FibrChanl-01 (fcd) B.11.31.1203.01 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes
Table 11 HP-UX September 2009 Fixes
DescriptionDefect ID
This fixes an issue where the fcd startup script removed the volume group directory in /dev/fcd,
followed by a number and vg name, such as /dev/fcd1dbvg03.
QXCR1000914828
This fixes the issue where fcd converted an Illegal Request into SCTL_INCOMPLETE. The fix
resolves the DS2405 open () performance issue, as well as the DS2405 firmware update failure
issue.
QXCR1000844402
Table 12 HP-UX March 2009 Fixes
DescriptionDefect ID
In HP-UX 11i v3, when you disable the legacy device-special files, the SNIA API
HBA_GetFcpTargetMapping() fails to report the remote targets correctly. This problem has been
fixed in the SNIA vendor library for the fcd driver.
QXCR1000876391
Table 13 HP-UX September 2008 Fixes
DescriptionDefect ID
There are no fixes for the September 2008 release.N/A
Table 14 HP-UX March 2008 Fixes
DescriptionDefect ID
Added Symbolic Name support. Symbolic Names are user friendly names assigned to SAN
components, and registered with the name server of an FC switch. FC switches display the
QXCR1000754446
registered symbolic names, which can be used by users to correlate SAN components across
multiple servers and storage.
Display fcd controller symbolic port and node names from HP-UX:
# /opt/fcms/bin/fcmsutil /dev/fcdl
fcd controller symbolic port and node names are displayed as N_Port Symbolic Port Name
and N_Port Symbolic Node Name.
Table 15 HP-UX September 2007 Fixes
DescriptionDefect ID
Enable DLKM for 11.31SR: 8606477107
Support online transceiver diagnostics – sfpSR: 8606479804
Avoid use of /tmp file for driver dumpsSR: 8606477715
Modify FCD dump driver to support > 2TB LUNsSR: 8606466124
Known problems and limitations
This section provides a list of known problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.
• Private Loop and Public Loop topology configuration support for Fibre Channel mezzanine
adapters
Private Loop and Public Loop topology configurations are not supported for Fibre Channel
mezzanine adapters on HP Integrity Blade servers in combination with the Fibre Channel (FC)
Pass Thru I/O Interconnect modules. These configurations can result in servers losing connection
to the Storage Area Network (SAN) during mezzanine adapter initialization, and SAN boot
may fail in such configurations.
6