can be used by users to correlate SAN components across
multiple servers and storage.
Display fcd controller symbolic port and node names from HP-UX:
# /opt/fcms/bin/fcmsutil /dev/fcdl
fcd controller symbolic port and node names are displayed as N_Port Symbolic Port Name
and N_Port Symbolic Node Name.
Table 13 HP-UX September 2007 Fixes
DescriptionDefect ID
Enable DLKM for 11.31SR: 8606477107
Support online transceiver diagnostics – sfpSR: 8606479804
Known problems fixed in this version 5